首页 | 本学科首页   官方微博 | 高级检索  
     

运输类飞机动力装置溅水试验技术
引用本文:赵海刚,屈霁云,马争胜,符小刚,戚学锋. 运输类飞机动力装置溅水试验技术[J]. 航空动力学报, 2021, 36(12): 2673-2682. DOI: 10.13224/j.cnki.jasp.20200542
作者姓名:赵海刚  屈霁云  马争胜  符小刚  戚学锋
作者单位:中国航空工业集团有限公司中国飞行试验研究院,西安710089;中国商用飞机有限责任公司上海飞机设计研究院,上海201210
摘    要:基于对中国民用航空局(CAAC)运输类飞机适航标准和美国联邦航空管理局(FAA)咨询通告的分析、解读,分别从工程试验与适航验证两个方面,研究了溅水试验程序、试验水池方案设计与滑行速度测量与控制技术,制定了符合适航标准体系的运输类飞机动力装置溅水试验审定程序,以ARJ21-700型支线飞机合格审定试飞为平台,完整进行了相...

关 键 词:适航标准  运输类飞机  动力装置  溅水试验  滑行速度
收稿时间:2020-12-19

Water ingestion test technical of transport aircraft power system
ZHAO Haigang,QU Jiyun,MA Zhengsheng,FU Xiaogang,QI Xuefeng. Water ingestion test technical of transport aircraft power system[J]. Journal of Aerospace Power, 2021, 36(12): 2673-2682. DOI: 10.13224/j.cnki.jasp.20200542
Authors:ZHAO Haigang  QU Jiyun  MA Zhengsheng  FU Xiaogang  QI Xuefeng
Affiliation:1.Chinese Flight Test Establishment,Aviation Industry Corporation of China Limited,Xi'an 710089,China2.Shanghai Aircraft Design and Research Institute,Commercial Aircraft Corporation of China Limited,Shanghai 201210,China
Abstract:On the basis of analyzing and interpreting the Chinese civil regulations transport airworthiness standards of Civil Aviation Administration of China (CAAC) and advisory circular of Federal Aviation Administration (FAA),the water ingestion test program,test pool scheme and landing speed measurement and control technology was studied and designed from two aspects of engineering test and airworthiness verification.Based on the airworthiness standard system,the procedure of transport aircraft power system water ingestion test was developed and applied in the ARJ21-700 aircraft flight test.The results showed that the designed water ingestion test procedure was reasonable and feasible,and it was able to verify power systemcompliance with standards completely when the transport aircraft passed through the water contaminated runway;the critical speed of ARJ21-700 aircraft equipped with CF34-10A engine was 166.6 km/h in aircraft taking off and slipping through the water contaminate runway;the maximum fluctuations of the rotation rate of fan and compressor,and inter turbo temperature were 5.1%,1.7% and 39 ℃.The performance of engine was better in idle state compared with maximum reverse thrust state in the aircraft landing and slipping through the water contaminated runway.So it could meet the airworthiness standard.The procedure and technology provide a direct support for the power system water ingestion test of C919,C929 and other transport aircrafts. 
Keywords:airworthiness standard  transport aircraft  power system  water ingestion test  aircraft slipping speed
本文献已被 万方数据 等数据库收录!
点击此处可从《航空动力学报》浏览原始摘要信息
点击此处可从《航空动力学报》下载全文