高温应变计在瞬态加热条件下温度特性的试验研究
引用本文:尹福炎.高温应变计在瞬态加热条件下温度特性的试验研究[J].强度与环境,2005,32(2):8-18.
作者姓名:尹福炎
作者单位:北京强度环境研究所,北京,100076
摘    要:在瞬态加热条件下,应变计的瞬时热输出特性与应变计在慢速升温条件的热输出曲线有明显的差别。这种差别随着温升速率的提高将更加明显,本文主要介绍这种差别的试验研究结果。

关 键 词:瞬态加热  高温应变计  应变测量误差
文章编号:1006-3919(2005)02-0008-11
修稿时间:2004年2月9日

Testing for temperature characteristics of high-temperature strain gauge under transient heating condition
YIN Fu-yan.Testing for temperature characteristics of high-temperature strain gauge under transient heating condition[J].Structure & Environment Engineering,2005,32(2):8-18.
Authors:YIN Fu-yan
Abstract:There are obvious difference between both the transient thermal output characteristic of high temperature strain gauges in transient heating condition and the thermal output curve of one in slow heating condition. This difference raises with heating rate. In this article we will describe principally the test results for the difference of thermal output.
Keywords:transient heating  high temperature strain gauge  strain measuring error