首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
During extravehicular activities (EVA) outside the spacecraft, astronauts have to work under reduced pressure in a space suit. This pressure reduction induces the risk of decompression sickness (DCS) by the formation of gas bubbles from excess nitrogen dissolved in the organism by breathing air at normal pressure. Under laboratory conditions the gas bubbles moving in the blood stream can be detected by the non-invasive ultrasonic Doppler method. By early detection of excessive bubble formation the development of DCS symptoms may be prevented by early application of preventative measures. The method could also be useful when applied in the space suit in order to compare the results of laboratory tests with operational results, because there is a discrepancy according to the DCS risk of laboratory experiments and actual EVA missions, where no symptoms have been reported yet. A prototype Doppler sensor has been developed and implemented in the Russian Orlan suit. To investigate the feasibility of this method under simulated space conditions, the equipment has been used in a series of 12 thermovacuum chamber tests with suited subjects, where intravenous bubble formation was compared to unsuited control experiments. In more than 50% of the suited tests good Doppler recordings could be achieved. In some cases with unsatisfying results the signal could be improved by breathholding. Although the results do not yet allow any conclusion about a possible difference between suited and unsuited subjects due to the small number of tests performed, the method proved its feasibility for use in EVA suits and should be further developed to enhance the safety of EVA procedures.  相似文献   

2.
Ten subjects (from 27 to 41 years) have been participated in 32 experiments. They were decompressed from ground level to 40-35 kPa in altitude chamber when breathed 100% oxygen by mask and performed repeated cycles of exercises (3.0 Kcal/min). The intervals between decompressions were 3-5 days. Plasma lipid and erythrocyte membrane fatty acid composition was evaluated in the fasting venous blood before and immediately after hypobaric exposure. There were 7 cases decompression sickness (DCS). Venous gas bubbles (GB) were detected in 27 cases (84.4%). Any significant changes in the fatty acid composition of erythrocyte membranes and plasma didn't practically induce after the first decompression. However, by the beginning of the second decompression the total lipid level in erythrocyte membranes decreased from 54.6 mg% to 40.4 mg% in group with DCS symptoms and from 51.2 mg% to 35.2 mg% (p<0.05) without DCS symptoms. In group with DCS symptoms a tendency to increased level of saturated fatty acids in erythrocyte membranes (16:0, 18:0), the level of the polyunsaturated linoleic fatty acid (18:2) and arachidonic acid (20:4) tended to be decreased by the beginning of the second decompression. Insignificant changes in blood plasma fatty acid composition was observed in both groups. The obtained biochemical data that indicated the simulated extravehicular activity (EVA) condition is accompanied by the certain changes in the blood lipid metabolism, structural and functional state of erythrocyte membranes, which are reversible. The most pronounced changes are found in subjects with DCS symptoms.  相似文献   

3.
The ultrasonic bubble detection technique has been used as a versatile tool in the investigation of hypobaric decompression procedures for the last two decades. However, this method can only detect relatively large bubbles > 30-50 micrometers (usually in venous blood) and not the very first stages of bubble formation. Recently, the mechanical oscillator technique has been applied in air diving trials in order to detect small blood density changes due to hypothetical fluid shifts. However, sharp density drops were found in the decompression process, and these have been attributed to gas bubble formation. In this study, this method was applied together with Doppler controls to a series of altitude decompressions to 300 and 500 hPa, which represents the range of EVA operational pressures currently used or planned. Six subjects participated in both series; the oscillator sample tube could be pressurized. By the application of pressure on a blood sample containing questionable gas bubbles, these are reduced in volume, like in recompression therapy, and thus the density of the sample is increased. This effect has been shown in all 6 subjects undergoing decompression to 300 hPa, whereas in the 500 hPa series only 3 out of 6 subjects corresponded with gas phase formation immediately after decompression. Typically, Doppler bubbles appeared only after some latency time between 20 and 60 min; after this time, the density effect had nearly vanished. It is concluded that the mechanical oscillator technique represents a complementary research instrument to the Doppler method, because it is able to deliver a quantitative resolution of the early stage of gas phase formation.  相似文献   

4.
Kumar KV  Waligora JM 《Acta Astronautica》1995,36(8-12):589-593
Doppler ultrasound is frequently used for monitoring circulating microbubbles during decompression to assess the symptoms of Decompression Sickness (DCS). This analysis was carried out to evaluate its effectiveness for screening symptoms of DCS during simulated extravehicular activities (EVA). The information from various hypobaric chamber studies carried out at the NASA Johnson Space Center, Houston, TX was used in this analysis (n = 516). The circulating microbubbles were detected in the precordial area in 42% (218/516), and symptoms were reported in 16% (81/516) of these exposures. The accuracy of Doppler-detectable bubbles (Spencer grades) on all symptoms of DCS was examined by calculating measures of sensitivity and specificity. The efficacy of Doppler as a screening device was examined by calculating their positive predictive value (PPV) and negative predictive value (NPV). The results of these analyses indicated that the sensitivity of Doppler decreased, and the PPV increased with higher Spencer grades. However, the likelihood of detecting true negative cases (NPV) was consistently higher with all bubble grades. Due to the high false-positive rate and low prior probabilities of the risk of DCS, Doppler was found to be more useful to identify those who did not develop DCS, than to detect positive cases of DCS in the simulated EVA exposures.  相似文献   

5.
Extra-vehicular activity (EVA) has a significant role during extended space flights. It demonstrates that humans can survive and perform useful work outside the Orbital Space Stations (OSS) while wearing protective space suits (SS). When the International Space Station 'Alpha' (ISSA) is fully operational, EVA assembly, installation, maintenance and repair operations will become an everyday repetitive work activity in space. It needs new ergonomic evaluation of the work/rest schedule for an increasing of the labor amount per EVA hour. The metabolism assessment is a helpful method to control the productivity of the EVA astronaut and to optimize the work/rest regime. Three following methods were used in Russia to estimate real-time metabolic rates during EVA: 1. Oxygen consumption, computed from the pressure drop in a high pressure bottle per unit time (with actual thermodynamic oxygen properties under high pressure and oxygen leakage taken into account). 2. Carbon dioxide production, computed from CO2 concentration at the contaminant control cartridge and gas flow rate in the life support subsystem closed loop (nominal mode) or gas leakage in the SS open loop (emergency mode). 3. Heat removal, computed from the difference between the temperatures of coolant water or gas and its flow rate in a unit of time (with assumed humidity and wet oxygen state taken into account). Comparison of heat removal values with metabolic rates enables us to determine the thermal balance during an operative medical control of EVA at "Salyut-6", "Salyut-7" and "Mir" OSS. Complex analysis of metabolism, body temperature and heat rate supports a differential diagnosis between emotional and thermal components of stress during EVA. It gives a prognosis of human homeostasis during EVA. Available information has been acquired into an EVA data base which is an effective tool for ergonomical optimization.  相似文献   

6.
The aim of this paper is to review the main results of medical support of 78 two-person extravehicular activities (EVAs) which have been conducted in the Mir Space Program. Thirty-six male crewmembers participated in these EVAs. Maximum length of a space walk was equal to 7 h 14 min. The total duration of all space walks reached 717.1 man-hours. The maximum frequency of EVA's execution was 10 per year. Most of the EVAs (67) have been performed at mission elapsed time ranging from 31 to 180 days. The oxygen atmosphere of the Orlan space suit with a pressure of 40 kPa in combination with the normobaric cabin environment and a short (30 min) oxygen prebreathe protocol have minimized the risk of decompression sickness (DCS). There has been no incidence of DCS during performed EVAs. At the peak activity, metabolic rates and heart rates increased up to 9.9-13 kcal/min and 150-174 min-1, respectively. The medical problems have centred on feeling of moderate overcooling during a rest period in a shadow after the high physical loads, episodes with tachycardia accompanied by cardiac rhythm disorders at the moments of emotional stress, pains in the muscles and general fatigue after the end of a hard EVA. All of the EVAs have been completed safely.  相似文献   

7.
A 10.2 psi staged-decompression schedule or a 4-hour preoxygenation at 14.7 psi is required prior to extravehicular activity (EVA) to reduce decompression sickness (DCS) risk. Results of recent research at the Air Force Research Laboratory (AFRL) showed that a 1-hour resting preoxygenation followed by a 4-hour, 4.3 psi exposure resulted in 77% DCS risk (N=26), while the same profile beginning with 10 min of exercise at 75% of VO2peak during preoxygenation reduced the DCS risk to 42% (P<.03; N=26). A 4-hour preoxygenation without exercise followed by the 4.3 psi exposure resulted in 47% DCS risk (N=30). The 1-hour preoxygenation with exercise and the 4-hour preoxygenation without exercise results were not significantly different. Elimination of either 3 hours of preoxygenation or 12 hours of staged-decompression are compelling reasons to consider incorporation of exercise-enhanced preoxygenation.  相似文献   

8.
ISS construction and Mars exploration require extensive extravehicular activity (EVA), exposing crewmembers to increased decompression sickness risk. Improved bubble detection technologies could help increase EVA efficiency and safety. Creare Inc. has developed a bubble detection and sizing instrument using dual-frequency ultrasound. The device emits “pump” and “image” signals at two frequencies. The low-frequency pump signal causes an appropriately-sized bubble to resonate. When the image frequency hits a resonating bubble, mixing signals are returned at the sum and difference of the two frequencies. To test the feasibility of transcutaneous intravascular detection, intravascular bubbles in anesthetized swine were produced using agitated saline and decompression stress. Ultrasonic transducers on the chest provided the two frequencies. Mixing signals were detected transthoracically in the right atrium using both methods. A histogram of estimated bubble sizes could be constructed. Bubbles can be detected and sized transthoracically in the right atrium using dual-frequency ultrasound.  相似文献   

9.
Current projects of manned missions to Mars are aimed to their realization in the second-third decades of this century. The purpose of this paper is to determine and review the main biomedical problems, that require a first and foremost decision for safety support of extravehicular activity (EVA) carried out by crewmembers of the Mars expedition. To a number of such problems the authors of the paper attribute a creation of adequate EVA equipment intended, first, for assembly of interplanetary spacecraft on the Earth orbit, performance of maintenance operations and scientific researches on the external surface of spacecraft during interplanetary flight and, secondly, for work on the Mars surface. New generation of space suits with low weight, high mobility and acceptable risk of decompression sickness must be as a central component of EVA equipment. The program for preparation to a Mars expedition also has to include special investigations in order to design the means and methods for a reliable protection of crew against space radiation, to elaborate the approach to medical monitoring and primary medical care during autonomous space mission, to maintain good health condition of crewmembers during EVA under the Mars gravity (0.38 g) after super long-term flight in weightlessness.  相似文献   

10.
The current status of European EVA (extravehicular activity) plans is reviewed. The major difference to already existing EVA scenarios in U.S.A. and Soviet Union consists in the adoption of a higher suit pressure, namely 500 hPa. The results of a study concerned with the physiological consequences of this adoption are presented, including recommendations for protective procedures and their necessary experimental validation. A certain discrepancy between laboratory experimental decompression data and EVA operational results is discussed, leading to the identification of several items which may influence space decompression. Microgravity and the influence of the space suit itself are most likely factors in the explanation of this discrepancy, and both experimental procedures and technological developments are proposed to clarify their role for the future design of EVA procedures.  相似文献   

11.
12.
A feasibility study in 1992 showed the benefits of a common European Russian space suit development, EVA Suit 2000, replacing the Russian space suit Orlan-DMA and the planned European Hermes EVA space suit at the turn of the century. This EVA Suit 2000 is a joint development initiated by the European Space Agency (ESA) and the Russian Space Agency (RKA). The main objectives of this development program are: first utilization aboard the Russian Space Station MIR-2; performance improvement with respect to current operational suits; development cost reduction. Russian experience gained with the present extravehicular activity (EVA) suit on the MIR Space Station and extensive application of European Technologies will be needed to achieve these ambitious goals. This paper presents the current status of the development activities, the space suit system design and concentrates in more detail on life support aspects. Specific subjects addressed will include the overall life support conceptual architecture, design features, crew comfort and operational considerations.  相似文献   

13.
For the European manned space activities an EVA space suit system was being developed in the frame of the Hermes Space Vehicle Programme of the European Space Agency (ESA). The space suit was to serve the needs for all relevant extravehicular activities for the Hermes Columbus operations planned to begin in 2004. For the present Russian manned space programme the relevant EVAs are performed by the Orlan-DMA semi-rigid space suit. The origin of its development reaches back to the 1970s and has since been adapted to cover the needs for extravehicular activities on Salyut and MIR until today. The latest modification of the space suit, which guaranteed its completely self-contained operation, was made in 1988. However, Russian specialists considered it necessary to start developing an EVA space suit of a new generation, which would have improved performance and would cover the needs by the turn of the century and into the beginning of the next century. Potentially these two suit developments could have a lot in common based on similarities in present concepts. As future manned space activities become more and more an international effort, a safe and reliable interoperability of the different space suit systems is required. Based on the results of the Munich Minister Conference in 1991, the European Space Agency and the Russian Space Agency agreed to initiate a requirements analysis and conceptual design study to determine the feasibility of a joint space suit development, EVA 2000. The design philosophy for the EVA 2000 study was oriented on a space suit system design of: space suit commonality and interoperability; increased crew productivity and safety; increase in useful life and reduced maintainability; reduced development and production cost. The EVA 2000 feasibility study was performed in 1992, and with the positive conclusions for EVA 2000, this approach became the new joint European Russian EVA Suit 2000 Development Programme. This paper gives an overview of the results of the feasibility study and presents the joint requirements and the proposed design concept of a jointly developed European Russian space suit.  相似文献   

14.
《Acta Astronautica》2008,62(11-12):1002-1009
Under weightlessness, the effect of harmonic vibrations can easily induce average motions in fluids with density inhomogeneities. We will consider more particularly pure fluids near their gas–liquid critical point, where the temperature variation of all important parameters (e.g. interfacial tension, density difference) follows universal, scaling laws. We will thus study, below the critical point, the ordering of the gas–liquid interfaces (at equilibrium and during the phase separation) and, above the critical point, some thermovibrational instabilities. These studies have been performed in the Russian MIR station and in the MiniTexus and Maxus rockets of ESA and under magnetic compensation of gravity on earth.  相似文献   

15.
The European spacesuit system (ESSS) initiated by the European Space Agency (ESA) in the late 1980s had many similarities with the Soviet/Russian ORLAN spacesuit system, due to the Hermes system requirements. First, direct contacts in 1989 permitted closer comparison of the two suit systems, and soon the ORLAN manufacturer Zvezda could be contracted as support to the European spacesuit team. In particular, the suit enclosure design and predevelopment testing and operational analysis were performed in close cooperation between Zvezda and the European team under Dornier.

With the changing system requirements and a closer cooperation between ESA and the new Russian Space Agency (RKA) a new joint spaceplane/stations mission scenario came about. This scenario could be served by one spacesuit system, EVA SUIT 2000, which was to be jointly developed by a team headed by Zvezda and Dornier for ESA and RKA. ORLAN-DMA and ESSS experience and hardware were the initial platforms for these activities to create a new generation spacesuits for the Mir 2 and later the ISSs.

A suit demonstrator was manufactured and tested by the end of 1994 when ESA stopped its spacesuit development activities and the joint EVA SUIT 2000 project was terminated. However, many of the features designed, manufactured and tested for the EVA SUIT 2000 were then implemented by Zvezda in the new Russian spacesuit system ORLAN-M, now in full operation onboard the ISS.  相似文献   


16.
The experience in operation and improving the Orlan-type space suits   总被引:1,自引:0,他引:1  
Nowadays significant experience has been gained in Russia concerning extravehicular activity (EVA) with cosmonauts wearing a semi-rigid space suit of the "Orlan" type. The conditions for the cosmonauts' vital activities, the operational and ergonomic features of the space suit and its reliability are the most critical factors defining the efficiency of the scheduled operation to be performed by the astronaut and his safety. As the missions performed by the cosmonauts during EVA become more and more elaborate, the requirements for EVA space suits and their systems become more and more demanding, resulting in their consistent advancement. This paper provides certain results of the space suit's operation and analysis of its major problems as applied to the Salyut and MIR orbiting stations. The modification steps of the space suit in the course of operation (Orlan-D, Orlan-DM, Orlan-DMA) and its specific features are presented. The concept of the suited cosmonauts' safety is described as well as trends for future space suit improvements.  相似文献   

17.
An Extravehicular Mobility Unit is a closed and isolated environment that protects the astronaut from exposure to space environment. Eighty-four percent of the possible hardware failures occurring during Extravehicular Activity (EVA) would result in an abort of the EVA. Fifty-two percent of these failure modes would result in a loss of a critical life support function and directly compromise crew safety. Crew safety is not, however, limited to controlling hardware failures. Safety can be compromised by improper in-flight servicing or induced by interfacing equipment during EVA related activity. This paper addresses these potential hazard sources and approaches used to enhance equipment reliability and astronaut safety.  相似文献   

18.
Design to safety: experience and plans of the Russian space suit programme   总被引:1,自引:0,他引:1  
The paper presents the analysis of the Russian experience gained in the operations of Salyut-6, 7 and Mir orbital stations. The main factors determining their effectiveness and safety are considered and the main requirements to the EVA suit, as the most important tool for the EVA, are formulated.  相似文献   

19.
In the recent years the Russian Orlan-M space suits have been improved as applied to their operational requirements for the ISS. A special attention is paid to enhancement of EVA crew efficiency and safety. The paper considers the main problems regarding specific features of the Russian space suit operation in the ISS, and analyses measures on their solution. In particular, the problems associated with the following are considered: enhancement of the anthropometric range for the EVA crewmembers; use of some US EMU elements and unified NASA equipment elements; Orlan-M operation support in the wide range of the ISS thermal conditions; use of Simplified Aid For Extravehicular activity Rescue (SAFER) designed as a self-rescue device, which will be used for an EVA crewmember return in the event that he (she) breaks away inadvertently from the ISS surface. The paper states the main space suit differences with reference to solution of the above problems. The paper presents briefly the design of space suit arms developed for crewmembers with small anthropometric parameters, as well as peculiarities and test results for the gloves with enhanced thermal protection. Measures on further space suit development with the purpose to improve its performances are considered.  相似文献   

20.
Several studies in animals over the past decade have shown that prolonged exposures to pressures within the range 226 mm Hg to 160 mm Hg (30,000 to 37,500 ft) are likely to lead to brain damage. This often results in neurological and behavioural disturbance, which may be subtle and reversible or gross and ultimately fatal. The appearance of these impairments is often delayed until several hours or even days after exposure. Immediate survival does not necessarily ensure recovery. In contrast, decompression to pressures below 160 mm Hg or above 226 mm Hg are unlikely to have adverse effects if the exposure is survived. The most probable outcomes of such decompressions are death or uneventful recovery.  相似文献   