首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   36篇
  免费   0篇
航空   7篇
航天技术   23篇
综合类   1篇
航天   5篇
  2021年   2篇
  2019年   2篇
  2018年   1篇
  2013年   3篇
  2011年   2篇
  2010年   11篇
  2009年   3篇
  2008年   1篇
  2007年   1篇
  2004年   1篇
  2003年   2篇
  1998年   1篇
  1995年   1篇
  1993年   1篇
  1992年   1篇
  1986年   1篇
  1981年   1篇
  1978年   1篇
排序方式: 共有36条查询结果,搜索用时 28 毫秒
1.
Lake water height is a key variable in water cycle and climate change studies, which is achievable using satellite altimetry constellation. A method based on data processing of altimetry from several satellites has been developed to interpolate mean lake surface (MLS) over a set of 22 big lakes distributed on the Earth. It has been applied on nadir radar altimeters in Low Resolution Mode (LRM: Jason-3, Saral/AltiKa, CryoSat-2) in Synthetic Aperture Radar (SAR) mode (Sentinel-3A), and in SAR interferometric (SARin) mode (CryoSat-2), and on laser altimetry (ICESat). Validation of the method has been performed using a set of kinematic GPS height profiles from 18 field campaigns over the lake Issykkul, by comparison of altimetry’s height at crossover points for the other lakes and using the laser altimetry on ICESat-2 mission. The precision reached ranges from 3 to 7 cm RMS (Root Mean Square) depending on the lakes. Currently, lake water level inferred from satellite altimetry is provided with respect to an ellipsoid. Ellipsoidal heights are converted into orthométric heights using geoid models interpolated along the satellite tracks. These global geoid models were inferred from geodetic satellite missions coupled with absolute and regional anomaly gravity data sets spread over the Earth. However, the spatial resolution of the current geoid models does not allow capturing short wavelength undulations that may reach decimeters in mountaineering regions or for rift lakes (Baikal, Issykkul, Malawi, Tanganika). We interpolate in this work the geoid height anomalies with three recent geoid models, the EGM2008, XGM2016 and EIGEN-6C4d, and compare them with the Mean Surface of 22 lakes calculated using satellite altimetry. Assuming that MLS mimics the local undulations of the geoid, our study shows that over a large set of lakes (in East Africa, Andean mountain and Central Asia), short wavelength undulations of the geoid in poorly sampled areas can be derived using satellite altimetry. The models used in this study present very similar geographical patterns when compared to MLS. The precision of the models largely depends on the location of the lakes and is about 18 cm, in average over the Earth. MLS can serve as a validation dataset for any future geoid model. It will also be useful for validation of the future mission SWOT (Surface Water and Ocean Topography) which will measure and map water heights over the lakes with a high horizontal resolution of 250 by 250 m.  相似文献   
2.
3.
4.
DORIS is one of the four space-geodetic techniques participating in the Global Geodetic Observing System (GGOS), particularly to maintain and disseminate the Terrestrial Reference Frame as determined by International Earth rotation and Reference frame Service (IERS). A few years ago, under the umbrella of the International Association of Geodesy, a DORIS International Service (IDS) was created in order to foster international cooperation and to provide new scientific products. This paper addresses the organizational aspects of the IDS and presents some recent DORIS scientific results. It is for the first time that, in preparation of the ITRF2008, seven Analysis Centers (AC’s) contributed to derive long-term time series of DORIS stations positions. These solutions were then combined into a homogeneous time series IDS-2 for which a precision of less than 10 mm was obtained. Orbit comparisons between the various AC’s showed an excellent agreement in the radial component, both for the SPOT satellites (e.g. 0.5–2.1 cm RMS for SPOT-2) and Envisat (0.9–2.1 cm RMS), using different software packages, models, corrections and analysis strategies. There is now a wide international participation within IDS that should lead to future improvements in DORIS analysis strategies and DORIS-derived geodetic products.  相似文献   
5.
In preparation of ITRF2008, all geodetic technique services (VLBI, SLR, GPS and DORIS) are generating new solutions based on combination of individual analysis centers solutions. These data reprocessing are based on a selection of models, parameterization and estimation strategy unique to each analysis center and to each technique. While a good agreement can be found for models between groups, thanks to the existence of the IERS conventions, a great diversity still exist for parameter estimation, allowing possible future improvements in this direction. The goal of this study is to focus on the atmospheric drag estimation used to generate the new DORIS/IGN ignwd08 time series prepared for ITRF2008. We develop here a method to inter-compare different processing strategies. In a first step, by analyzing single-satellite solutions for a few weeks of data but for a large number of possible analysis strategies, we demonstrate that estimating drag coefficient more frequently (typically every 1–2 h instead of previously every 4–8 h) for the lowest DORIS satellites (SPOTs and Envisat) provides better geodetic results for station coordinates and polar motion. This new processing strategy also solved earlier problem found when processing DORIS data during intense geomagnetic events, such as geomagnetic storms. Differences between drag estimation strategies can mostly be found during these few specific periods of extreme geomagnetic activity (few days per year). In such a case, when drag coefficient is only estimated every 6 h or less often for single-satellite solution, a significant degradation in station coordinate accuracy can be observed (120 mm vs. 20 mm) and significant biases arose in polar motion estimation (5 mas vs. 0.3 mas). In a second step, we reprocessed a full year of DORIS data (2003) in a standard multi-satellite mode. We were able to provide statistics on a more reliable data set and to strengthen these conclusions. Our proposed DORIS analysis is easy to implement in all software packages and is now already used by several analysis centers of the International DORIS Service (IDS) when submitting reprocessed solutions for ITRF2008.  相似文献   
6.
For the first time, the International DORIS Service (IDS) has produced a technique level combination based on the contributions of seven analysis centers (ACs), including the European Space Operations Center (ESOC), Geodetic Observatory Pecny (GOP), Geoscience Australia (GAU), the NASA Goddard Space Flight Center (GSFC), the Institut Géographique National (IGN), the Institute of Astronomy, Russian Academy of Sciences (INASAN, named as INA), and CNES/CLS (named as LCA). The ACs used five different software packages to process the DORIS data from 1992 to 2008, including NAPEOS (ESA), Bernese (GOP), GEODYN (GAU, GSC), GIPSY/OASIS (INA), and GINS (LCA). The data from seven DORIS satellites, TOPEX/Poseidon, SPOT-2, SPOT-3, SPOT-4, SPOT-5, Envisat and Jason-1 were processed and all the analysis centers produced weekly SINEX files in either variance–covariance or normal equation format. The processing by the analysis centers used the latest GRACE-derived gravity models, forward modelling of atmospheric gravity, updates to the radiation pressure modelling to improve the DORIS geocenter solutions, denser parameterization of empirically determined drag coefficients to improve station and EOP solutions, especially near the solar maximum in 2001–2002, updated troposphere mapping functions, and an ITRF2005-derived station set for orbit determination, DPOD2005. The CATREF software was used to process the weekly AC solutions, and produce three iterations of an IDS global weekly combination. Between the development of the initial solution IDS-1, and the final solution, IDS-3, the ACs improved their analysis strategies and submitted updated solutions to eliminate troposphere-derived biases in the solution scale, to reduce drag-related degradations in station positioning, and to refine the estimation strategy to improve the combination geocenter solution. An analysis of the frequency content of the individual AC geocenter and scale solutions was used as the basis to define the scale and geocenter of the IDS-3 combination. The final IDS-3 combination has an internal position consistency (WRMS) that is 15 to 20 mm before 2002 and 8 to 10 mm after 2002, when 4 or 5 satellites contribute to the weekly solutions. The final IDS-3 combination includes solutions for 130 DORIS stations on 67 different sites of which 35 have occupations over 16 years (1993.0–2009.0). The EOPs from the IDS-3 combination were compared with the IERS 05 C04 time series and the RMS agreement was 0.24 mas and 0.35 mas for the X and Y components of polar motion. The comparison to ITRF2005 in station position shows an agreement of 6 to 8 mm RMS in horizontal and 10.3 mm in height. The RMS comparison to ITRF2005 in station velocity is at 1.8 mm/year on the East component, to 1.2 mm/year in North component and 1.6 mm/year in height.  相似文献   
7.
Doppler Orbitography Radiopositioning Integrated by Satellite (DORIS) and Global Positioning System (GPS) techniques are similarly affected by propagation delays in the neutral atmosphere (troposphere) and hence make use of similar data processing strategies for reducing this effect. We compare Zenith Tropospheric Delays (ZTDs) estimated from 52 DORIS and GPS station pairs co-located at 35 sites over the 2005–2008 period. We find an overall systematic negative mean bias of −4 mm and a median bias of −2 mm, with a large site-to-site scatter and especially stronger biases over South America, potentially linked to remaining problems related to the South Atlantic Anomaly (SAA) in the current DORIS data processing. The standard deviation of ZTD differences is in the range 4–12 mm over the globe (8 mm on average), with larger values located in the southern hemisphere. The spatial variability of differences is consistent with previous work but remains largely unexplained. DORIS is shown to be much less sensitive to instrumental changes than GPS (only the switch from Alcatel to Starec antenna at Toulouse is detected as an offset of −4 mm in the ZTD time series). On the opposite, discontinuities and spurious annual signals are found in the GPS ZTD solutions. A discontinuity of +5 mm is found on 5 November 2006, linked to the switch from relative to absolute GPS antenna models used in the data processing. The use of modified GPS antennas (e.g. at GODE) or improved antenna models is shown to reduce the spurious annual signal (e.g. from 5 mm to 2 mm at METS). Overall, the agreement between both techniques is good, though DORIS shows a significantly larger random scatter. The high stability and good spatial and temporal coverage make DORIS a potential candidate technique for meteorology and climate studies as long as reasonable time averaging can be applied (e.g. differences are reduced from 8.6 to 2.4 mm with 5-day averages) and no real-time application is considered. This technique could be considered as a potential contributor to Global Geodetic Observing System (GGOS) for climatology.  相似文献   
8.
For Precise Orbit Determination of altimetry missions, we have computed a data set of DORIS station coordinates defined for specific time intervals called DPOD2005. This terrestrial reference set is an extension of ITRF2005. However, it includes all new DORIS stations and is more reliable, as we disregard stations with large velocity formal errors as they could contaminate POD computations in the near future. About 1/4 of the station coordinates need to be defined as they do not appear in the original ITRF2005 realization. These results were verified with available DORIS and GPS results, as the integrity of DPOD2005 is almost as critical as its accuracy. Besides station coordinates and velocities, we also provide additional information such as periods for which DORIS data should be disregarded for specific DORIS stations, and epochs of coordinate and velocity discontinuities (related to either geophysical events, equipment problem or human intervention). The DPOD model was tested for orbit determination for TOPEX/Poseidon (T/P), Jason-1 and Jason-2. Test results show DPOD2005 offers improvement over the original ITRF2005, improvement that rapidly and significantly increases after 2005. Improvement is also significant for the early T/P cycles indicating improved station velocities in the DPOD2005 model and a more complete station set. Following 2005 the radial accuracy and centering of the ITRF2005-original orbits rapidly degrades due to station loss.  相似文献   
9.
An overview is given of the Productivity, Reliability, Availability, and Maintainability (PRAM) Project 00-256, which aims to integrate the Digital Multimedia Information System (DMIS) into the Reconnaissance Module Automatic Test System (RMATS). Benefits to be derived from the incorporation of the DMIS and return on investment for the US Air Force are discussed. The process used to obtain approval and funding support for this advanced maintenance aiding and data collection system is described  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号