首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   5篇
  免费   0篇
航空   2篇
航天技术   3篇
  2002年   1篇
  1998年   1篇
  1992年   1篇
  1985年   2篇
排序方式: 共有5条查询结果,搜索用时 15 毫秒
1
1.
Thermospheric temperature, composition and wind measurements from the Dynamics Explorer satellite (DE-2) are interpreted using a three dimensional, multiconstituent spectral model. The analysis accounts for tides driven by the absorbed solar radiation as well as energy and momentum coupling involving the magnetosphere and lower atmosphere. We discuss phenomena associated with the annual tide, polar circulation, magnetic storms and substorms.  相似文献   
2.
This paper reports the results of the first direct comparison of near simultaneous measurements obtained by the INTERCOSMOS-BULGARIA-1300 and the DYNAMICS EXPLORER-B satellites. The ICB-1300 is in a near circular orbit at a mean height of about 850 km. The DE-B satellite in an elliptical orbit is sometimes directly below the ICB-1300 satellite providing an opportunity to investigate the response of the thermosphere to particle fluxes from the magnetosphere. Energy fluxes in the range 0.2–15 keV are obtained from an energetic particle analyzer on board the ICB-1300 satellite. The thermospheric composition and density are obtained by a neutral gas mass spectrometer (NACS) on the DE-B satellite. During the period 20 August–20 November, 1981, observations show tht the times and locations of maxima in magnetospheric energy deposition coincide with regions of maximum thermospheric upwelling characterized by composition changes.  相似文献   
3.
Galileo Probe Mass Spectrometer experiment   总被引:1,自引:0,他引:1  
The Galileo Probe Mass Spectrometer (GPMS) is a Probe instrument designed to measure the chemical and isotopic composition including vertical variations of the constituents in the atmosphere of Jupiter. The measurement will be performed by in situ sampling of the ambient atmosphere in the pressure range from approximately 150 mbar to 20 bar. In addition batch sampling will be performed for noble gas composition measurement and isotopic ratio determination and for sensitivity enhancement of non-reactive trace gases.The instrument consists of a gas sampling system which is connected to a quadrupole mass analyzer for molecular weight analysis. In addition two sample enrichment cells and one noble gas analysis cell are part of the sampling system. The mass range of the quadrupole analyzer is from 2 amu to 150 amu. The maximum dynamic range is 108. The detector threshold ranges from 10 ppmv for H2O to 1 ppbv for Kr and Xe. It is dependent on instrument background and ambient gas composition because of spectral interference. The threshold values are lowered through sample enrichment by a factor of 100 to 500 for stable hydrocarbons and by a factor of 10 for noble gases. The gas sampling system and the mass analyzer are sealed and evacuated until the measurement sequence is initiated after the Probe enters into the atmosphere of Jupiter. The instrument weighs 13.2 kg and the average power consumption is 13 W.The instrument follows a sampling sequence of 8192 steps and a sampling rate of two steps per second. The measurement period lasts appropriately 60 min through the nominal pressure and altitude range.  相似文献   
4.
Niemann  H.B.  Atreya  S.K.  Bauer  S.J.  Biemann  K.  Block  B.  Carignan  G.R.  Donahue  T.M.  Frost  R.L.  Gautier  D.  Haberman  J.A.  Harpold  D.  Hunten  D.M.  Israel  G.  Lunine  J.I.  Mauersberger  K.  Owen  T.C.  Raulin  F.  Richards  J.E.  Way  S.H. 《Space Science Reviews》2002,104(1-4):553-591
The Gas Chromatograph Mass Spectrometer (GCMS) on the Huygens Probe will measure the chemical composition of Titan's atmosphere from 170 km altitude (∼1 hPa) to the surface (∼1500 hPa) and determine the isotope ratios of the major gaseous constituents. The GCMS will also analyze gas samples from the Aerosol Collector Pyrolyser (ACP) and may be able to investigate the composition (including isotope ratios) of several candidate surface materials. The GCMS is a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns. The mass spectrometer employs five ion sources sequentially feeding the mass analyzer. Three ion sources serve as detectors for the GC columns and two are dedicated to direct atmosphere sampling and ACP gas sampling respectively. The instrument is also equipped with a chemical scrubber cell for noble gas analysis and a sample enrichment cell for selective measurement of high boiling point carbon containing constituents. The mass range is 2 to 141 Dalton and the nominal detection threshold is at a mixing ratio of 10− 8. The data rate available from the Probe system is 885 bit/s. The weight of the instrument is 17.3 kg and the energy required for warm up and 150 minutes of operation is 110 Watt-hours. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   
5.
The Galileo Probe entered the atmosphere of Jupiter on December 7, 1995. Measurements of the chemical and isotopic composition of the Jovian atmosphere were obtained by the mass spectrometer during the descent over the 0.5 to 21 bar pressure region over a time period of approximately 1 hour. The sampling was either of atmospheric gases directly introduced into the ion source of the mass spectrometer through capillary leaks or of gas, which had been chemically processed to enhance the sensitivity of the measurement to trace species or noble gases. The analysis of this data set continues to be refined based on supporting laboratory studies on an engineering unit. The mixing ratios of the major constituents of the atmosphere hydrogen and helium have been determined as well as mixing ratios or upper limits for several less abundant species including: methane, water, ammonia, ethane, ethylene, propane, hydrogen sulfide, neon, argon, krypton, and xenon. Analysis also suggests the presence of trace levels of other 3 and 4 carbon hydrocarbons, or carbon and nitrogen containing species, phosphine, hydrogen chloride, and of benzene. The data set also allows upper limits to be set for many species of interest which were not detected. Isotope ratios were measured for 3He/4He, D/H, 13C/12C, 20Ne/22Ne, 38Ar/36Ar and for isotopes of both Kr and Xe.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号