首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Comparison of organ dose and dose equivalent for human phantoms of CAM vs. MAX
Authors:Myung-Hee Y Kim  Garry D Qualls  Tony C Slaba  Francis A Cucinotta
Institution:1. Universities Space Research Association, 2101 NASA Parkway, Houston, TX 77058, USA;2. NASA Langley Research Center, Hampton, VA 23681-2199, USA;3. Old Dominion University, E&CS Building, Elkhorn Ave., Norfolk, VA 23529, USA;4. NASA Johnson Space Center, 2101 NASA Parkway, Houston, TX 77058, USA
Abstract:For the evaluation of organ dose and dose equivalent of astronauts on space shuttle and the International Space Station (ISS) missions, the CAMERA models of CAM (Computerized Anatomical Male) and CAF (Computerized Anatomical Female) of human tissue shielding have been implemented and used in radiation transport model calculations at NASA. One of new human geometry models to meet the “reference person” of International Commission on Radiological Protection (ICRP) is based on detailed Voxel (volumetric and pixel) phantom models denoted for male and female as MAX (Male Adult voXel) and FAX (Female Adult voXel), respectively. We compared the CAM model predictions of organ doses to those of MAX model, since the MAX model represents the male adult body with much higher fidelity than the CAM model currently used at NASA. Directional body-shielding mass was evaluated for over 1500 target points of MAX for specified organs considered to be sensitive to the induction of stochastic effects. Radiation exposures to solar particle event (SPE), trapped protons, and galactic cosmic ray (GCR) were assessed at the specific sites in the MAX phantom by coupling space radiation transport models with the relevant body-shielding mass. The development of multiple-point body-shielding distributions at each organ made it possible to estimate the mean and variance of organ doses at the specific organ. For the estimate of doses to the blood forming organs (BFOs), data on active marrow distributions in adult were used to weight the bone marrow sites over the human body. The discrete number of target points of MAX organs resulted in a reduced organ dose and dose equivalent compared to the results of CAM organs especially for SPE, and should be further investigated. Differences of effective doses between the two approaches were found to be small (<5%) for GCR.
Keywords:Organ dose and dose equivalent  Human tissue models  Risk assessment  Solar particle events  Galactic cosmic ray  Radiation protection
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号