首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
We describe the differential energy spectrum of trapped particles measured by a solid-state charged particle telescope in the mid-deck of the Space Shuttle during the period of solar maximum. The telescope was flown in two high altitude flights at 28.5° and 57° inclination. Assuming, as is normally done, that the variations of Shuttle orientation during the missions lead to average isotropic incident spectra, the observed spectrum disagrees significantly from AP8 model calculations. This indicates the need to take into consideration the variations of solid-angle direction relative to the magnetic field. The measurements show that there is a very significant flux of secondary light ions. The energy spectra of these ions does not agree with the production spectrum from radiation transport calculations based on omni-directional AP8 Max model as an input energy spectrum.

We also describe measurements of linear energy transfer spectra using a tissue equivalent proportional counter (TEPC) flown both in the mid-deck and the payload bay of the Space Shuttle. Comparisons are made between linear energy transfer spectral measurements AP8 model-based radiation transport predictions, and thermoluminescent dosimeter (TLD) measurements. The absorbed dose-rate measurements using TLD's are roughly 25% lower than the TEPC-measured dose rate measurements.  相似文献   


3.
The dosimetry of cosmic rays was performed during the first experimental flight of the IBIS facility. Different thermoluminescent detectors (TLD) have been used to measure the contribution of the low linear energy transfer component (LET < 10 keV/micrometer) and plastic nuclear track detectors (PNTD) for the high linear energy tranfer (LET) component. Several parameters of tracks have been measured to determine the LET spectra of primary and secondary charged particles. The total absorbed dose rate (TLD+PNTD) during the flight was 0.23 mGy/day and the dose equivalent rate using the ICRP 60 was 0.52 mSv/day. The corresponding mean quality factor was 2.4. These results are in agreement with those obtained aboard the MIR station with a tissue equivalent proportional counter.  相似文献   

4.
Detector packages were exposed on the European Retrievable Carrier (EURECA) as part of the Biostack experiment inside the Exobiology and Radiation Assembly (ERA) and at several locations around EURECA. The packages consist of different plastic nuclear track detectors, nuclear emulsions and thermoluminescence dosimeters (TLDs). Evaluation of these detectors yields data on absorbed dose and particle and linear energy transfer (LET) spectra. Behind a shielding thickness in front of the detectors of 0.09g cm-2 the doses range between 21.26 Gy and 0.87 Gy depending on the location of the dosimeter. Not all measurement can be explained by calculations.  相似文献   

5.
Described is the Liulin-5 active dosimetric telescope designed for measurement of the space radiation dose depth-distribution in a human phantom on the Russian Segment of the International Space Station (ISS). The Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The MATROSHKA-R project is aimed to study the depth-dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is a long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different compartments. Energy deposition spectra, linear energy transfer spectra, and flux and dose rates for charged particles will be measured simultaneously with near real time resolution at different depths of the phantom by means of three silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, which verify the models of radiation environment in low Earth orbit. Presented are the test results of the prototype unit. Liulin-5 will be flown on the ISS in the year 2003.  相似文献   

6.
Liulin-5 is a particle telescope developed for the investigation of the radiation environment within the Russian spherical tissue-equivalent phantom on the International Space Station (ISS). Liulin-5 experiment is conducted aboard the Russian segment of ISS since 28 June 2007 as an adherent part of the international project MATROSHKA-R. The main objective of Liulin-5 experiment is to study the depth-dose distribution of the different components of the orbital radiation field in a human phantom. Additional objectives are mapping of the radiation environment in the phantom and its variations with time and orbital parameters (such as solar cycle, solar flare events, inclination and altitude). Liulin-5 is an active instrument, capable to provide real-time radiation data for the particle flux and dose rates, energy deposition and LET spectra. Data are recorded automatically on memory cards, periodically transported to ground by returning vehicles. In this report we present some first results from data analysis including energy deposition spectra, absorbed dose, dose rate and flux distribution measured simultaneously at 3 different depths of phantom’s radial channel and linear energy transfer (LET) spectrum. Data discussed are for the period July 2007–April 2008.  相似文献   

7.
Described is the Liulin-5 experiment and instrumentation, developed for investigation of the space radiation doses depth distribution in a human phantom on the Russian Segment of the International Space Station (ISS). Liulin-5 experiment is a part of the international project MATROSHKA-R on ISS. The experiment MATROSHKA-R is aimed to study the depth dose distribution at the sites of critical organs of the human body, using models of human body-anthropomorphic and spherical tissue-equivalent phantoms. The aim of Liulin-5 experiment is long term (4-5 years) investigation of the radiation environment dynamics inside the spherical tissue-equivalent phantom, mounted in different places of the Russian Segment of ISS. Energy deposition spectra, linear energy transfer spectra, flux and dose rates for protons and the biologically-relevant heavy ion components of the galactic cosmic radiation will be measured simultaneously with near real time resolution at different depths of the phantom by a telescope of silicon detectors. Data obtained together with data from other active and passive dosimeters will be used to estimate the radiation risk to the crewmembers, verify the models of radiation environment in low Earth orbit, validate body transport model and correlate organ level dose to skin dose. Presented are the test results of the prototype unit. The spherical phantom will be flown on the ISS in 2004 year and Liulin-5 experiment is planned for 2005 year.  相似文献   

8.
Galactic cosmic radiation model and its applications.   总被引:2,自引:0,他引:2  
A model for the differential energy spectra of galactic cosmic radiation as a function of solar activity is described. It is based on the standard diffusion-convection theory of solar modulation. Estimates of the modulation potential based on fitting this theory to observed spectral measurements from 1954 to 1989 are correlated to the Climax neutron counting rates and to the sunspot numbers at earlier times taking into account the polarity of the interplanetary magnetic field at the time of observations. These regression lines then provide a method for predicting the modulation at later times. The results of this model are quantitatively compared to a similar Moscow State University (MSU) model. These model cosmic ray spectra are used to predict the linear energy transfer spectra, differential energy spectra of light (charge < or = 2) ions, and single event upset rates in memory devices. These calculations are compared to observations made aboard the Space Shuttle.  相似文献   

9.
To measure the radiation environment in the Spacelab (SL) module and on the pallet, a set of passive and active radiation detectors was flown as part of the Verification Flight Instrumentation (VFI). SL 1 carried 4 passive and 2 active detector packages which, with the data from the 26 passive detectors of Experiment INS006, provided a comprehensive survey of the radiation environment within the spacecraft. SL 2 carried 2 passive VFI units on the pallet. Thermoluminescent dosimeters (TLDs) measured the low linear energy transfer (LET) dose component; the HZE fluence and LET spectra were mapped with CR-39 track detectors; thermal and epithermal neutrons were measured with the use of fission foils; metal samples analyzed by gamma ray spectroscopy measured low levels of several activation lines. The TLDs registered from 97 to 143 mrad in the SL 1 module. Dose equivalents of 330±70 mrem in the SL 1 module and 537±37 mrem on the SL 2 pallet were measured. The active units in the SL 1 module each contained an integrating tissue-equivalent ion chamber and two differently-shielded xenon-filled proportional counters. The ion chambers accumulated 125 and 128 mrads for the mission with 17 and 12 mrads accumulated during passages through the South Atlantic Anomaly (SAA). The proportional counter rates (1 cps at sea level) were 100 cps in the middle of the SAA (mostly protons), 35 cps at large geomagnetic latitudes (cosmic rays) and 100 cps in the South Horn of the electron belts (mostly bremsstrahlung). Detailed results of the measurements and comparison with calculated values are described.  相似文献   

10.
We have flown two new charged particle detectors in five recent Shuttle flights. In this paper we report on the dose rate, equivalent dose rate, and radiation quality factor for trapped protons and cosmic radiation separately. A comparison of the integral linear energy transfer (LET) spectra with recent transport code calculations show significant disagreement. Using the calculated dose rate from the omni-directional AP8MAX model with IGRF reference magnetic field epoch 1970, and observed dose rate as a function of (averaged over all geographic latitude) and longitude, we have determined the westward drift of the South Atlantic anomaly. We have also studied the east-west effect, and observed a 'second' radiation belt. A comparison of the galactic cosmic radiation lineal energy transfer spectra with model calculations shows disagreement comparable to those of the trapped protons.  相似文献   

11.
In analyzing charged particle spectra in space due to galactic cosmic rays (GCR) and solar particle events (SPE), the conversion of particle energy spectra into linear energy transfer (LET) distributions is a convenient guide in assessing biologically significant components of these spectra. The mapping of LET to energy is triple valued and can be defined only on open energy subintervals where the derivative of LET with respect to energy is not zero. Presented here is a well-defined numerical procedure which allows for the generation of LET spectra on the open energy subintervals where, in spite of their singular nature, the spectra are integrable. The efficiency of the numerical procedures is demonstrated by providing examples of computed differential and integral LET spectra and their equilibrium components for historically large SPEs and 1977 solar minimum GCR environments. Due to the biological significance of tissue, all simulations are done with tissue as the target material.  相似文献   

12.
The solar particle events (SPE) will contain a primary alpha particle component, representing a possible increase in the potential risk to astronauts during an SPE over the often studied proton component. We discuss the physical interactions of alpha particles important in describing the transport of these particles through spacecraft and body shielding. Models of light ion reactions are presented and their effects on energy and linear energy transfer (LET) spectra in shielding discussed. We present predictions of particle spectra, dose, and dose equivalent in organs of interest for SPE spectra typical of those occurring in recent solar cycles. The large events of solar cycle 19 are found to have substantial increase in biological risk from alpha particles, including a large increase in secondary neutron production from alpha particle breakup.  相似文献   

13.
Effect of HZE particles and space hadrons on bacteriophages.   总被引:2,自引:0,他引:2  
The effect of high energy (HZE) particles and high energy hadrons on T4Br+ bacteriophage was analyzed. The experiments were done in orbital flight, on high mountains, on an accelerator, and with an alpha particle source. We studied the survival rate of the bacteriophage, the mutation frequency, the mutation spectrum and the revertability under the action of chemical mutagens with a known mechanism of action on DNA. It was found that the biological efficiency of HZE particles and high energy hadrons is greater than that of gamma radiation. The spectra of mutations produced by these mutations and the mechanisms of their action are also different. These effects were local, because of the mode of interaction of the radiant energy with biological objects, and depended on the linear energy transfer (LET). The modes have now been experimentally defined.  相似文献   

14.
The Liulin-5 experiment is a part of the international project MATROSHKA-R on the Russian segment of the ISS, which uses a tissue-equivalent spherical phantom equipped with a set of radiation detectors. The objective of the MATROSHKA-R project is to provide depth dose distribution of the radiation field inside the sphere in order to get more information on the distribution of dose in a human body. Liulin-5 is a charged particle telescope using three silicon detectors. It measures time resolved energy deposition spectra, linear energy transfer (LET) spectra, particle flux, and absorbed doses of electrons, protons and heavy ions, simultaneously at three depths along the radius of the phantom. Measurements during the minimum of the solar activity in cycle 23 show that the average absorbed daily doses at 40 mm depth in the phantom are between 180 μGy/day and 220 μGy/day. The absorbed doses at 165 mm depth in the phantom decrease by a factor of 1.6–1.8 compared to the doses at 40 mm depth due to the self-shielding of the phantom from trapped protons. The average dose equivalent at 40 mm depth is 590 ± 32 μSV/day and the galactic cosmic rays (GCR) contribute at least 70% of the total dose equivalent at that depth. Shown is that due to the South Atlantic Anomaly (SAA) trapped protons asymmetry and the direction of Liulin-5 lowest shielding zone the dose rates on ascending and descending nodes in SAA are different. The data obtained are compared to data from other radiation detectors on ISS.  相似文献   

15.
Estimation of exposure due to environmental and other sources of radiations of high-LET and low-LET is of interest in radiobiology and radiation protection for risk assessment. To account for the differences in effectiveness of different types of radiations various parameters have been used. However, the relative inadequacy of the commonly used parameters, including dose, fluence, linear energy transfer, lineal energy, specific energy and quality factor, has been made manifest by the biological importance of the microscopic track structure and primary modes of interaction. Monte Carlo track structure simulations have been used to calculate the frequency of energy deposition by radiations of high- and low-LET in target sizes similar to DNA and higher order genomic structure. Tracks of monoenergetic heavy ions and electrons were constructed by following the molecular interaction-by-interaction histories of the particles down to 10 eV. Subsequently, geometrical models of these assumed biological targets were randomly exposed to the radiation tracks and the frequency of energy depositions obtained were normalized to unit dose in unit density liquid water (l0(3) kg m-3). From these data and a more sophisticated model of the DNA, absolute yields of both single- and double-strand breaks expressed in number of breaks per dalton per Gray were obtained and compared with the measured yields. The relative biological effectiveness (RBE) for energy depositions in cylindrical targets has been calculated using 100 keV electrons as the reference radiation assuming the electron track-ends contribution is similar to that in 250 kV X-ray or Co60 gamma-ray irradiations.  相似文献   

16.
The Mir station has been in a 51.65 degrees inclination orbit since March 1986. In March 1995, the first US astronaut flew on the Mir-18 mission and returned on the Space Shuttle in July 1995. Since then three additional US astronauts have stayed on orbit for up to 6 months. Since the return of the first US astronaut, both the Spektr and Priroda modules have docked with Mir station, altering the mass shielding distribution. Radiation measurements, including the direct comparison of US and Russian absorbed dose rates in the Base Block of the Mir station, were made during the Mir-18 and -19 missions. There is a significant variation of dose rates across the core module; the six locations sampled showed a variation of a factor of nearly two. A tissue equivalent proportional counter (TEPC) measured a total absorbed dose rate of 300 microGy/day, roughly equally divided between the rate due to trapped protons from the South Atlantic Anomaly (SAA) and galactic cosmic radiation (GCR). This dose rate is about a factor of two lower than the rate measured by the thinly shielded (0.5 g cm-2 of Al) operational ion chamber (R-16), and about 3/2 of the rate of the more heavily shielded (3.5 g cm-2 of Al) ion chamber. This is due to the differences in the mass shielding properties at the location of these detectors. A comparison of integral linear energy transfer (LET) spectra measured by TEPC and plastic nuclear track detectors (PNTDs) deployed side by side are in remarkable agreement in the LET region of 15-1000 keV/micrometer, where the PNTDs are fully efficient. The average quality factor, using the ICRP-26 definition, was 2.6, which is higher than normally used. There is excellent agreement between the measured GCR dose rate and model calculations, but this is not true for trapped protons. The measured Mir-18 crew skin dose equivalent rate was 1133 microSv/day. Using the skin dose rate and anatomical models, we have estimated the blood-forming organ (BFO) dose rate and the maximum stay time in orbit for International Space Station crew members.  相似文献   

17.
An extensive model analysis of plastic track detector measurements of high-LET particles on the Space Shuttle has been performed. Three shuttle flights: STS-51F (low-altitude, high-inclination), STS-51J (high-altitude, low-inclination), and STS-61C (low-altitude, low-inclination) are considered. The model includes contributions from trapped protons and galactic cosmic radiation, as well as target secondary particles. Target secondaries, expected to be of importance in thickly shielded space environments, are found to be a significant component of the measured LET (linear energy transfer) spectra.  相似文献   

18.
Amongst the great variety of heavy particles present in the galactic and solar cosmic ray spectra, hydrogen and helium nuclei are significantly more abundant than all other heavier ions and, as such, represent a major radiation hazard to humans in space. Experimental data have suggested that differences in relative biological effectiveness (RBE) exist between the two species at the same value of linear energy transfer (LET). This has consequences for heavily ionising radiation protection procedures, which currently still assume a simple dependence of radiation quality on LET. By analysing the secondary electron (delta-ray) emission spectra of protons and alpha particles, in terms of the spatial characteristics of energy deposition in cellular targets and the likelihood of complex lesion formation, a numerical quantity representing biological effectiveness is generated. When expressed relative to a reference radiation, this quantity is found to differ for protons and a particles of the same LET, demonstrating not only the ion-specific nature of RBE but also the inadequacy of specifying radiation quality as a function of LET only. Such a method for numerically assessing radiation quality may have implications for procedures for heavy ion protection in space at low doses and for understanding the initial mechanisms of radiation action.  相似文献   

19.
We review the recent advances in the field of energy transfer and dissipation in solar flares. New observations and theoretical results have been obtained during the SMY and discussed in several workshops. Important new results have been provided by imaging hard X-ray and radio observations, high resolution spectra in the soft X-ray range, polarization measurements and combined optical, gamma- and X-ray data. We summarize results on the following topics: a) interpretation of hard X-ray bursts; b) heating and cooling of X-ray flare plasmas; c) chromospheric heating and evaporation; d) white-light flares. An overall picture of the importance of transfer processes is given, together with prospects for development of future research topics.  相似文献   

20.
基于Geant 4软件建立一种用于计算航天器内部充电所产生电场的方法.分析载有IDM仪器的CRRES卫星当时所处的空间电子环境,使用该方法进行内部充电模拟,并将模拟结果与IDM仪器所测得的放电脉冲数据进行对比,不仅验证了该方法的有效性,更重要的是深入认识了引起航天器内部充电的空间环境特征以及材料特性对充放电效应的影响.介质内最大电场的模拟计算结果与CRRES卫星实际观测到的放电现象吻合;在材料的各项参数中,与辐射感应电导率有关的kp系数对稳态电场有很大影响,为了定量研究内部充电效应,需要在实验室精确地测定kp系数;材料的暗电导率、密度以及材料的分子构成等也与内部充电效应有关,对这些参数细致地研究有助于对内部充电效应的认识.   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号