首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Fringe fitting and group delay determination for geodetic VLBI observations of DOR tones
Authors:Songtao Han  Axel Nothnagel  Zhongkai Zhang  Rüdiger Haas  Qiang Zhang
Institution:1. National Key Laboratory of Science and Technology on Aerospace Flight Dynamics, Beijing Aerospace Control Center, Beiqinglu 26, 100094 Beijing, China;2. Institute of Geodesy and Geoinformation, University of Bonn, Nußallee 17, 53115 Bonn, Germany;3. Chalmers University of Technology, Onsala Space Observatory, SE-439 92 Onsala, Sweden
Abstract:Extracting the group and phase delays of interferometric observations produced in the Very Long Baseline Interferometry (VLBI) measurement concept requires a special fringe fitting and delay search algorithm for the recorded bandwidth. While fringe fitting is in use routinely for several megahertz wide channels in geodetic and astrometric VLBI with quasar observations, fringe fitting for artificial tones of very small bandwidth of artificial signals for Differential One-way Ranging (DOR) requires a different way of handling. In a project called Observing the Chang’E-3 Lander with VLBI (OCEL), the DOR tones emitted by the Chang’E-3 lander were observed in a standard geodetic VLBI mode with 8 or 4?MHz wide channels to maintain compatibility with the corresponding quasar observations. For these observations, we modified the existing fringe fitting program of the Haystack Observatory Processing Software (HOPS), fourfit, to properly handle narrow band DOR tones. The main motivations are that through this modification, the data of quasars and artificial radio sources can be processed in the existing geodetic analysis pipeline, and that the algorithm can be used for similar projects as well. In this paper, we describe the algorithm and show that the new algorithm produces much more reliable group delay results than using the standard fourfit algorithm. This is done by a simulation test and in particular by processing of real observations. It is shown that in many cases, systematic deviations of several nanoseconds, which are seen with the standard fourfit algorithm, can be avoided. The ultimate benefit of the new procedure is demonstrated by reducing the errors in delay triangle closures by at least a factor of 3, which, in the OCEL case, is from ~300 to ~100?ps.
Keywords:Fringe fitting  DOR tones  Geodetic VLBI  Chang’E-3 lander
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号