Dosimetric measurements in manned missions
Authors:Reitz G  Beaujean R  Leicher M
Institution:

* DLR, Aerospace Medicine, Radiation Biology Section, Under Höhe, D-51147, Köln, Germany

Institut für Kernphysik der Universität Kiel, Olshausenstr. 40/60, D-24118, Kiel, Germany

Abstract:Detector packages consisting of thermoluminescence detectors (TLDs), nuclear emulsions and plastic nuclear track detectors were exposed in different sections of the MIR space station, inside the Spacelab during the IML1 mission, and inside Spacelab module and tunnel during the D2 mission. This report concentrates on total dose measurements with TLDs during these mission. The results are discussed and compared to results of former missions and to calculations. Finally, dose equivalents and mean quality factors for each mission are presented which are derived from the TLD results and results obtained from the other detector systems. Dose equivalents range between 200 μSvd−1 and 700 μSvd−1.
Keywords:space dosimetry  Quality factor  dose equivalent