首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到10条相似文献,搜索用时 78 毫秒
1.
常用的元件破损在线监测方法受外在因素影响较大,以γ能谱中关键裂变产物核素比活度进行在线定量分析是一种可靠的元件破损监测方法。针对新型LaBr3(Ce)元件破损监测仪,设计了元件破损模拟实验,对逸出的裂变产物采用HPGe和LaBr3(Ce)探测器进行了对比测量。通过不同冷却时间γ能谱的核素分析,确定了135Xe,88Kr,138Xe,88Rb,138Cs等可作为LaBr3(Ce)元件破损γ能谱监测的关键核素。同时,制备了覆盖能量范围(250~2 400)keV,含60Co,137Cs,133Ba;241Am,152Eu;109Cd,88Y,57Co及24Na的4组放射性标准溶液,在建立的效率校准系统上,校准了LaBr3(Ce)在线监测仪的效率。在反应堆一次异常情况分析中,已校准的LaBr3(Ce)元件破损监测仪对关键核素的现场分析结果与HPGe的取样分析结果一致,表明效率校准结果准确,校准方法可靠。  相似文献   

2.
用于校准航空γ谱仪的137Cs,60Co大面积航空平面源对传统的涂刷制源技术提出了挑战,为确保平面上的均匀性,借鉴现代网格点阵喷涂技术,将137Cs,60Co两种放射性标准溶液分别定量滴注在底衬滤纸上,晾干后热塑封并用环氧树脂将塑封片固定在梯形铝板上,由8块梯形铝板拼接为边长1m的正六边形航空平面源。制备的航空平面源的扩展不确定度(k=2)为4%,不均匀性优于10%。  相似文献   

3.
In residues of several iron meteorites, obtained by dissolution of the metal in dilute H2SO4, the isotopic ratio of 190Os/184Os has been measured by radiochemical neutron activation analysis and is found to be anomalous in several cases. The largest deviation so far seen is a 40% enrichment of 184Os in a mineral of Sikhote Alin. A lack of homogenization of the two isotopes that are produced in different nucleosynthetic processes suggests that iron meteorites are more primitive than any other matter available to us so far. Isotopic composition of Xe is found to be planetary in general. However the two light isotopes 124Xe and 126Xe are strongly depleted in some non-magnetic residues. Correlation diagrams of isotopic ratio pairs indicate that a two component mixture model is not adequate. EPR studies of the non-magnetic fractions of the residues show a large concentration of stabilized free radicals which could be ascribed to an irradiation of micro-inclusions prior to compaction into the metal matrix.  相似文献   

4.
The oncogenic potential of high-energy 56Fe particles (1 GeV/nucleon) accelerated with the Alternating Gradient Synchrotron at the Brookhaven National Laboratory was examined utilizing the mouse C3H 10T1/2 cell model. The dose-averaged LET for high-energy 56Fe is estimated to be 143 keV/μm with the exposure conditions used in this study. For 56Fe ions, the maximum relative biological effectiveness (RBEmax) values for cell survival and oncogenic transformation were 7.71 and 16.5 respectively. Compared to 150 keV/μm 4He nuclei, high-energy 56Fe nuclei were significantly less effective in cell killing and oncogenic induction. The prostaglandin E1 analog misoprostol, an effective oncoprotector of C3H 10T1/2 cells exposed to X rays, was evaluated for its potential as a radioprotector of oncogenic transformation with high-energy 56Fe. Exposure of cells to misoprostol did not alter 56Fe cytotoxicity or the rate of 56Fe-induced oncogenic transformation.  相似文献   

5.
We present six ROSAT PSPC observations of Seyfert 1 galaxies chosen to have low Galactic line-of-sight absorption (NH 1020 cm−2). As expected, it is found that all of these sources possess significantly steeper spectra below 1 keV, than that observed at higher X-ray energies. In addition we find evidence for soft X-ray spectral features, which are best parameterized as line emission at 0.63 keV in NGC7469 and 0.75 keV in ESO198-G24. We examine these results in the light of the accuracy of the PSPC spectral calibration.  相似文献   

6.
The data from the synchronous-orbit satellites of the Gorizont series are used to study the dependences of the ion flux variation amplitudes in the synchronous altitude region (the diurnal behaviour) on particle energies and on the form and rigidity of the particle energy spectrum. The proton fluxes were measured in the energy range E 60–120 keV, and the [N,0]2+ and [C,N,0]4+ ion fluxes in the energy range E 60–70 keV/e.

The ratio of the diurnal variation amplitudes of the studied ions is shown to correspond to the similarity of their energy spectra in the E/Q representation. The magnetically-quiet time gradient of the distribution function F(μ,J,L) in the synchronous-orbit region is shown to be (∂F/∂L)=0 for the H+ and [N,0]2+ ions and (∂F/∂L) > 0 for the [C,N,0]4+ ions (at the values of μ corresponding to the examined energy ranges). During magnetically-disturbed periods the inner boundary of the (∂F/∂L)=0 region shifts to lower L and (∂ F/∂L) = O in the synchronous altitude region must be also for the [C,N,O]4+ ions.  相似文献   


7.
We report on the luminosity dependent change of the cyclotron resonance energy obtained from a transient X-ray pulsar, 4U 0115+63. Using RXTE data observed on 1999 March, we found that the fundamental resonance energy stayed constant (11 keV) when the source luminosity was above 5 × 1037 erg s−1. As the luminosity decreased below 5 × 1037 erg s−1, the fundamental resonance energy gradually increased up to 16 keV at 0.16 × 1037 erg s−1. The luminosity dependence of the resonance energy can be understood by the change of the accretion column height.  相似文献   

8.
We present results from ROSAT observations of NGC 1808 and NGC 2903. Exposures of 10 ksec each with the PSPC detector show X-ray sources at the central positions of both galaxies which are classified as nuclear starburst galaxies. Both targets, NGC 1808 and NGC 2903 appear slightly extended in X-ray maps in the energy band 0.1–2.4 keV. The X-ray spectrum of NGC 1808 shows almost complete absorption below 0.5 keV, indicating an extremely high hydrogen column density towards that source (NH ≈ 8 × 1021cm−2 resulting from model fits on the PSPC spectrum). In case of NGC 2903, the number of counts in the ROSAT band is significantly lower than expected from a previous EINSTEIN investigation of the source.  相似文献   

9.
Ring current ions and relativistic electrons simultaneously measured on board MOLNIYA-1 are analyzed in comparison with the ground-based magnetometer data for the period of a strong magnetic storm (|Dst|max≈230 nT). Injection of >500 keV electrons into the slot region (L≈3) near equatorial plane is occurred on time scale ≈1 hour, when, during the magnetic storm maximum, the extreme low-latitude position of auroral electrojets is reached and ring current becomes more symmetrical. Positions of both the ring current maximum and electron intensity maximum (Lmax) are consistent to our previous result: |Dst|max = 2.75 • 104/L4max. An extreme storm-time low-latitude position of the west electrojet center (for amplitudes of |Dst|max up to 600 nT) is shown to be in a good consistence with this empirical dependence. It is supposed the trapped radiation boundary collapses down to L≈Lmax in the course of the storm main phase.  相似文献   

10.
We have studied the induction of morphological transformation of Syrian hamster embryo cells by low doses of heavy ions with different linear energy transfer (LET), ranging from 13 to 400 keV/μm. Exponentially growing cells were irradiated with 12C or 28Si ion beams generated by the Heavy Ion Medical Accelerator in Chiba (HIMAC), inoculated to culture dishes, and transformed colonies were identified when the cells were densely stacked and showed a crisscross pattern. Over the LET range examined, the frequency of transformation induced by the heavy ions increased sharply at very low doses no greater than 5 cGy. The relative biological effectiveness (RBE) of the heavy ions relative to 250 kVp X-rays showed an initial increase with LET, reaching a maximum value of about 7 at 100 keV/μm, and then decreased with the further increase in LET. Thus, we confirmed that high LET heavy ions are significantly more effective than X-rays for the induction of in vitro cell transformation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号