首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Relative biological effectiveness and microdosimetry of a mixed energy field of protons up to 200 MeV.
Authors:J B Robertson  J M Eaddy  J O Archambeau  G B Coutrakon  D W Miller  M F Moyers  J V Siebers  J M Slater  J F Dicello
Institution:East Carolina University, Greenville, NC 27858, USA.
Abstract:We have studied radiation effects utilizing the new 250 MeV Synchrotron at Loma Linda University Medical Center. In this paper we present the data collected for the survival of Chinese hamster lung (V79) cells, that were irradiated with a beam of mixed energy protons up to 200 MeV. The RBE for protons, when compared to 60Co gamma rays, ranged from a low of 1.2 at the high energy portion of the field to 1.3+ at the low energy portion of the field. These results are consistent with the measured lineal energy (microdosimetric) spectra.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号