Ambiguities in interferometers with high angular accuracy must be resolved to achieve a practical system design. A new technique for ambiguity resolution is described and is based on monopulse circuitry used with the interferometric elements. The overall angular accuracy of the system is achieved by the interferometer; the angular accuracy of the monopulse subsystem is used to resolve interferometric ambiguities. An expression for the probability of correct ambiguity resolution is derived as a function of element size and monopulse accuracy which indicates that high probability of ambiguity resolution results when the size of the interferometric elements are a fraction of the interferometric baseline. Finally, a comparison between conventional monopulse and interferometric system designs is made for the three principal parameters, signal sensitivity, angular accuracy, and field of view, that dictate the appropriate choice for a particular application. Interferometric systems are more appropriate than monopulse systems for those applications in which angular accuracy and field of view are more important than signal sensitivity.  相似文献   