首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   13篇
  免费   0篇
航空   4篇
航天技术   9篇
  2020年   1篇
  2010年   1篇
  2009年   1篇
  2008年   4篇
  2004年   2篇
  1998年   1篇
  1995年   1篇
  1992年   1篇
  1983年   1篇
排序方式: 共有13条查询结果,搜索用时 578 毫秒
1.
SN 1006 is one of the supernova remnants (SNRs) with relatively low-temperature electrons, considering the young age of just 1000 years. We carried out SN 1006 mapping observations with the X-ray Imaging Spectrometers (XIS) and the Hard X-ray Detector (HXD) onboard Suzaku, the fifth Japanese X-ray satellite. Thanks to the excellent spectral resolution of XIS in the soft X-ray band, H-like and He-like oxygen emission lines were clearly detected, and we could make a map of the line intensity, and as well as a flux and the photon index of nonthermal component. We found that these parameters have spatial dependences from region to region in the SNR; the north region is bright in nonthermal, while dim in thermal; the east region is bright in both nonthermal and thermal; the inner region shows dim nonthermal and bright thermal emission. The photon index is the smallest in the north region.  相似文献   
2.
Feasibility studies on a multiband communication satellite antenna system and the key technologies involved in devising this system are described. The proposed multiband communication satellite utilizes four frequency bands: Ka (30/20 GHz), Ku (14/12 GHz), C (6/4 GHz), and S (2.6/2.5 GHz). It has six beam configurations, three multibeam and three shaped-beam. The following key technologies are presented: (1) a low-loss frequency selective subreflector (FSR) for compact feeds, (2) a low-loss and broadband frequency selective surface (FSS), and (3) a highly accurate and reliable mesh reflector  相似文献   
3.
The performance of an adaptive moving target indicator (MTI), which employs a Wiener predictor by means of a transversal filter, is discussed, taking into consideration the effect of the form of the clutter covariance matrix on the MTI performance. It is emphasized that the main tap position in the transversal filter is an important factor which provides degrees of freedom in the clutter covariance matrix to improve the MTI performance. Calculation results show that by exploiting these degrees of freedom, excellent performance is feasible, in particular shorter transient response.  相似文献   
4.
Cometary dust trails were first observed by IRAS; they are widely known to be the origins of meteoric showers. A new window has been opened for the study of dust trails, using ground-based observations. We succeeded in obtaining direct images of the 22P/Kopff dust trail with the Kiso 1.05-m Schmidt telescope. Following this initial success, we have continued to perform a dust trail survey at Kiso. As a result of this survey, we have detected dust trails along the orbit of six periodic comets, between February 2002 and March 2004. The optical depth of these dust trails are 10−9 to 10−8, which is consistent with IRAS measurements. In this paper, we describe the observations and data reduction procedures, and report the brief result obtained between February 2002 and March 2004.  相似文献   
5.
Stüeken  E. E.  Som  S. M.  Claire  M.  Rugheimer  S.  Scherf  M.  Sproß  L.  Tosi  N.  Ueno  Y.  Lammer  H. 《Space Science Reviews》2020,216(3):1-17
Space Science Reviews - The Ionospheric Connection Explorer (ICON) mission makes measurements in near-Earth space that provide knowledge of the state of the ionosphere. From the vantage of...  相似文献   
6.
We propose a new type of wide band X-ray imaging spectrometer as a focal plane detector of the super mirror onboard on future X-ray missions including post Astro-E2. This camera is realized by the hybrid of back illumination CCDs and a back supportless CCD for 0.05–10 keV band, and a Micro Pixel Gas Chamber detecting X-rays at 10–80 keV.  相似文献   
7.
Particle motion in a volatile droplet on a solid surface, especially the behavior of particles depositing in the vicinity of a solid–liquid–gas boundary line (contact line) is focused. This phenomenon is called the ‘coffee stain problem’. Motion and deposition of the particles suspended in distilled water droplets and distilled water–ethanol mixture droplets are discussed. The spatio-temporal particle motion is analyzed by the three-dimensional particle tracking velocimetry (3D PTV). A discussion of the morphology of the particles stuck to the solid surface after the dryout of the droplet is also given.  相似文献   
8.
Several ground-based observations of the Venus 1.27-μm O2 airglow were carried out from 2002 to 2005. Spectral image cubes were taken with the Okayama Astrophysical Observatory/infrared imaging spectrometer (superOASIS), the Gunma Astronomical Observatory/Cassegrain Near-Infrared Camera and NASA’s Infrared Telescope Facility/cryogenic echelle spectrograph (CSHELL). The brightest airglow features were found at around the anti-solar point, which is in agreement with previous studies. We derived the rotational temperature distributions on the nightside hemisphere from observed airglow spectra. The temperature shows a weak positive correlation with the airglow intensity. The result indicates the bright region is heated chemically and/or dynamically, and supports the existing scenario for the Venus O2 airglow. That is, the airglow is excited by the descending oxygen transported from the dayside.  相似文献   
9.
We have built a prototype of thin-foil substrates for the future mission with a large X-ray telescope. In future X-ray missions, the understanding of the early universe to reveal the evolution of the universe will become an important issue. For this purpose, large telescopes with high-spatial resolution up to 10′′ are required. Using a stamping die with high accuracy, we have successfully press-formed thin-foil substrates into an almost accurate form of the Wolter type-I optics, which reflect X-rays twice with their confocal paraboloidal and hyperboloidal reflectors. The accuracy of the shape has reached to <15 μm.  相似文献   
10.
Three-dimensional (3-D) velocity field reconstruction of oscillatory thermocapillary convections in a half-zone liquid bridge with a radius of O (1 mm) was carried out by applying 3-D particle tracking velocimetry (PTV). Simultaneous observation of the particles suspended in the bridge by two CCD cameras was carried out by placing a small cubic beam splitter above a transparent top rod. The reconstruction of the 3-D trajectories and the velocity fields of the particles in the several types of oscillatory-flow regimes were conducted successfully for sufficiently long period without losing particle tracking. With this application the present authors conducted a series of experiments focusing upon the collapse and re-formation process of the PAS by mechanically disturbing fully developed PAS.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号