首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new version of the HZETRN code capable of simulating HZE ions with either laboratory or space boundary conditions is under development. The computational model consists of combinations of physical perturbation expansions based on the scales of atomic interaction, multiple scattering, and nuclear reactive processes with use of asymptotic/Neumann expansions with non-perturbative corrections. The code contains energy loss with straggling, nuclear attenuation, nuclear fragmentation with energy dispersion and downshifts, and off-axis dispersion with multiple scattering under preparation. The present benchmark is for a broad directed beam for 1 A GeV iron ion beams with 2 A MeV width and four targets of polyethylene, polymethyl metachrylate, aluminum, and lead of varying thickness from 5 to 30 g/cm2. The benchmark quantities will be dose, track averaged LET, dose averaged LET, fraction of iron ion remaining, and fragment energy spectra after 23 g/cm2 of polymethyl metachrylate.  相似文献   

2.
Cyclotron-accelerated heavy ion beams provide a fine degree of control over the physical parameters of radiation. Cytogenetics affords a view into the irradiated cell at the resolution of chromosomes. Combined they form a powerful means to probe the mechanisms of RBE. Cytogenetic studies with high energy heavy ion beams reveal three LET-dependent trends for 1) level of initial damage, 2) distribution of damage among cells, and 3) lesion severity. The number of initial breaks per unit dose increases from a low-LET plateau to a peak at approximately 180 keV/micrometer and declines thereafter. Overdispersion of breaks is significant above approximately 100 keV/micrometer. Lesion severity, indicated by the level of chromosomal fragments that have not restituted even after long repair times, increases with LET. Similar studies with very low energy 238Pu alpha particles (120 keV/micrometer) reveal higher levels of initial breakage per unit dose, fewer residual fragments and a higher level of misrepair when compared to high energy heavy ions at the same LET. These observations would suggest that track structure is an important factor in genetic damage in addition to LET.  相似文献   

3.
Radiation in low Earth orbit (LEO) is mainly composed of galactic cosmic rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles’ linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and the silicon detectors in various configurations; the preferred passive dosimeters are CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET and thermoluminescence dosimeters (TLDs) as well as optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation field for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the role of high LET radiation in radiobiology, the operational principles for the different dosimeters, the LET spectrum method using CR-39 detectors, the method to combine the results measured with TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured and combined.  相似文献   

4.
The dosimetry of cosmic rays was performed during the first experimental flight of the IBIS facility. Different thermoluminescent detectors (TLD) have been used to measure the contribution of the low linear energy transfer component (LET < 10 keV/micrometer) and plastic nuclear track detectors (PNTD) for the high linear energy tranfer (LET) component. Several parameters of tracks have been measured to determine the LET spectra of primary and secondary charged particles. The total absorbed dose rate (TLD+PNTD) during the flight was 0.23 mGy/day and the dose equivalent rate using the ICRP 60 was 0.52 mSv/day. The corresponding mean quality factor was 2.4. These results are in agreement with those obtained aboard the MIR station with a tissue equivalent proportional counter.  相似文献   

5.
For many years we have been interested in understanding the potential carcinogenic effects of cosmic rays. We have studied the oncogenic effects of cosmic rays with accelerator-produced heavy particle radiation and with a cultured mammalian cell system--C3H10T1/2 cells. Our quantitative data obtained with carbon, neon, silicon, and iron particles showed that RBE is both dose and LET dependent for neoplastic cell transformation. RBE is higher at lower dose, and RBE increases with LET up to about 200 keV/micrometer. In nonproliferation confluent cells, heavy-ion induced transformation damage may not be repairable, although a dose modifying factor of about 1.7 was observed for X-ray radiation. Our recent studies with super-heavy high-energy particles, e.g., 960 MeV/U U235 ions (LET = 1900 keV/micrometer), indicate that these ions with a high inactivation cross-section can cause neoplastic cell transformation. The induction of cell transformation by radiation can be modified with various chemicals. We have found that the presence of DMSO (either during or many days after irradiation) decreased the transformation frequency significantly. It is, therefore, potentially possible to reduce the oncogenic effect of cosmic rays in space through some chemical protection.  相似文献   

6.
G2-chromosome aberrations induced by high-LET radiations.   总被引:1,自引:0,他引:1  
We report measurement of initial G2-chromatid breaks in normal human fibroblasts exposed to various types of high-LET particles. Exponentially growing AG 1522 cells were exposed to gamma rays or heavy ions. Chromosomes were prematurely condensed by calyculin A. Chromatid-type breaks and isochromatid-type breaks were scored separately. The dose response curves for the induction of total chromatid breaks (chromatid-type + isochromatid-type) and chromatid-type breaks were linear for each type of radiation. However, dose response curves for the induction of isochromatid-type breaks were linear for high-LET radiations and linear-quadratic for gamma rays. Relative biological effectiveness (RBE), calculated from total breaks, showed a LET dependent tendency with a peak at 55 keV/micrometer silicon (2.7) or 80 keV/micrometer carbon (2.7) and then decreased with LET (1.5 at 440 keV/micrometer). RBE for chromatid-type break peaked at 55 keV/micrometer (2.4) then decreased rapidly with LET. The RBE of 440 keV/micrometer iron particles was 0.7. The RBE calculated from induction of isochromatid-type breaks was much higher for high-LET radiations. It is concluded that the increased production of isochromatid-type breaks, induced by the densely ionizing track structure, is a signature of high-LET radiation exposure.  相似文献   

7.
We present measurements of LET spectra for near earth orbits with various inclinations and altitudes. A comparison with calculated LET spectra shows that the contribution from direct ionizing galactic cosmic rays is well described by the models. An additional contribution to the spectra originates from stopping protons and from nuclear interactions of particles with material. In the case of an interaction a large amount of energy is deposited in a small volume by target recoils or target fragments. These events will be called short range (SR) events. For a low inclination orbit radiation belt protons are the main source of these events while galactic protons become more important when increasing the inclination to near polar orbits. We show that the contribution of SR events for orbits with low altitude (324 km) and 57 degrees inclination is comparable to that for an orbit with 28 degrees inclination at a high altitude (510 km).  相似文献   

8.
This paper reports on DNA DSB induction in human fibroblasts by iron ions of different energies, namely 5, 1 GeV/u, 414 and 115 MeV/u, in absence or presence of different shields (PMMA, Al and Pb). Measure of DNA DSB was performed by calibrated Pulsed Field Gel Electrophoresis using the fragment counting method. The RBE-LET relationships for unshielded and shielded beams were obtained both in terms of dose average LET and of track average LET. Weak dependence on these parameters was observed for DSB induction. The shielding efficiency, evaluated by the ratio between the cross sections for unshielded and shielded beams, depends not only on the shield type and thickness, but also on the beam energy. Protection is only observed at high iron ions energy, especially at 5 GeV/u, where PMMA shield gives higher protection compared to Al or Pb shields of the same thickness expressed in g/cm2.  相似文献   

9.
Extensive measurements of dose exposure of aircrew have been carried out in recent years using passive detectors on subsonic and supersonic air routes by DIAS (Dublin Institute for Advanced Studies). Studies were based on measurement of LET spectra using nuclear recoils produced in CR-39 nuclear track detectors by high energy neutrons and protons. The detectors were calibrated using energetic heavy ions. Data obtained were compared with the predictions of the EPCARD and CARI-6 codes. Good agreement has been found between the experimental and theoretical values.  相似文献   

10.
Among cosmic rays, the heavy nuclei ranging from carbon to iron provide the principal contribution to the dose equivalent. The LET-distributions and absorbed dose aid dose equivalent have been calculated and are presented as a function of shielding and tissue self-shielding. At solar minimum, outside the magnetosphere, the unshielded dose equivalent of nuclei with atomic number Z > or = 6 is about 47 rem/year. The contribution of the target nuclei adds 7 rem/year. With 4 g/cm2 aluminum shielding, and at a depth of 5 cm in a biological phantom of 30 cm diameter, the respective values are 11 and 10 rem/year. Corresponding dose rates for orbits with various inclinations are presented, as well as the LET distributions of various components of cosmic rays.  相似文献   

11.
The biological effect of heavy ions is best described through the action cross section, as a function of the end-point of interest and the charge and speed of the ion. In track theory this is called the "ion-kill" cross section, for it is the effect produced by a single heavy ion and its delta rays. As with nuclear emulsions the biological track structure passes from the grain count regime to the track width regime to the thindown region with an increase in LET. With biological cells, as with any detector capable of storing sublethal damage, with low LET irradiation the action cross section (in the ion-kill mode) is increasingly obscured by the effect of "gamma-kill", by the influence of overlapping delta rays from neighboring heavy ions. Thus at low LET response is dominated by the gamma-kill mode, so that the RBE approaches 1. The theory requires 4 radiosensitivity parameters for biological detectors, extracted from survival curves at several high LET bombardments passing through the grain count regime, and at high doses. Once these are known the systematic response of biological detectors to all high LET bombardments can be unfolded separating ion kill from gamma kill, predicting the response to a mixed radiation environment, and predicting low dose response even at the level of a single heavy ion. Cell killing parameters are now available for a variety of cell lines. Newly added is a set of parameters for cell transformation.  相似文献   

12.
Detector packages consisting of plastic nuclear track detectors, nuclear emulsions, and theromoluminescence detectors were exposed at different locations inside the space laboratory Spacelab and at the astronauts' body and in different sections of the MIR space station. Total dose, particle fluence rate and linear energy transfer (LET) spectra of heavy ions, number of nuclear disintegrations and fast neutron fluence rates were determined of each exposure. The dose equivalent received by the Payload specialists (PSs) were calculated from the measurements, they range from 190 microSv d-1 to 770 microSv d-1. Finally, a preliminary investigation of results from a particle telescope of two silicon detectors, first used in the last BIORACK mission on STS 76, is reported.  相似文献   

13.
The effects on 17 different structural parameters of mouse small intestine three days after treatment with three types of heavy ion (neon, iron and niobium) are compared, the first two being of particular relevance to space flight. The data for niobium are given in full, showing that changes after niobium ion treatment are not standard and are concentrated in the epithelial compartment, with few of the parameters having a response which is dose dependent. When comparisons are made for the three types of heavy ion, the damage is greatest after neon ion irradiation, implying that the additional non-epithelial damage produced as LET rises from X rays through neutrons to neon ions is not necessarily maintained as LET continues to rise. Further understanding is therefore needed of the balance between changes affecting the vascular and absorptive components of the organ. Variation from group to group is also important, as is variation of strain or gastrointestinal status. All such factors are important in the understanding of changes in multicellular organs after exposure to heavy ion radiation.  相似文献   

14.
The heavy ion component of the cosmic radiation remains problematic to the assessment of risk in manned space flight. The biological effectiveness of HZE particles has yet to be established, particularly with regard to nervous tissue. Using heavy ions accelerated at the AGS of Brookhaven National Laboratory, we study the neurotoxic effects of iron particles. We exposed retinal explants, taken from chick embryos, to determine the dose response relationships for neurite outgrowth. Morphometric techniques were used to evaluate the in vitro effects of 1 GeV/a iron particles (LET 148 keV/micrometer). Iron particles produced a dose-dependent reduction of neurite outgrowth with a maximal effect achieved with a dose of 100 cGy. Doses as low as 10-50 cGy were able to induce reductions of the neurite outgrowth as compared to the control group. Neurite generation is a more sensitive parameter than neurite elongation, suggesting different mechanism of radiation damage in our model. These results showed that low doses/fluences of iron particles could impair the retinal ganglion cells' capacity to generate neurites indicating the highly neurotoxic capability of this heavy charged particle.  相似文献   

15.
Instruments and methods recently used for space radiation dosimetry are reviewed for the purposes of comparison and reference. Passive detection methods mentioned include track-etch, luminescent, nuclear emulsion, and metal foil detectors. These can provide a reliable source of data for all types of radiation, but often require processing that cannot occur in space. Experimental methods of LET determination using TLDs, such as the high temperature peak ratio (HTR) method, are also discussed. Portable readout passive detectors including Pille, MOSFET, and bubble detector systems provide a novel alternative to traditional passive detectors, but research is more limited and their widespread use has yet to be established. Active detectors including DOSTEL, CPDS, RRMD-III, TEPC, R-16, BBND, and the Liulin series are examined for technical details. These instruments allow the determination of dose in real-time, and some can determine LET of incident particles by measuring energy deposition over a known path-length, but size and power consumption limit their practical use for dosimetry. Improved neutron dosimetry and development of a small active or portable readout personnel dosimeter capable of accurate LET determination are important steps for managing the effects of long-term exposure to the space radiation environment.  相似文献   

16.
It has been suggested that it is not simple double-strand breaks (dsb) but the non-reparable breaks which correlate well with the high biological effectiveness of high LET radiations for cell killing (Kelland et al., 1988; Radford, 1986). We have compared the effects of charged particles on cell death in 3 pairs of cell lines which are normal or defective in the repair of DNA dsbs. For the cell lines SL3-147, M10, and SX10 which are deficient in DNA dsb repair, RBE values were close to unity for cell killing induced by charged particles with linear energy transfer (LET) up to 200 keV/micrometer and were even smaller than unity for the LET region greater than 300 keV/micrometer. The inactivation cross section (ICS) increased with LET for all 3 pairs. The ICS of dsb repair deficient mutants was always larger than that of their parents for all the LET ranges, but with increasing LET the difference in ICS between the mutant and its parent became smaller. Since a small difference in ICS remained at LET of about 300 keV/micrometer, dsb repair may still take place at this high LET, even if its role is apparently small. These results suggest that the DNA repair system does not play a major role in protection against the attack of high LET radiations and that a main muse of cell death is non-reparable dsb which are produced at a higher yield compared with low LET radiations. No correlation was observed between DNA content or nuclear area and ICS.  相似文献   

17.
Detector packages were exposed on the European Retrievable Carrier (EURECA) as part of the Biostack experiment inside the Exobiology and Radiation Assembly (ERA) and at several locations around EURECA. The packages consist of different plastic nuclear track detectors, nuclear emulsions and thermoluminescence dosimeters (TLDs). Evaluation of these detectors yields data on absorbed dose and particle and linear energy transfer (LET) spectra. Behind a shielding thickness in front of the detectors of 0.09g cm-2 the doses range between 21.26 Gy and 0.87 Gy depending on the location of the dosimeter. Not all measurement can be explained by calculations.  相似文献   

18.
The lens epithelium is the initiation site for the development of radiation induced cataracts. Radiation in the cortex and nucleus interacts with proteins, while in the epithelium, experimental results reveal mutagenic and cytotoxic effects. It is suggested that incorrectly repaired DNA damage may be lethal in terms of cellular reproduction and also may initiate the development of mutations or transformations in surviving cells. The occurrence of such genetically modified cells may lead to lens opacification. For a quantitative risk estimation for astronauts and space travelers it is necessary to know the relative biological effectiveness (RBE), because the spacial and temporal distribution of initial physical damage induced by cosmic radiation differ significantly from that of X-rays. RBEs for the induction of DNA strand breaks and the efficiency of repair of these breaks were measured in cultured diploid bovine lens epithelial cells exposed to different LET irradiation to either 300 kV X-rays or to heavy ions at the UNILAC accelerator at GSI. Accelerated ions from Z=8 (O) to Z=92 (U) were used. Strand breaks were measured by hydroxyapatite chromatography of alkaline unwound DNA (overall strand breaks). Results showed that DNA damage occurs as a function of dose, of kinetic energy and of LET. For particles having the same LET the severity of the DNA damage increases with dose. For a given particle dose, as the LET rises, the numbers of DNA strand breaks increase to a maximum and then reach a plateau or decrease. Repair kinetics depend on the fluence (irradiation dose). At any LET value, repair is much slower after heavy ion exposure than after X-irradiation. For ions with an LET of less than 10,000 keV micrometers-1 more than 90 percent of the strand breaks induced are repaired within 24 hours. At higher particle fluences, especially for low energetic particles with a very high local density of energy deposition within the particle track, a higher proportion of non-rejoined breaks is found, even after prolonged periods of incubation. At the highest LET value (16,300 keV micrometers-1) no significant repair is observed. These LET-dependencies are consistent with the current mechanistic model for radiation induced cataractogenesis which postulates that genomic damage to the surviving fraction of epithelial cells is responsible for lens opacification.  相似文献   

19.
The aim of this research was to determine the biological effectiveness for early and delayed effects of high energy, high linear energy transfer (LET) charged particles. Survival and delayed reproductive death were measured in AG1522 human fibroblast cells exposed to Fe-ion beams of energies between 0.2 and 1 GeV/n, 0.97 GeV/n Ti-ion and 0.49 GeV/n Si-ion beams. The cells were irradiated at the HIMAC accelerator in Chiba, Japan (0.2 and 0.5 GeV/n Fe and 0.49 GeV/n Si) and at the NASA Space Radiation Laboratory in Brookhaven, USA (1 GeV/n Fe and 0.97 GeV/n Ti ions). The dose-effect curves were measured in the dose range between 0.25 and 2 Gy. For comparison cells were exposed to 60Co gamma rays. Analysis of the dose-effect curves show that all the heavy ion beams induce inactivation and delayed reproductive death more effectively than 60Co gamma rays. The only exception is the 0.2 GeV/n Fe-ion beam at low doses. The progeny of the irradiated cells show delayed damage in the form of reproductive death with all the heavy ion beams with the 1 GeV/n Fe-ion beam being the most effective. The relative biological effectiveness at low doses of the iron beams is highest for LET values between 140 and 200 keV/micrometers with values of 1.6 and 3 for early and delayed reproductive death, respectively. Analysis of the fluence-effect curves shows that the cross-sections for early and delayed inactivation increase with increasing LET up to 442 keV/micrometers.  相似文献   

20.
The risk of radiation-induced cancer to space travelers outside the earth's magnetosphere will be of concern on missions to the Moon and beyond to Mars. High energy galactic cosmic rays with high charge (HZE particles) will penetrate the spacecraft and the bodies of the astronauts, sometimes fragmenting into nuclear secondary species of lower charge but always ionizing densely, thus causing cellular damage which may lead to malignant transformation. To quantitate this risk, the concept of dose equivalent (in which a quality factor Q as a function of LET is assumed) may not be adequate, since different particles of the same LET may have different efficiencies for tumor induction. Also, RBE values on which quality factors are based depend on response to low-LET radiation at low doses, a very difficult region for which to obtain reliable experimental data. Thus, we introduce a new concept, a fluence-related risk coefficient (F), which is the risk of a cancer per unit particle fluence and which we call the risk cross section. The total risk is the sum of the risk from each particle type: sigma i integral Fi(Li) phi i(Li) dLi, where Li is the LET and phi i(Li) is the fluence-LET spectrum of the ith particle type. As an example, tumor prevalence data in mice are used to estimate the probability of mouse Harderian gland tumor induction per year on an extra-magnetospheric mission inside an idealized shielding configuration of a spherical aluminum shell 1 g/cm2 thick. The combined shielding code BRYNTRN/GCR is used to generate the LET spectra at the center of the sphere. Results indicate a yearly prevalence at solar minimum conditions of 0.06, with 60% of this arising from charge components with Z between 10 and 28, and two-thirds of the contribution arising from LET components between 10 and 200 keV/micrometers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号