Measurement of mass diffusion coefficients of O_2 in aviation fuel through digital holographic interferometry
Authors:Chaoyue LI  Weihua LIU  Xiaotian PENG  Lei SHAO  Shiyu FENG
Abstract:The experimental apparatus to measure the mass diffusion coefficients of O2 in aviation fuel was constructed based on the digital holographic interferometry method. The theory of mass diffusion coefficient and interference image processing were introduced in detail. The accuracy of the experiment was verified by measuring the mass diffusion coefficient of 0.33 mol/L KCl in aqueous solution at 298.15 K. The mass diffusion coefficients of O_2 in RP3 and RP5 aviation fuels were measured at temperature from 278.15 K to 333.15 K, and the Arrhenius equation was employed to fit the experimental data. In terms of the Stokes-Einstein equation, the viscosities of these two aviation fuels were tested to estimate the correlation among mass diffusion coefficient, viscosity and temperature. A uniform polynomial calculation correlation was proposed to predict the mass diffusion coefficients of O_2 in both RP3 and RP5 aviation fuels, and its accuracy is considerably higher than that of the Stokes-Einstein equation.
Keywords:Corresponding author    Aviation fuel  Diffusion coefficients  Digital holographic interferometry  Oxygen  Viscosity