排序方式: 共有2条查询结果,搜索用时 0 毫秒
1
1.
Introduction
The current U.S. extravehicular activity (EVA) suit in space includes liquid cooling and ventilation garment (LCVG) to control thermal condition. Tubes knitted in LCVG for flowing water interrupt evaporation of perspiration, and astronauts feel discomfort. In the present study, we hypothesized that a self-perspiration garment would effectively lower the skin temperature without raising humidity in the garment. Thus, we developed and examined the effects of the garment.Methods
Eight healthy subjects were studied with a cyclic ergometer of 30, 60 90 and 120 W loading for 3 min each. Skin temperature and humidity on the back were measured continuously. Subjects wore and tested three types of garments i.e., a spandex wear without any cooling device (Normal), a simulated LCVG (s-LCVG) or the spandex wear knitted a vinyl tube for flowing water, and the spandex wear with a tube, which flows water and self-perspiration with oozing water for evaporative cooling (SPEC).Results
All measurements were reached to steady state 2–3 min after the setting. The s-LCVG decreased skin temperature 0.39±0.14 °C during 12 min of cooling. With SPEC, skin temperature did not decrease significantly until 6–9 min after starting the cooling. However, the temperature decreased rapidly and significantly after that, and finally decreased 1.59±0.32 °C. Humidity in the SPEC was significantly lower than that in s-LCVG.Discussion
SPEC was effective for lowering skin temperature without raising humidity in the garment. The concept is expected to use as a better cooling system during EVA. 相似文献2.
目前X射线检测存在检测底片难于长时间保存、对操作人员依赖性强等不足,底片检测信息处理智能化水平较低。随着搅拌摩擦焊、激光焊等新方法的应用,制造业数字化车间的建设,对缺陷检测、质量检测信息的有效保存、处理也提出了更高的要求。为解决轨道车辆车体焊接结构内部缺陷检测可视化、自动化的需求,研发高质量的X射线检测底片扫描技术、先进的信息处理技术,开发X射线检测底片的数字化及自动化评定技术,实现底片有效信息的无损数字化,底片缺陷自动搜寻、测量与分类,研发国内首套高速列车射线底片智能化评定系统,提升X射线检测技术的信息化、自动化水平,实现底片自动化评定。相关技术可向航空航天产品进行推广。 相似文献