首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   19篇
  免费   0篇
航空   1篇
航天技术   13篇
航天   5篇
  2018年   1篇
  2014年   1篇
  2013年   1篇
  2012年   1篇
  2011年   1篇
  2010年   1篇
  2004年   1篇
  2003年   1篇
  1998年   1篇
  1996年   1篇
  1995年   2篇
  1994年   1篇
  1992年   1篇
  1989年   2篇
  1985年   2篇
  1982年   1篇
排序方式: 共有19条查询结果,搜索用时 31 毫秒
1.
For estimating radiation risk in space flights it is necessary to determine radiation dose obtained by critical organs of a human body. For this purpose the experiments with human body models are carried out onboard spacecraft. These models represent phantoms equipped with passive and active radiation detectors which measure dose distributions at places of location of critical organs. The dosimetric Liulin-5 telescope is manufactured with using three silicon detectors for studying radiation conditions in the spherical tissue-equivalent phantom on the Russian segment of the International space station (ISS). The purpose of the experiment with Liulin-5 instrument is to study dynamics of the dose rate and particle flux in the phantom, as well as variations of radiation conditions on the ISS over long time intervals depending on a phase of the solar activity cycle, orbital parameters, and presence of solar energetic particles. The Liulin-5 dosimeter measures simultaneously the dose rate and fluxes of charged particles at three depths in the radial channel of the phantom, as well as the linear energy transfer. The paper presents the results of measurements of dose rate and particle fluxes caused by various radiation field components on the ISS during the period from June 2007 till December 2009.  相似文献   
2.
Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year.  相似文献   
3.
A dosimetry-radiometry system has been developed at the Space Research Institute of the Bulgarian Academy of Science to measure the fluxes and dose rates on the flight of the second Bulgarian cosmonaut. The dosimetry system is designed for monitoring the different space radiations, such as solar cosmic rays, galactic cosmic rays and trapped particles in the earth radiation belts. The system consists of a battery operated small size detector unit and a "read-write" and telemetry microcomputer unit. The sensitivity of the instrument (3.67 x 10(-8) rad/pulse) permits high resolution measurements of the flux and dose rate along the track of the Mir space station. We report our initial results for the period of the flight between the 7th and 17th June 1988.  相似文献   
4.
Based on Polar satellite data, the authors have studied the auroral disturbances that arose during the passage by the Earth of compressed plasma regions formed in front of high-speed solar wind streams (the CIR region) and in front of magnetic clouds (the Sheath region). The aurorae observed by the Polar satellite possessed basic signatures of a substorm: a localized onset and expansion toward the pole and westward and eastward. However, in these cases they had a very large size in longitude and latitude and occupied a very large area. All disturbances observed by the Polar satellite during the Sheath and CIR regions of the solar wind in December of 1996, in 1997–1998, and in 2000 were analyzed. Eight events during disturbance development in the ionosphere, when the Geotail satellite was located in the plasma sheet of the magnetospheric tail, were selected. It is shown that in all selected cases some typical signatures of substorm development in the magnetospheric tail were observed, namely: (1) fast plasma flows (flow reversal, i.e., from tailwards to Earthwards) and (2) a sharp decrease of the total pressure, which followed an interval of total pressure increase. One can draw the conclusion that in the CIR and Sheath regions with a high solar wind density, substorm disturbances of a specific type are observed, with large latitudinal and longitudinal size (sometimes occupying the entire polar cap).  相似文献   
5.
Since 1988 high sensitivity semiconductor dosimeter-radiometer “Liulin” worked on board of MIR space station. Device measured the absorbed dose rate and the flux of penetrating particles. The analysis of the data hows the following new results:

In October 1989 and after March 24, 1991, two additional stable maximums in flux channel were observed in the southern-eastern part of South Atlantic Anomaly (SAA). These two maximums existed at least several months and seem to be due to trapped high energy electron and proton fluxes. In April 1991 additional maximums were localized in the following geographical coordinates regions: LATITUDE = (−35 °)–(−50 °) LONGITUDE = 332 ° − 16 ° and lat.(−46 °)–(−52 °) long. 360 ° − 60 °. Additional maximums diffusion occurs inside radiation belt. Appearance of these maximums seems to be closely connected with preceding powerful solar proton events and associated geomagnetic dynamics of new belt disturbances. After the series of solar proton events in June 1991 we observed significant enhancement of this new radiation belt formation. To achieve sufficient accuracy of dose rate predictions in low Earth orbits the structure and dynamics of new belt should be carefully analyzed to be included in a new environment model.

From the inter comparison of the data from “Liulin” and French developed tissue equivalent LET spectrometer NAUSICAA in the time period August–November 1992 we come to the following conclusions: Mainly there is good agreement between both data sets for absorbed dose in the region of SAA; Different situation of the instruments on the station can explain the cases when differences up to 2 times are observed; At high latitudes usually the tissue equivalent absorbed dose observations are 2 times larger than “Liulin” doses.  相似文献   

6.
Using data from dosimetry-radiometry system "Liulin" on board of "Mir"-space station the particle flux and doserate during September-October, 1989 has been studied. The orbit of the station was 379 km perigee, 410 km apogee and 51.6 degrees inclination. Special attention has been paid to the flux and doserate changes inside the station after intensive solar proton events (SPE) on 29 of September, 1989. The comparison between the doses before and after the solar flares shows increase of the calculated mean dose per day by factor of 10 to 200. During the SPE on the 29 of September the additional dose was 310 mrad. The results of the experiment are compared with the data for the solar proton fluxes obtained on the GOES-7 satellite.  相似文献   
7.
The dosimetric experiments Dose-M and Liulin as part of the more complex French-German-Bulgarian-Russian experiments for the investigation of the radiation environment for Mars-96 mission are described. The experiments will be realized with dosemeter-radiometer instruments, measuring absorbed dose in semiconductor detectors and the particle flux. Two detectors will be mounted on board the Mars-96 orbiter. Another detector will be on the guiderope of the Mars-96 Aerostate station. The scientific aims of Dose-M and Liulin experiments are: Analysis of the absorbed dose and the flux on the path and around Mars behind different shielding. Study of the shielding characteristics of the Martian atmosphere from galactic and solar cosmic rays including solar proton events. Together with the French gamma-spectrometer and the German neutron detectors the investigation of the radiation environment on the surface of Mars and in the atmosphere up to 4000 m altitude will be conducted.  相似文献   
8.
The Liulin-5 experiment is a part of the international project MATROSHKA-R on the Russian segment of the ISS, which uses a tissue-equivalent spherical phantom equipped with a set of radiation detectors. The objective of the MATROSHKA-R project is to provide depth dose distribution of the radiation field inside the sphere in order to get more information on the distribution of dose in a human body. Liulin-5 is a charged particle telescope using three silicon detectors. It measures time resolved energy deposition spectra, linear energy transfer (LET) spectra, particle flux, and absorbed doses of electrons, protons and heavy ions, simultaneously at three depths along the radius of the phantom. Measurements during the minimum of the solar activity in cycle 23 show that the average absorbed daily doses at 40 mm depth in the phantom are between 180 μGy/day and 220 μGy/day. The absorbed doses at 165 mm depth in the phantom decrease by a factor of 1.6–1.8 compared to the doses at 40 mm depth due to the self-shielding of the phantom from trapped protons. The average dose equivalent at 40 mm depth is 590 ± 32 μSV/day and the galactic cosmic rays (GCR) contribute at least 70% of the total dose equivalent at that depth. Shown is that due to the South Atlantic Anomaly (SAA) trapped protons asymmetry and the direction of Liulin-5 lowest shielding zone the dose rates on ascending and descending nodes in SAA are different. The data obtained are compared to data from other radiation detectors on ISS.  相似文献   
9.
Based on data from satellite INTERCOSMOS-BULGARIA-1300, the latitudinal distribution of oxygen and helium ions in the topside ionosphere is discussed for night-time equinox at high solar activity. A comparison with the corresponding IRI-79 distribution is made. The vertical IRI ion composition profile is checked with measurements made with VERTICAL-10 rocket. Some recommendations are made in order to improve the IRI-modelling of the ion composition in the topside ionosphere.  相似文献   
10.
An experiment involving active detection of space radiation was carried out in the Space Research Institute (SRI) of Bulgarian Academy of Sciences, in preparation of the flight of the second Bulgarian cosmonaut. The radiations that would be encountered on the flight were modelled including solar and galactic cosmic rays and the particle radiation in the Earth's radiation belts. The dose rate was calculated for these different radiations behind the shielding of the space station. The variations in dose rates over the period of the flight were calculated and compared with measurements made during the orbit of the Mir Space Station. The calculated and measured dose rates agreed within 15-35%.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号