首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
We present a large area, balloon borne, NaI(Tl) detector for low-energy gamma rays with temporal signature : FIGARO.The main detector is a mosaic of 12 NaI(Tl) tiles 22.5 × 15 × 5 cm, for a total geometric area of 4050 cm2.In the energy band 140 keV - 6 MeV, the expected background counting rate at float altitude is in the range of two to three thousands counts per second.For pulsar analysis the expected 3δ sensitivity for 5 hours exposition time is 2.5 10?4 ph/cm2.s.MeV (150–500 keV) 1.5 10?4 ph/cm2.s.MeV (1–6 MeV). This performance, together with the large effective area and the relatively short duration of a balloon flight, make FIGARO particularly suitable for the identification of sources by means of temporal analysis.For objectives in the Northern sky, including the Crab pulsar, a transmediterranean flight is planned for the summer of 1982 ; a Southern mission is scheduled in Brazil for the fall of 1983 (Vela, PSR 1822-09).  相似文献   

3.
The balloon payload HEXE A) is designed to observe cosmic X-ray sources in the energy range 20–250 keV. Its detectors are ‘Phoswich’ scintillators with a total sensitive area of 2300 cm2 and a cooled Ge solid state detector with an area of 100 cm2 [1]. The instrument was flown successfully in 1980 and 1981 from Palestine, Texas.Here we describe the control of the instrument and guidance of the telescope as well as the method of data retrieval and real time analysis. These tasks are performed by a ground based minicomputer (HP 1000) and onboard microprocessors (M 6800) which are linked together by data and command telemetry.  相似文献   

4.
The Passepartout sounding balloon transportation system for low-mass (<<1200 g) experiments or hardware for validation to an altitude of 35 km is described. We present the general flight configuration, set-up of the flight control system, environmental and position sensors, power system, buoyancy considerations as well as the ground control infrastructure including recovery operations. In the telemetry and command module the integrated airborne computer is able to control the experiment, transmit telemetry and environmental data and allows for a duplex communication to a control centre for tele-commanding. The experiment module is mounted below the telemetry and command module and can either work as a standalone system or be controlled by the airborne computer. This spacing between experiment- and control unit allows for a high flexibility in the experiment design. After a parachute landing, the on-board satellite based recovery subsystems allow for a rapid tracking and recovery of the telemetry and command module and the experiment. We discuss flight data and lessons learned from two representative flights with research payloads.  相似文献   

5.
Development overview of the revised NASA Ultra Long Duration Balloon   总被引:1,自引:0,他引:1  
The desire for longer duration stratospheric flights at constant float altitudes for heavy payloads has been the focus of the development of the National Aeronautics and Space Administration’s (NASA) Ultra Long Duration Balloon (ULDB) effort. Recent efforts have focused on ground testing and analysis to understand the previously observed issue of balloon deployment. A revised approach to the pumpkin balloon design has been tested through ground testing of model balloons and through two test flights. The design approach does not require foreshortening, and will significantly reduce the balloon handling during manufacture reducing the chances of inducing damage to the envelope. Successful ground testing of model balloons lead to the fabrication and test flight of a ∼176,000 m3 (∼6.2 MCF – Million Cubic Foot) balloon. Pre-flight analytical predictions predicted that the proposed flight balloon design to be stable and should fully deploy. This paper provides an overview of this first test flight of the revised Ultra Long Duration Balloon design which was a short domestic test flight from Ft. Sumner, NM, USA. This balloon fully deployed, but developed a leak under pressurization. After an extensive investigation to the cause of the leak, a second test flight balloon was fabricated. This ∼176,000 m3 (∼6.2 MCF) balloon was flown from Kiruna, Sweden in June of 2006. Flight results for both test flights, including flight performance are presented.  相似文献   

6.
The VHF Omnidirectional Range (VOR) system is a primary navigational aid to aircraft in the United States. Although the quantity of stations in the United States exceeds that of other areas, VOR stations are found all over the world. An inexpensive balloon navigational package that uses the existing VOR system has been developed. It employs the principle of triangulation between stations to yield position information. The station selection can be changed by telemetry command during the balloon flight in order to maximize triangulation accuracy and to minimize effects of weak signals. The VOR radials are part of the telemetry transmitted from the balloon package. Preliminary results from several flights in Palestine, Texas indicate that this system may be a viable backup or substitute for the OMEGA system commonly used. Typical accuracy of the down point prediction has been ± 1 mile.  相似文献   

7.
The Polar Balloon Atmospheric Composition Experiment (P-BACE) is a new generation of neutral gas mass spectrometer based on the time-of-flight principle. P-BACE is the scientific experiment on the Mars Environment Analog Platform (MEAP) flown successfully on a balloon mission in summer 2008. The MEAP mission was flown with a 334,000 m3 helium balloon in the stratosphere on a semicircular trajectory from northern Sweden around the North Pole to Canada using the summer northern hemispheric wind current. The atmospheric conditions at an atmospheric altitude of 35–40 km are remarkably similar to those on the surface of Mars and thus the balloon mission was an ideal testbed for our mass spectrometer P-BACE. Originally this instrument was designed for in situ measurements of the chemical composition of the Martian atmosphere.P-BACE has a unique mass range from 0 to 1000 amu/q with a mass resolution mm (FWHM) > 1000, and the dynamic range is at least six orders of magnitude. During this experiment, the acquisition of one mass spectrum is a sum of 65,535 single spectra, recorded in a time frame of 66 s.The balloon mission lasted 5 days and had successfully demonstrated the functionality of the P-BACE instrument during flight conditions. We had recorded more than 4500 mass spectra. With little modifications, P-BACE can be used on a planetary mission for Mars, but for example also for Venus or Mercury, if placed on a satellite.  相似文献   

8.
We describe the fabrication and flight performance of a balloon-borne large area hard X-ray (20–100 keV) telescope for spectral studies of discrete cosmic X-ray sources. The telescope consists of two multi-wire Xenon filled proportional counters of effective area 1200 cm2 each, mounted on an orientable platform. It can be pre-programmed to track any celestial source with a pointing accuracy of 0.5 degrees. For one hour of observation the telescope has a 5 σ detection sensitivity of 10−5 ph cm−2 s−1. The laboratory test results and the performance in a series of balloon flights conducted in 1984–1986 period is discussed and the preliminary results obtained for some X-ray sources are presented.  相似文献   

9.
10.
A large area (6000 cm2) actively shielded low energy gamma-ray telescope is going to be built by an Anglo-Italian collaboration. The telescope, named ZEBRA, will be capable of producing images of the X and gamma ray sky in the energy range 0.015–20 MeV with an intrinsic angular resolution of a few tenths of a degree. A prototype detector has been built in order to experimentally study the main characteristics of the detection plane. The preliminary results obtained during a balloon flight from Trapani, Sicily in July 1981 are presented.  相似文献   

11.
The essential reason of the lobed-pumpkin shaped super-pressure balloon to withstand against the high pressure is that the local curvature of the balloon film is kept small. Recently, it has been found that the small local curvature can also be obtained if the balloon is covered by a diamond-shaped net with a vertically elongated shape. The development of the super-pressure balloon using this method was started from a 3-m balloon with a polyethylene film covered by a net using Kevlar ropes. The ground inflation test showed the expected high burst pressure. Then, a 6-m and a 12-m balloon using a polyethylene film and a net using the Vectran were developed and stable deployment was checked through the ground inflation tests. The flight test of a 3000 m3 balloon was performed in 2013 and shown to resist a pressure of at least 400 Pa. In the future, after testing a new design to relax a possible stress concentration around the polar area, test flights of scaled balloons will be performed gradually enlarging their size. The goal is to launch a 300,000 m3 super-pressure balloon.  相似文献   

12.
Established in 1971, the National Balloon Facility operated by TIFR in Hyderabad, India, is a unique facility in the country, which provides a complete solution in scientific ballooning. It is also one of its kind in the world since it combines both, the in-house balloon production and a complete flight support for scientific ballooning. With a large team working through out the year to design, fabricate and launch scientific balloons, the Hyderabad Facility is a unique centre of expertise where the balloon design, research and development, the production and launch facilities are located under one roof. Our balloons are manufactured from 100% indigenous components. The mission specific balloon design, high reliability control and support instrumentation, in-house competence in tracking, telemetry, telecommand, data processing, system design and mechanics is its hallmark. In the past few years, we have executed a major programme of upgradation of different components of balloon production, telemetry and telecommand hardware and various support facilities. This paper focuses on our increased capability of balloon production of large sizes up to 780,000 m3 using Antrix film, development of high strength balloon load tapes with the breaking strength of 182 kg, and the recent introduction of S-band telemetry and a commandable timer cut-off unit in the flight hardware. A summary of the various flights conducted in recent years will be presented along with the plans for new facilities.  相似文献   

13.
14.
The HXR79 hard X-Ray experiment was flown the August 26th 1979 from the Milo Base (Sicily, Italy) and a 27-hour flight was achieved. The scientific payload consisted of two Multiwire Spectroscopic Proportional Counters (MWSPC) with 900 cm2 sensitive geometric area each, in the hard X-Ray range (16–180 keV). A single drift scan was performed on the Crab Nebula region after the balloon reached the flotation point (2.9 mbar). The observation gave a maximum counting rate of about 25 counts/s superimposed on a background of about 75 counts/s. The Crab power-law spectrum was observed, and these data provide evidence for a line emission enhancement around 70 keV.  相似文献   

15.
The Crab was observed in a balloon flight from Palestine/Texas on 9/28/81 at hard X-ray energies (20–200 keV). The light curve is significantly sharper than reported previously for this energy range. The pulse-averaged as well as the interpulse spectra show breaks in our energy-range. The variation of spectral index across the pulse has an amplitude similar to that found at lower energies by OSO-8 and larger than reported by HEAO-1 A4 at hard X-rays. For a sharp emission line at 77 keV a 99% upper limit of 1.0*10−3 photons/ cm2 sec can be placed, a factor of 4 lower than line fluxes reported previously. Pulse-shape fits to the optical, X-ray, hard X-ray and gamma ray light-curves reveal a consistent picture of the origin of the interpulse and off-pulse emission, the breaks in the spectra and the variation of spectral index, providing arguments against a thermal component and also a polar cap emission model for NP0532.  相似文献   

16.
Absolute solar UV spectra were obtained with a 14m spectrometer on a balloon flight from Palestine, Texas on September 23, 1981. This balloon reached a float altitude of 39 km at solar noon. The ozone density profiles derived from these spectra are discussed. The measurements are compared with data obtained from the same calibrated instrument flown in 1976 at solar minimum.  相似文献   

17.
We have developed a new detector using thin lanthanum bromide crystal (32 × 3 mm) for use in X-ray astronomy. The instrument was launched in high altitude balloon flight on two different occasions, December 21, 2007, which reached a ceiling altitude of 4.3 mbs and April 25, 2008 reaching a ceiling altitude 2.8 mbs. The observed background counting rate at the ceiling altitude of 4 mbs was ∼4 × 10−3 ct cm−2 s−1 keV−1 sr−1. This paper describes the details of the experiment, the detector characteristics, and the background behaviour at the ceiling altitude.  相似文献   

18.
This paper describes the design, fabrication and testing of a full scale prototype balloon intended for long duration flight in the upper atmosphere of Venus. The balloon is 5.5 m in diameter and is designed to carry a 45 kg payload at an altitude of 55 km. The balloon material is a 180 g/m2 multi-component laminate comprised of the following layers bonded together from outside to inside: aluminized Teflon film, aluminized Mylar film, Vectran fabric and a polyurethane coating. This construction provides the required balloon functional characteristics of low gas permeability, sulfuric acid resistance and high strength for superpressure operation. The design burst superpressure is 39,200 Pa which is predicted to be 3.3 times the worst case value expected during flight at the highest solar irradiance in the mission profile. The prototype is constructed from 16 gores with bi-taped seams employing a sulfuric acid resistant adhesive on the outside. Material coupon tests were performed to evaluate the optical and mechanical characteristics of the laminate. These were followed by full prototype tests for inflation, leakage and sulfuric acid tolerance. The results confirmed the suitability of this balloon design for use at Venus in a long duration mission. The various data are presented and the implications for mission design and operation are discussed.  相似文献   

19.
The Advanced Thin Ionization Calorimeter (ATIC) experiment is designed to investigate the charge composition and energy spectra of primary cosmic rays over the energy range from about 1011 to 1014 eV during Long Duration Balloon (LDB) flights from McMurdo, Antarctica. Currently, analysis from the ATIC-1 test flight and ATIC-2 science flight is underway and preparation for a second science flight is in progress. Charge identification of the incident cosmic ray is accomplished, primarily, by a pixilated Silicon Matrix detector located at the very top of the instrument. While it has been shown that the Silicon Matrix detector provides good charge identification even in the presence of electromagnetic shower backscatter from the calorimeter, the detector only measures the charge once. In this paper, we examine use of the top scintillator hodoscope detector to provide a second measure of the cosmic ray charge and, thus, improve the ATIC charge identification.  相似文献   

20.
A large (1455 cm2) hard X-ray telescope was successfully launched aboard a stratospheric balloon on October 4, 1980. During this flight four galactic X-ray sources were observed, namely the transient recurrent X-ray pulsar A0535+26, the Crab Nebula, Cygnus X-1 and X Persei. Here we report the results on the latter two sources. From Cygnus X-1 we measured a photon flux in the band 30 to 200 keV, of 3.5 × 10?2 photons cm?2 which is 6.5 times lower than that recieved from the source in a “low” intensity state in the same energy band. In addition, the photon spectrum in the same energy band was very soft and consistent with a power law with photon index α = 2.71 ± 0.14. Even if a simultaneous observation of the source at lower energies was not available, our data strongly suggest that we observed the source during a “high” intensity state. We report also positive detection in the band 30 to 200 keV of the low luminosity X-ray pulsar X Persei. In its spectrum we confirm the presence of a hard X-ray tail consistent with a power law (photon index α = 2.17 ± 0.42).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号