摘    要:从流量现场校准装置的结构和测量方法入手,对校准装置的测量误差进行了分析,并根据分析结果对校准装置的测量结果进行了误差修正。通过试验对修正结果进行了验证。验证结果表明,通过测量误差的修正,校准装置的流量测量相对误差可以满足系统设计指标的要求。

关 键 词:流量现场校准装置  误差分析  误差修正

Analysis and Correction of Measurement Error of Field Calibration Device of Flowrate
HOU Yi,ZHU Yan,CHAI Yanli.Analysis and Correction of Measurement Error of Field Calibration Device of Flowrate[J].Aviation Metrology & Measurement Technology,2010,30(3):41-43,48.
Authors:HOU Yi  ZHU Yan  CHAI Yanli
Institution:(Changcheng Institute of Metrology & Measurement,Beijing 100095,China)
Abstract:Starting with the configuration and measurement method of flowrate field calibration device,this paper analyzes the measurement error of calibration,and makes error correction to the measurement results of calibration device based on the result of error analysis.The result of error correction is verified by experiments.Through error correction of measurement,the result of verification indicats that the relative error of flow rate field calibration device satisfis the target demand of system design.
Keywords:field calibration device of flowrate  measurement error analysis  error correction