Space Radiation Damage Measurements in the Earth Synchronous Orbit
Authors:Sarles  FW Stanley  AG Roberge  JK Godfrey  BW
Institution:M.I.T. Lincoln Laboratory Lexington, Mass. 02173;
Abstract:For direct measurement of the integrated radiation dose experienced in Earth synchronous orbit, p-i-n diodes were flown as radiation dosimeters on LES-6. The diode, which has a lifetime of 10-4 seconds in the intrinsic region, was originally developed as a neutron dosimeter, but can detect 1-MeV electron fluences as low as 1013 e·cm-2. Observations over three years in orbit are presented.