首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   12篇
  免费   0篇
航空   3篇
航天技术   6篇
航天   3篇
  2013年   1篇
  2011年   1篇
  2010年   5篇
  2008年   2篇
  2004年   1篇
  1986年   1篇
  1981年   1篇
排序方式: 共有12条查询结果,搜索用时 31 毫秒
1.
The High-Definition television (HDTV) system onboard the Japanese lunar explorer Kaguya (SELENE) consists of a telephotographic camera and a wide-angle camera that each have 2.2 M-pixel IT-CCDs (interline transfer charge-coupled devices) and LSIs (large-scale integrated circuits) of the several-million-gates class. One minute-long motion pictures acquired by the HDTV system at 30 fps (frames per second) are recorded in a 1 GB semiconductor memory after compression, and then transmitted to a ground station. In the development of the space-going HDTV system, a commercial ground-model HDTV system was extensively modified and evaluated for its suitability to withstand the harsh environment of space through environmental tests. The HDTV acquired a total of 6.3 TB of movies and still images of the Earth and the Moon over the mission period that started on September 29, 2007, and ended on June 11, 2009. Footage of an “Earth-rise” and an “Earth-set” on the lunar horizon were captured for the first time by the HDTV system. During a lunar eclipse, images of the Earth’s “diamond ring” were acquired for the first time. The CCDs and the instruments used in the system remained in good working order throughout the mission period, despite the harsh space environment, which suggests a potential new approach to the development of instruments for use in space.  相似文献   
2.
The absolute reflectance of the Moon has long been debated because it has been suggested (Hillier et al. in Icarus 151:205–225, 1999) that there is a large discrepancy between the absolute reflectance of the Moon derived from Earth-based telescopic data and that derived from remote-sensing data which are calibrated using laboratory-measured reflectance spectra of Apollo 16 bulk soil 62231. Here we derive the absolute reflectance of the lunar surface using spectral data newly acquired by SELENE (Kaguya) Multiband Imager and Spectral Profiler. The results indicate that the reflectance of the Apollo 16 standard site, which has been widely used as an optical standard in previous Earth-based telescopic and remote-sensing observations derived by Multiband Imager, is 47% at 415 nm and 67% to 76% at 750 to 1550 nm of the value for the Apollo 16 mature soil measured in an Earth-based laboratory. The data also suggest that roughly 60% of the difference is caused by the difference in soil composition and/or maturity between the 62231 sampling site and the Apollo 16 standard site and that the remaining 40% difference can be explained by the difference between the compaction states of the laboratory and the actual lunar surface. Consideration of the compaction states of the surface soil demonstrates its importance for understanding the spectral characteristics of the lunar surface. We also explain and evaluate data analysis procedures to derive reflectance from Multiband Imager data.  相似文献   
3.
Japan Aerospace Exploration Agency (JAXA) launched its own first manned experiment facility in space called the KIBO (Japanese Experiment Module, JEM) in 2008 and 2009 and started operations as part of International Space Station (ISS). To accomplish this Operation, JAXA made its own ground facility in Tsukuba, Japan, called Space Station Integration and Promotion Center (SSIPC). Ground personnel at SSIPC called the JEM Flight Control Team (JFCT) operate the KIBO and have learnt many lessons during its operation. In this presentation, some topics are chosen and explained such as (1) crew/ground personnel interaction and (2) planning lessons learned for manned space activities.  相似文献   
4.
An ultraviolet spectrometer, PHEBUS (Probing of Hermean Exosphere by Ultraviolet Spectroscopy) that is loaded onto the Mercury Planetary Orbiter in the BepiColombo mission is under development. The instrument, basically consisting of two spectrophotometers (EUV: 50–150 nm, FUV: 145–330 nm) and one scanning mirror, aims at measuring emission lines from molecules, atoms and ions present in the tenuous atmosphere of Mercury. The detectors employ microchannel plates as 2-D photon-counting devices. In order to enhance the quantum detection efficiencies, the surface of the top microchannel plates of EUV detector is covered with photocathode. This method enables us to identify weak atmospheric signatures such as neon (73.5 nm) and argon (104.8 nm), which could not be detected with conventional detector systems. This paper presents measurements of the performance characteristics of potassium bromide and esium iodide photocathodes, which have been evaluated for use in the EUV channel.  相似文献   
5.
The Multiband Imager (MI) is a high-resolution, multi-spectral imaging instrument for lunar exploration. It consists of two cameras, VIS and NIR, and is carried on the SELenological and ENgineering Explorer (SELENE), launched on Sep. 14, 2007. During the observation from January 2008 to June 2009, MI acquired about 450,000 scenes of multispectral image. The radiometric properties of the cameras were characterized using the pre-flight data derived in laboratory experiments with a calibrated integrating sphere. Twelve light source sets were used to examine the S/N ratio, linearity, and saturation level of the cameras. The dark field signal is quite stable in both cameras, having a noise level of less than 1 DN (VIS) and 2 DN (NIR). The fluctuation in the light field is also low (<2 DN), indicating that the spatial nonuniformity in the camera responses can be removed using a flat field. In order to remove the smear signals due to the frame transfer in the VIS data, we developed an iterate algorithm using all bands in the VIS camera. The S/N ratio, which is critical to the precision of the product, is estimated to exceed 160 for the VIS bands and 400 for the NIR bands under low illumination conditions (5% of lunar surface reflectance). Based on the S/N ratio, the radiometric error due to the noise is calculated to be less than 0.7% for VIS and 0.2% for NIR. The relationship between input and output of the VIS camera is linear with a residual of less than 0.6 DN, corresponding to a radiometric error of 0.3%. The NIR exhibits a non-linear response to the input radiance. A cubic function best fits the pre-flight data with an average residual of 8 DN (corresponds to an error of 0.8%). Validation using in-flight data indicated that the instability of the dark output has not changed, but the level of dark output has slightly changed in the NIR bands (less than 6 DN). The pixel-to-pixel sensitivity variation in the orbit has been changed from that in the pre-flight experiment. The difference between the in-flight data and the pre-flight data ranges within ±2%. There is also a small (less than ±1%) but nonnegligible difference between in-flight data of different cycles in both the VIS and NIR bands, suggesting that the coefficient for spatial ununiformity correction needs to be calculated for each cycle.  相似文献   
6.
The Mercury’s Sodium Atmosphere Spectral Imager (MSASI) on BepiColombo will address fundamental scientific questions pertaining to the Mercury’s sodium exosphere. Together, our measurements on the overall scale will provide ample new information on regolith–exosphere–magnetosphere coupling as well as new understanding of the dynamics governing the surface-bounded exosphere. We will compare the four different source mechanisms in preparation for modeling MSASI data and show the feasibility of identifying a process.  相似文献   
7.
Extreme and far ultraviolet imaging spectrometers are proposed for the low-altitude orbiter of the BepiColombo mission. The UV instrument, consisting of the two spectrometers with common electronics, aims at measuring (1) emission lines from molecules, atoms and ions present in the Mercury’s tenuous atmosphere and (2) the reflectance spectrum of Mercury’s surface. The instrument pursues a complete coverage in UV spectroscopy. The extreme UV spectrometer covers the spectral range of 30–150 nm with the field of view of 5.0°, and the spectrum from 130 to 430 nm is obtained by the far UV spectrometer. The extreme UV spectrometer employs multi-layer coating technology to enhance its sensitivity at particular emission lines. This technology enables us to identify small ionospheric signatures such as He II (30.4 nm) and Na II (37.2 nm), which could not be detected with conventional optics.  相似文献   
8.
We have installed the first MAGDAS magnetometer at Fayum in Egypt. The ambient temperature in the initial sensor house varied more than ±4 °C in one day (24 h period). This variation made the magnetic data useless. To correct this problem, (1) a new sensor house was re-constructed which reduced the diurnal variation to less than ±1 °C, and (2) the “Uozumi Temperature Correction Method” was introduced. As a result, good data is now arriving in real time at a central facility in Japan.  相似文献   
9.
For the future Japanese exploration mission of the Jupiter’s magnetosphere (JMO: Jupiter Magnetospheric Orbiter), a unique instrument named JUXTA (Jupiter X-ray Telescope Array) is being developed. It aims at the first in-situ measurement of X-ray emission associated with Jupiter and its neighborhood. Recent observations with Earth-orbiting satellites have revealed various X-ray emission from the Jupiter system. X-ray sources include Jupiter’s aurorae, disk emission, inner radiation belts, the Galilean satellites and the Io plasma torus. X-ray imaging spectroscopy can be a new probe to reveal rotationally driven activities, particle acceleration and Jupiter–satellite binary system. JUXTA is composed of an ultra-light weight X-ray telescope based on micromachining technology and a radiation-hard semiconductor pixel detector. It covers 0.3–2 keV with the energy resolution of <100 eV at 0.6 keV. Because of proximity to Jupiter (∼30 Jovian radii at periapsis), the image resolution of <5 arcmin and the on-axis effective area of >3 cm2 at 0.6 keV allow extremely high photon statistics and high resolution observations.  相似文献   
10.
An Earth-orbiting small satellite “EXtreme ultraviolet spectrosCope for ExosphEric Dynamics” (EXCEED) which will be launched in 2012 is under development. The mission will carry out spectroscopic and imaging observation of EUV (Extreme Ultraviolet: 60–145 nm) emissions from tenuous plasmas around the planets (Venus, Mars, Mercury, and Jupiter). It is essential for EUV observation to put on an observing site outside the Earth’s atmosphere to avoid the absorption. It is also essential that the detection efficiency must be very high in order to catch the faint signals from those targets. In this mission, we employ cesium iodide coated microchannel plate as a 2 dimensional photon counting devise which shows 1.5–50 times higher quantum detection efficiency comparing with the bared one. We coat the surface of the grating and entrance mirror with silicon carbides by the chemical vapor deposition method in order to archive the high diffraction efficiency and reflectivity. The whole spectrometer is shielded by the 2 mm thick stainless steel to prevent the contamination caused by the high energy electrons from the inner radiation belt. In this paper, we will introduce the mission overview, its instrument, and their performance.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号