首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   6篇
  免费   0篇
航空   4篇
综合类   1篇
航天   1篇
  2013年   1篇
  2010年   1篇
  2007年   2篇
  2003年   1篇
  1997年   1篇
排序方式: 共有6条查询结果,搜索用时 15 毫秒
1
1.
Goldsten  J. O.  McNutt  R. L.  Gold  R. E.  Gary  S. A.  Fiore  E.  Schneider  S. E.  Hayes  J. R.  Trombka  J. I.  Floyd  S. R.  Boynton  W. V.  Bailey  S.  Brückner  J.  Squyres  S. W.  Evans  L. G.  Clark  P. E.  Starr  R. 《Space Science Reviews》1997,82(1-2):169-216
An X-ray/gamma-ray spectrometer has been developed as part of a rendezvous mission with the near-Earth asteroid, 433 Eros, in an effort to answer fundamental questions about the nature and origin of asteroids and comets. During about 10 months of orbital operations commencing in early 1999, the X-ray/Gamma-ray Spectrometer will develop global maps of the elemental composition of the surface of Eros. The instrument remotely senses characteristic X-ray and gamma-ray emissions to determine composition. Solar excited X-ray fluorescence in the 1 to 10 keV range will be used to measure the surface abundances of Mg, Al, Si, Ca, Ti, and Fe with spatial resolutions down to 2 km. Gamma-ray emissions in the 0.1 to 10 MeV range will be used to measure cosmic-ray excited elements O, Si, Fe, H and naturally radioactive elements K, Th, U to surface depths on the order of 10 cm. The X-ray spectrometer consists of three gas-filled proportional counters with a collimated field of view of 5° and an energy resolution of 850 eV @ 5.9 keV. Two sunward looking X-ray detectors monitor the incident solar flux, one of which is the first flight of a new, miniature solid-state detector which achieves 600 eV resolution @ 5.9 keV. The gamma-ray spectrometer consists of a NaI(Tl) scintillator situated within a Bismuth Germanate (BGO) cup, which provides both active and passive shielding to confine the field of view and eliminate the need for a massive and costly boom. New coincidence techniques enable recovery of single and double escape events in the central detector. The NaI(Tl) and BGO detectors achieve energy resolutions of 8.7% and 14%, respectively @ 0.662 MeV. A data processing unit based on an RTX2010 microprocessor provides the spacecraft interface and produces 256-channel spectra for X-ray detectors and 1024-channel spectra for the raw, coincident, and anti-coincident gamma-ray modes. This paper presents a detailed overview of the X-ray/Gamma-ray Spectrometer and describes the science objectives, measurement objectives, instrument design, and shows some results from early in-flight data.  相似文献   
2.
We describe the instrument design and detector development for MANES which has been selected to fly on the Mars 2003 Lander. Section 1 explains the need for the spectrometer in determining the increased risk of carcinogenesis for astronauts. Section 2 presents the instrument design including an outline drawing, a cross-sectional view and a detailed block diagram. Sections 3 and 4 describe the low and high energy detector components of the spectrometer and present responses to monoenergetic neutron beams. Sections 5 and 6 explain the design approaches to charged particle discrimination and instrument transfer function modeling.  相似文献   
3.
重返巴厘岛     
老JO 《西南航空》2010,143(1):66-71
从吉隆坡一路飞来的国际航班终于在黄昏时分降落在了登巴萨(Denpasar)国际机场。在海关闸口前,从几个不同航班上下来的游客.迅速汇成了几条长龙。四年前那种门可罗雀的冷清场面恍如梦境,眼前这一切才是巴厘岛理所当然的热闹场景。在落日的余晖中走出机场.空气中依然弥散着一股特别的丁香烟气味——记忆中.只有巴厘岛才有的专属气息。  相似文献   
4.
An Engineering Radiation Monitor (ERM) has been developed as a supplementary spacecraft subsystem for NASA’s Radiation Belt Storm Probes (RBSP) mission. The ERM will monitor total dose and deep dielectric charging at each RBSP spacecraft in real time. Configured to take the place of spacecraft balance mass, the ERM contains an array of eight dosimeters and two buried conductive plates. The dosimeters are mounted under covers of varying shielding thickness to obtain a dose-depth curve and characterize the electron and proton contributions to total dose. A 3-min readout cadence coupled with an initial sensitivity of ~0.01 krad should enable dynamic measurements of dose rate throughout the 9-hr RBSP orbit. The dosimeters are Radiation-sensing Field Effect Transistors (RadFETs) and operate at zero bias to preserve their response even when powered off. The range of the RadFETs extends above 1000 krad to avoid saturation over the expected duration of the mission. Two large-area (~10 cm2) charge monitor plates set behind different thickness covers will measure the dynamic currents of weakly-penetrating electrons that can be potentially hazardous to sensitive electronic components within the spacecraft. The charge monitors can handle large events without saturating (~3000 fA/cm2) and provide sufficient sensitivity (~0.1 fA/cm2) to gauge quiescent conditions. High time-resolution (5 s) monitoring allows detection of rapid changes in flux and enables correlation of spacecraft anomalies with local space weather conditions. Although primarily intended as an engineering subsystem to monitor spacecraft radiation levels, real-time data from the ERM may also prove useful or interesting to a larger community.  相似文献   
5.
A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program mission to the planet Mercury. Mercury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) launched successfully in 2004 and will journey more than six years before entering Mercury orbit to begin a one-year investigation. The GRNS instrument forms part of the geochemistry investigation and will yield maps of the elemental composition of the planet surface. Major elements include H, O, Na, Mg, Si, Ca, Ti, Fe, K, and Th. The Gamma-Ray Spectrometer (GRS) portion detects gamma-ray emissions in the 0.1- to 10-MeV energy range and achieves an energy resolution of 3.5 keV full-width at half-maximum for 60Co (1332 keV). It is the first interplanetary use of a mechanically cooled Ge detector. Special construction techniques provide the necessary thermal isolation to maintain the sensor’s encapsulated detector at cryogenic temperatures (90 K) despite the intense thermal environment. Given the mission constraints, the GRS sensor is necessarily body-mounted to the spacecraft, but the outer housing is equipped with an anticoincidence shield to reduce the background from charged particles. The Neutron Spectrometer (NS) sensor consists of a sandwich of three scintillation detectors working in concert to measure the flux of ejected neutrons in three energy ranges from thermal to ∼7 MeV. The NS is particularly sensitive to H content and will help resolve the composition of Mercury’s polar deposits. This paper provides an overview of the Gamma-Ray and Neutron Spectrometer and describes its science and measurement objectives, the design and operation of the instrument, the ground calibration effort, and a look at some early in-flight data.  相似文献   
6.
NASA’s MESSENGER (MErcury Surface, Space ENvironment, GEochemistry, and Ranging) mission will further the understanding of the formation of the planets by examining the least studied of the terrestrial planets, Mercury. During the one-year orbital phase (beginning in 2011) and three earlier flybys (2008 and 2009), the X-Ray Spectrometer (XRS) onboard the MESSENGER spacecraft will measure the surface elemental composition. XRS will measure the characteristic X-ray emissions induced on the surface of Mercury by the incident solar flux. The Kα lines for the elements Mg, Al, Si, S, Ca, Ti, and Fe will be detected. The 12° field-of-view of the instrument will allow a spatial resolution that ranges from 42 km at periapsis to 3200 km at apoapsis due to the spacecraft’s highly elliptical orbit. XRS will provide elemental composition measurements covering the majority of Mercury’s surface, as well as potential high-spatial-resolution measurements of features of interest. This paper summarizes XRS’s science objectives, technical design, calibration, and mission observation strategy.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号