首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   8篇
  免费   0篇
航空   1篇
航天技术   5篇
航天   2篇
  2019年   2篇
  2014年   1篇
  2011年   1篇
  2010年   2篇
  2008年   1篇
  2007年   1篇
排序方式: 共有8条查询结果,搜索用时 15 毫秒
1
1.
2.
On 21 June 2010 the TerraSAR-X satellite was joined by the TanDEM-X satellite. A Global Positioning System (GPS) radio occultation (RO) experiment using the twin satellites has been carried out to estimate the precision of GPS atmospheric soundings. For the Day Of Year (DOY) 330–336, 2011, we analyze phase and amplitude data recorded by GPS receivers separated by a few hundred meters in a low earth orbit and derive collocated atmospheric refractivity profiles. In the altitude range 10–20 km the standard deviation between TerraSAR-X and TanDEM-X refractivity does not exceed 0.15%. The standard deviation is rapidly increasing for lower and higher altitudes; close to the surface and at an altitude of 30 km the standard deviation reaches 0.8% and 0.5%, respectively. Systematic deviations between TerraSAR-X and TanDEM-X refractivity in the considered altitude range (0–30 km) are negligible. The results confirm the anticipated high precision of the GPS RO technique. However, the difference in the retrieved refractivity in the lower troposphere for different Open Loop (OL) signal tracking parameters, altered onboard TanDEM-X for DOY 49–55, 2012, calls for an in depth analysis. At the moment we can not exclude that a potential bias in the OL Doppler model introduces a bias in our retrieved refractivity at altitudes <8<8 km.  相似文献   
3.
The MOPITT (Measurements of Pollution in the Troposphere) instrument has provided more than nine years of global carbon monoxide (CO) measurements on a continuous basis since its launch aboard the Terra Spacecraft on December 18th, 1999. This paper gives an overview of the core sub-system performance and major issues of the in-flight instrument over the mission period. Some of the instrument anomalies are also discussed. The major successes are: (1) the concept of using a combination of correlation systems such as Length Modulated Cells (LMCs) and Pressure Modulated Cells (PMCs) to retrieve CO profiles in the troposphere; (2) the redundant design in the instrumentation which was crucial for coping with unexpected in-flight anomalies and for continuing the mission in the case of component failure; (3) the thermal environment on orbit that is so stable that some calibration procedures are not necessary; and (4) the recent production of CO total column retrieved from the MOPITT 2.3 μm channel.  相似文献   
4.
The German Research Centre for Geosciences (GFZ) operates a GNSS water vapour tomography system using about 350 German GNSS stations. The GNSS data processing at the GFZ works in near real-time and provides zenith total delays, integrated water vapour and slant delay data operationally. This large data set of more than 50,000 slant delays per hour is used to reconstruct spatially resolved humidity fields by means of tomographic techniques. It can be expected that additional observations from the future Galileo system provide more information with improved quality. A simulation study covering 12 h at 14 July 2009 was therefore started to estimate the impact of GPS, Galileo and GLONASS data on the GNSS tomography. It is shown that the spatial coverage of the atmosphere with slant paths is highly improved by combining observations from two or three satellite systems. Equally important for a reliable tomographic reconstruction is the distribution of slant path intersections as they are required to locate the integrated delay information. The number of intersection points can be increased by a factor of 4 or 8 if two or three systems are combined and their distribution will cover larger regions of the atmosphere. The combined data sets can be used to increase the spatiotemporal resolution of the reconstructed humidity fields up to 30 km horizontally, 300 m vertically and 15 min. The reconstruction quality could not be improved considerably using the currently available techniques.  相似文献   
5.
The precise modeling and knowledge of non-gravitational forces acting on satellites is of big interest to many scientific tasks and missions. Since 2002, the twin GRACE satellites have measured these forces in a low Earth orbit with highly precise accelerometers, for about 15?years. Besides the significance for the GRACE mission, these measurement data allow the evaluation of modeling approaches and the improvement of force models. Unfortunately, before any scientific usage, the accelerometer measurements need to be calibrated, namely scale factor and bias have to be regularly estimated.In this study we demonstrate an accelerometer calibration approach, solely based on high precision non-gravitational force modeling without any use of empirically or stochastically estimated parameters, using our in-house developed satellite simulation tool XHPS. The aim of this work is twofold, first we use the accelerometer data and the residuals resulting from the calibration to quantitatively analyze and validate different non-gravitational force model approaches. In a second step, we compare the calibration results to three different calibration methods from different authors, based on gravity field recovery, GPS-based precise orbit determination, and based on modeled accelerations.We consider atmospheric drag forces and winds, as well as radiation forces due to solar radiation pressure, albedo, Earth infrared and thermal radiation (TRP) of the satellite itself. For TRP, we investigate different transient temperature calculation approaches for the satellite surfaces with absorbed power from the aforementioned radiation sources. A detailed finite element model of the satellite is utilized for every force, considering orientation, material properties and shadowing conditions for each element.For cross-track and radial direction, which are mainly affected by the radiative forces, our calibration residuals are quite small when drag is not super dominant (1–3?nm/s2 for total accelerations around ±50?nm/s2). For these directions the calibration seems to perform better than the other compared methods, where some bigger differences were found. For the drag dominated along-track direction it is vice versa, here our method is not sensitive enough because the difference between modeled and measured drag is bigger (e.g. residuals around 10?nm/s2 for total accelerations around ±70?nm/s2 for low solar activity). In along-track direction the orbit determination based methods are more sensitive and produce more reliable results. Results for the complete GRACE mission time span from 2003 to 2017 are shown, covering different seasonal environmental conditions.  相似文献   
6.
Formate, a simple organic acid known to support chemotrophic hyperthermophiles, is found in hot springs of varying temperature and pH. However, it is not yet known how metabolic strategies that use formate could contribute to primary productivity in hydrothermal ecosystems. In an effort to provide a quantitative framework for assessing the role of formate metabolism, concentration data for dissolved formate and many other solutes in samples from Yellowstone hot springs were used, together with data for coexisting gas compositions, to evaluate the overall Gibbs energy for many reactions involving formate oxidation or reduction. The result is the first rigorous thermodynamic assessment of reactions involving formate oxidation to bicarbonate and reduction to methane coupled with various forms of iron, nitrogen, sulfur, hydrogen, and oxygen for hydrothermal ecosystems. We conclude that there are a limited number of reactions that can yield energy through formate reduction, in contrast to numerous formate oxidation reactions that can yield abundant energy for chemosynthetic microorganisms. Because the energy yields are so high, these results challenge the notion that hydrogen is the primary energy source of chemosynthetic microbes in hydrothermal ecosystems.  相似文献   
7.
People often communicate with reference to informally agreed places, such as “the city centre”. However, views of the spatial extent of such areas may vary, resulting in imprecise regions. We compare perceptions of Sheffield’s City Centre from a street survey to extents derived from various web-based sources. Such automated approaches have advantages of speed, cost and repeatability. We show that footprints from web sources are often in concordance with models derived from more labour-intensive methods. Notable exceptions however were found with sources advertising or selling residential property. Agreement between sources was measured by aggregating them to identify locations of consensus.  相似文献   
8.
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号