Absorbed dose measurements on external surface of Kosmos-satellites with glass thermoluminescent detectors.
Authors:Arkhangelsky" target="_blank">V V Akatov YuAArkhangelsky  E E Kovalev  F Spurny  I Votochkova
Institution:Institute of Medico-Biological Problems, Ministry of Health of the U.S.S.R., Moscow.
Abstract:In this paper we present absorbed dose measurements with glass thermoluminescent detectors on external surface of satellites of Kosmos-serie flying in 1983-87. Experiments were performed with thermoluminescent aluminophosphate glasses of thicknesses 0.1, 0.3, 0.4, 0.5, and 1 mm. They were exposed in sets of total thickness between 5 and 20 mm, which were protected against sunlight with thin aluminized foils. In all missions, extremely high absorbed dose values were observed in the first layers of detectors, up to the thickness of 0.2 to 0.5 gcm-2. These experimental results confirm that, during flights at 250 to 400 km, doses on the surface of the satellites are very high, due to the low energy component of the proton and electron radiation.