Monitoring of biologically effective UV irradiance at El Arenosillo (INTA), Andalucia, in Spain.
Authors:R de la Torre  G Horneck  P Rettberg  E Luccini  J M Vilaplana  M Gil
Institution:INTA, Div Space Sciences, Spanish Aerospace Research Establishment, Madrid, Spain.
Abstract:Biological UV (ultraviolet) dosimetry was applied using the biofilm-technique (DLR patent) to determine the UV levels weighted of biologically weighted UV radiation at the INTA Sounding Station of El Arenosillo at Huelva, Spain (37 degrees 06'N, 6 degrees 44'W, 50 m a s 1=above sea level) on 2 days in 1997 correction of 1977] (April 1, and May 5). Exposure periods were calculated for clear sky days using a radiative transfer model for erythemal doses to reach 1.3 to 1.5 MED (minimal erythemal dose). Reliability of the radiative transfer model was demonstrated by the doses registered by a Yankee-UV biometer for the same exposure periods as used for the biosensor. This work presents the methodology employed (biofilm-technique utilized correction of utiliced], calculation of exposing periods with radiative transfer model, etc) and the results obtained with the Yankee biometer and the biofilm. At noon, the ratio of biofilm measurements (Ieff, W/m2=biological effective irradiance, in W/m2) to the UV Biometer data (in MED/h) was 3-4.