首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于旋量理论及距离误差的机械臂标定新方法
引用本文:谭月胜,孙汉旭,贾庆轩,邵志宇.基于旋量理论及距离误差的机械臂标定新方法[J].北京航空航天大学学报,2006,32(9):1104-1108.
作者姓名:谭月胜  孙汉旭  贾庆轩  邵志宇
作者单位:1.北京航空航天大学 机械工程及自动化学院, 北京 100083
基金项目:国家高技术研究发展计划(863计划)
摘    要:为提高机械臂的定位及定姿精度,必须对其进行标定.标定能否达到预期目的,主要取决于所采用的运动学模型及消除参数识别过程中外来误差的影响.分析了基于不同运动学模型时机械臂的初始位姿误差对标定结果的影响.提出了一种结合旋量理论与距离模型的标定用数学模型.该模型考虑了机械臂初始位姿误差对标定的影响,解决了用D-H参数建模存在的弊端,同时能消除因机械臂坐标系统与测量设备坐标系统之间转换所带来的误差,克服了测量技术上的困难.仿真计算验证了这种新标定数学模型的可行性. 

关 键 词:机械臂    运动学标定    螺旋理论    距离误差    数学模型    误差分析
文章编号:1001-5965(2006)09-1104-05
收稿时间:2005-11-23
修稿时间:2005年11月23日

New manipulator calibration method based on screw theory and distance error
Tan Yuesheng,Sun Hanxu,Jia Qingxuan,Shao Zhiyu.New manipulator calibration method based on screw theory and distance error[J].Journal of Beijing University of Aeronautics and Astronautics,2006,32(9):1104-1108.
Authors:Tan Yuesheng  Sun Hanxu  Jia Qingxuan  Shao Zhiyu
Institution:1.School of Mechanical Engineering and Automation, Beijing University of Aeronautics and Astronautics, Beijing 100083, China2. Automation School, Beijing University of Post and Telecommunication Beijing 100876, China
Abstract:Accuracy of a manipulator is determined by its ability to position and orient its end-effector at the desired point in its workspace. It must be calibrated in order to improve its position accuracy. Kinematic model and the disturbance of exterior error are critical to the manipulator calibration. The effect of the manipulators′ initial orientation error on calibration was analyzed withdifferent kinematic model. A new mathematical model for manipulator calibration, which makes use of screw theory and distance error model, rather than conventional Denavit-Hartenberg(D-H) parameters and position error, was proposed. Based on the new model, the initial orientation errors of the manipulator were included thereinto. The nature drawbacks of D-H parameters in which small errors in theactual structure do not result in small changes in the kinematic parameters were avoided. The error resulting from the transformation between a measurement device frame system and a manipulator frame system was eliminated, and the difficulty in measurement technology could be overcome. Simulation was made to verify the correctness of the model.
Keywords:manipulator  kinematic calibration  screw theory  distance error  mathematical models  error analysis
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《北京航空航天大学学报》浏览原始摘要信息
点击此处可从《北京航空航天大学学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号