首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   2篇
  免费   0篇
航空   1篇
航天技术   1篇
  2010年   1篇
  1998年   1篇
排序方式: 共有2条查询结果,搜索用时 0 毫秒
1
1.
The High-Definition television (HDTV) system onboard the Japanese lunar explorer Kaguya (SELENE) consists of a telephotographic camera and a wide-angle camera that each have 2.2 M-pixel IT-CCDs (interline transfer charge-coupled devices) and LSIs (large-scale integrated circuits) of the several-million-gates class. One minute-long motion pictures acquired by the HDTV system at 30 fps (frames per second) are recorded in a 1 GB semiconductor memory after compression, and then transmitted to a ground station. In the development of the space-going HDTV system, a commercial ground-model HDTV system was extensively modified and evaluated for its suitability to withstand the harsh environment of space through environmental tests. The HDTV acquired a total of 6.3 TB of movies and still images of the Earth and the Moon over the mission period that started on September 29, 2007, and ended on June 11, 2009. Footage of an “Earth-rise” and an “Earth-set” on the lunar horizon were captured for the first time by the HDTV system. During a lunar eclipse, images of the Earth’s “diamond ring” were acquired for the first time. The CCDs and the instruments used in the system remained in good working order throughout the mission period, despite the harsh space environment, which suggests a potential new approach to the development of instruments for use in space.  相似文献   
2.
Frequencies of asymmetrical type of chromosome aberration were scored in cultured human blood lymphocytes irradiated with carbon and neon beams. Blood cells were irradiated with various doses to establish dose response curves for chromosome aberration frequency vs. dose, and chromosome preparation was made by conventional method. Dose response curves for the per cell frequencies of the dicentrics and centric rings as well as the excess amount of acentric fragments were described for 7 different qualities (LET= 22.4, 40.0, 41.5, 69.9, 70.0, 100.0 and 150 KeV/μm) of carbon and neon beams with three different energies, 135, 290 and 400 MeV/u. From the analysis of those dose response curves, the maximum effect was found in the region of LET value at near 70 KeV/μm together with linear expression in the response from all endpoints examined. The 135 MeV/u of carbons (69.9 KeV/μm) and neons (70.0 KeV/μm) showed linear response. The 290 MeV/u of carbons (100 KeV/m) and neons (150 KeV/μm) showed medium effects with different shape of response, linear with a plateau and upward concavity. The 2 carbon beams (41.5 and 40 KeV/μm) from 2 different accelerators showed much discrepancy in the response. RBE-LET relationship was also described by comparing the coefficient of the 7 different dose responses. The peak (near 70 KeV/m) was localized colse to that (80 KeV/m) for the survivals of dsb repair deficient cells (Eguchi-Kasai et al. 1998), but in different position from that previously reported in many other studies (100–200 KeV/mm). Identification of the RBEmax in the present study has yet to be definitive.  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号