首页 | 本学科首页   官方微博 | 高级检索  
     

用热流探针测量激波速度
引用本文:张仕忠,李贤,李进平,陈宏,俞鸿儒. 用热流探针测量激波速度[J]. 气动实验与测量控制, 2014, 0(5): 86-91
作者姓名:张仕忠  李贤  李进平  陈宏  俞鸿儒
作者单位:中国科学院力学研究所高温气体动力学国家重点实验室,北京100190
摘    要:激波速度测量是激波管和激波风洞运行状态的一个重要参数,压电传感器或光学方法测速系统成本高,而传统电离探针在激波马赫数较低、波后温度达不到空气电离程度的情况下无法满足实验要求。提出了一种使用同轴热电偶作为测速探针来测激波速度的方法,弥补了电离探针在激波马赫数较低时的不足。介绍了同轴热电偶探针测速原理,并设计了测量激波速度的系统电路。通过信号放大电路锁定激波冲激信号,触发脉冲信号发生电路,实现了一种单通道、多测点的激波风洞测速系统。分别开展以温度与热流为触发信号的风洞实验,结果表明只有使用热流信号才能满足激波测速的时间要求。

关 键 词:热流探针  激波速度  同轴热电偶  电离探针  激波风洞

The measurement of shock wave velocity by heat flux probe
Zhang Shizhong,Li Xian,Li Jinping,Chen Hong,Yu Hongru. The measurement of shock wave velocity by heat flux probe[J]. , 2014, 0(5): 86-91
Authors:Zhang Shizhong  Li Xian  Li Jinping  Chen Hong  Yu Hongru
Affiliation:(State Key Laboratory of High Temperature Gas Dynamics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China)
Abstract:Shock wave velocity is one of the most important parameters in shock tube for determining the running states.It can be measured through shock pressure or optical method,of which the cost will be high in large systems.Ionization-probe is an effective means of determining the velocity of detonation or strong shock waves by using the conductivity behind the shock wave, but it may not meet the experimental requirements under the condition that the shock wave velocity is so low that the air behind the shock wave cannot reach the ionization temperature.A thermocouple flux probe with high frequency response is used in our measurement system to over-come the aforementioned disadvantages.Based on traditional ionization-probe circuit,the ther-mocouple probe measurement circuit is redesigned.The shock wave signal is amplified and locked to trigger the pulse generating circuit to obtain the shock velocity signal.The key of the circuit design is that the secondary amp signal interference is particularly large after the thermal simula-tion network,due to the load through a capacitor,therefore,the magnification of the secondary amplification circuit cannot be too high,but the amplitude of heat flux signal is determined by the magnification,so the relationship between the two factors need to be balanced.Temperature and heat flux signals are used as trigger signals respectively.The delay times contrasted with piezoelectric sensors are inconsistent when the trigger signal is temperature.The first pulse delays 130 microseconds,and the second delays 80 microseconds,which is because the limit trigger voltages have error.When the trigger source is heat flux signal,the circuit can be triggered without delay to obtain more accurate shock wave velocity.The resutls show that only heat flux signal can meet the time requirements of shock velocity.This method overcomes the drawbacks of traditional ionization probe,and can be widely applied to various shock tubes for shock wave velocity meas-urement.
Keywords:heat flux probe  shock wave velocity  thermocouple probe  ionization-probe  shock tube
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号