Relative biological effectiveness and microdosimetry of a mixed energy field of protons up to 200 MeV.
Authors:J B Robertson  J M Eaddy  J O Archambeau  G B Coutrakon  D W Miller  M F Moyers  J V Siebers  J M Slater  J F Dicello
Affiliation:East Carolina University, Greenville, NC 27858, USA.
Abstract:We have studied radiation effects utilizing the new 250 MeV Synchrotron at Loma Linda University Medical Center. In this paper we present the data collected for the survival of Chinese hamster lung (V79) cells, that were irradiated with a beam of mixed energy protons up to 200 MeV. The RBE for protons, when compared to 60Co gamma rays, ranged from a low of 1.2 at the high energy portion of the field to 1.3+ at the low energy portion of the field. These results are consistent with the measured lineal energy (microdosimetric) spectra.