首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   35篇
  免费   0篇
  国内免费   1篇
航空   33篇
航天技术   1篇
航天   2篇
  2016年   2篇
  2015年   1篇
  2014年   1篇
  2012年   1篇
  2009年   3篇
  2008年   1篇
  2003年   1篇
  2000年   1篇
  1999年   1篇
  1994年   1篇
  1990年   1篇
  1989年   3篇
  1986年   1篇
  1985年   5篇
  1983年   4篇
  1982年   1篇
  1981年   1篇
  1980年   4篇
  1975年   1篇
  1974年   1篇
  1966年   1篇
排序方式: 共有36条查询结果,搜索用时 15 毫秒
21.
A design algorithm is considered for transformers that must transfer electric power across a rotating interface. Among other features, this procedure allows the designer to minimize either weight or losses for either a fixed magnetizing inductance or a fixed leakage inductance. Numerical results are included to indicate the design tradeoffs between various parameters.  相似文献   
22.
To assess the effects of prolonged space flight on the electrophysiological properties of the heart, vectorcardiograms (VCG) were obtained on the Skylab crews at regular intervals during flight and the pre- and postflight periods. The VCG signals were telemetered from Skylab and analyzed by digital computer. Conventional 12-lead electrocardiograms were derived from the VCG signals by a lead transformation program. Standardized exercise loads were incorporated into the experiment protocol to increase the sensitivity of the VCG for effects of deconditioning and to detect susceptibility for arrhythmias. In Skylab II, 24 preflight, 21 inflight, and 19 postflight experiments were analyzed. Statistically significant inflight changes observed in two or more crew members included: decreased resting heart rate, increased QRS duration, anterior shift QRS vector, increased QRS vector magnitude, anterior shift T vector, and increased T vector magnitude. One astronaut had occasional premature ventricular contractions (PVC) during the pre- and postflight phases. He had a single episode of multiple PVC's during heavy-load exercise testing in flight. A second astronaut had no arrhythmia during pre- or inflight testing. On postflight day 21 he had multiple PVC's and salvos of ectopic ventricular beats. He has had no recurrence of the arrhythmia. With the exception of the cardiac arrhythmias, no deleterious electrophysiological changes were observed during Skylab II.  相似文献   
23.
The Cepheid-like pulsations of some of the R CrB stars should in principle make it possible to determine their masses and hence to place constraints on possible evolution scenarios. We briefly review the evidence for these pulsations and discuss the problem of how these low-mass, hydrogen-deficient carbon stars could have evolved to their present position in the H-R diagram. Linear and nonlinear pulsation calculations are reviewed. It is found that for these large luminosity to mass ratio (L/M) stars a region of pulsation instability extends considerably hotter than for normal high luminosity Cepheids. The envelopes of these models are so nonadiabatic that the identification of modes becomes very difficult since there is frequently no clearly defined nodal structure. For the most extreme L/M cases it is found that the models are unstable in the sense that they appear on the verge of ejecting the outer layers.  相似文献   
24.
A steady state model is derived for the full-bridge series-resonant power converter. Normalized parametric curves for various currents and voltages are then plotted versus the triggering angle of the switching devices. The calculations are compared with experimental measurements made on a 50 kHz converter and a discussion of certain operating problems is presented.  相似文献   
25.
26.
27.
We present a 6.3 hour observation of 4U1624-49 with the EXOSAT Medium Energy experiment. The X-ray light curve is dominated by a series of sharp dips in which the observed flux falls to 25% of the steady level on timescales of seconds. These dips are accompanied by strong variations in the spectral hardness consistent with large changes in the absorbing column density. No evidence is found for any dip periodicity, in contrast to the other four sources in which dip activity has been reported. We discuss the implications of these observations for models of low mass X-ray binaries.  相似文献   
28.
The IBEX-Hi Neutral Atom Imager of the Interstellar Boundary Explorer (IBEX) mission is designed to measure energetic neutral atoms (ENAs) originating from the interaction region between the heliosphere and the local interstellar medium (LISM). These ENAs are plasma ions that have been heated in the interaction region and neutralized by charge exchange with the cold neutral atoms of the LISM that freely flow through the interaction region. IBEX-Hi is a single pixel ENA imager that covers the ENA spectral range from 0.38 to 6 keV and shares significant energy overlap and overall design philosophy with the IBEX-Lo sensor. Because of the anticipated low flux of these ENAs at 1 AU, the sensor has a large geometric factor and incorporates numerous techniques to minimize noise and backgrounds. The IBEX-Hi sensor has a field-of-view (FOV) of 6.5°×6.5° FWHM, and a 6.5°×360° swath of the sky is imaged over each spacecraft spin. IBEX-Hi utilizes an ultrathin carbon foil to ionize ENAs in order to measure their energy by subsequent electrostatic analysis. A multiple coincidence detection scheme using channel electron multiplier (CEM) detectors enables reliable detection of ENAs in the presence of substantial noise. During normal operation, the sensor steps through six energy steps every 12 spacecraft spins. Over a single IBEX orbit of about 8 days, a single 6.5°×360° swath of the sky is viewed, and re-pointing of the spin axis toward the Sun near perigee of each IBEX orbit moves the ecliptic longitude by about 8° every orbit such that a full sky map is acquired every six months. These global maps, covering the spectral range of IBEX-Hi and coupled to the IBEX-Lo maps at lower and overlapping energies, will answer fundamental questions about the structure and dynamics of the interaction region between the heliosphere and the LISM.  相似文献   
29.
The IBEX-Lo sensor covers the low-energy heliospheric neutral atom spectrum from 0.01 to 2 keV. It shares significant energy overlap and an overall design philosophy with the IBEX-Hi sensor. Both sensors are large geometric factor, single pixel cameras that maximize the relatively weak heliospheric neutral signal while effectively eliminating ion, electron, and UV background sources. The IBEX-Lo sensor is divided into four major subsystems. The entrance subsystem includes an annular collimator that collimates neutrals to approximately 7°×7° in three 90° sectors and approximately 3.5°×3.5° in the fourth 90° sector (called the high angular resolution sector). A fraction of the interstellar neutrals and heliospheric neutrals that pass through the collimator are converted to negative ions in the ENA to ion conversion subsystem. The neutrals are converted on a high yield, inert, diamond-like carbon conversion surface. Negative ions from the conversion surface are accelerated into an electrostatic analyzer (ESA), which sets the energy passband for the sensor. Finally, negative ions exit the ESA, are post-accelerated to 16 kV, and then are analyzed in a time-of-flight (TOF) mass spectrometer. This triple-coincidence, TOF subsystem effectively rejects random background while maintaining high detection efficiency for negative ions. Mass analysis distinguishes heliospheric hydrogen from interstellar helium and oxygen. In normal sensor operations, eight energy steps are sampled on a 2-spin per energy step cadence so that the full energy range is covered in 16 spacecraft spins. Each year in the spring and fall, the sensor is operated in a special interstellar oxygen and helium mode during part of the spacecraft spin. In the spring, this mode includes electrostatic shutoff of the low resolution (7°×7°) quadrants of the collimator so that the interstellar neutrals are detected with 3.5°×3.5° angular resolution. These high angular resolution data are combined with star positions determined from a dedicated star sensor to measure the relative flow difference between filtered and unfiltered interstellar oxygen. At the end of 6 months of operation, full sky maps of heliospheric neutral hydrogen from 0.01 to 2 keV in 8 energy steps are accumulated. These data, similar sky maps from IBEX-Hi, and the first observations of interstellar neutral oxygen will answer the four key science questions of the IBEX mission.  相似文献   
30.
The overload characteristics of the full bridge series resonant power converter are considered. This includes analyses of the two most common control methods presently in use. The first of these uses a current zero crossing detector to synchronize the control signals and is referred to as the ? controller. The second is driven by a voltage controlled oscillator and is referred to as the ? controller. It is shown that the ? controller has certain reliability advantages in that it can be designed with inherent short circuit protection. Experimental results are included for an 86 kHz converter using power metal-oxide-semiconductor field-effect transistors (MOSFETs).  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号