首页 | 本学科首页   官方微博 | 高级检索  
     

颞骨蜂房气化程度对血管性耳鸣的影响
引用本文:杨洁萌,王丽珍,田山,刘兆会,樊瑜波. 颞骨蜂房气化程度对血管性耳鸣的影响[J]. 北京航空航天大学学报, 2016, 42(3): 583-587. DOI: 10.13700/j.bh.1001-5965.2015.0140
作者姓名:杨洁萌  王丽珍  田山  刘兆会  樊瑜波
作者单位:1.北京航空航天大学生物与医学工程学院, 北京 100083
基金项目:国家自然科学基金(81371545;11421202),首都医科大学基础-临床科研合作基金(13JL03)National Natural Science Foundation of China(81371545
摘    要:为了研究颞骨蜂房气化程度与血管性耳鸣之间的生物力学关系,本文基于典型的血管性耳鸣患者的数据进行了计算分析。首先,基于血管性耳鸣患者CT图像分别建立颞骨蜂房的基础气化和过度气化2种气化程度的三维几何模型。然后,将三维几何模型分别导入Hypermesh软件中并以四面体单元进行网格划分,生成可计算的三维有限元(FE)模型。再将三维有限元模型导入Virtual.Lab Acoustics软件中,加载相同速度边界条件,计算模型的声压幅值响应。最后,以前庭处检测的声压幅值作为计算结果。由2个模型生物力学数值模拟计算的结果,可以发现频率为250 Hz时经气化模型产生的声压幅值比基础模型的值低3.02 dB。经过气化模型产生的声压幅值小于基础模型,且在相同频率下2个模型间的声压幅值差异可被血管性耳鸣患者察觉。这一结论可以尝试为临床创新治疗血管性耳鸣提供新的理论依据。 

关 键 词:血管性耳鸣   乙状窦   颞骨蜂房   气化程度   影响
收稿时间:2015-03-13

Effect of pneumatization degree of temporal bone air cell on vascular pulsatile tinnitus
YANG Jiemeng,WANG Lizhen,TIAN Shan,LIU Zhaohui,FAN Yubo. Effect of pneumatization degree of temporal bone air cell on vascular pulsatile tinnitus[J]. Journal of Beijing University of Aeronautics and Astronautics, 2016, 42(3): 583-587. DOI: 10.13700/j.bh.1001-5965.2015.0140
Authors:YANG Jiemeng  WANG Lizhen  TIAN Shan  LIU Zhaohui  FAN Yubo
Abstract:To quantify the biomechanic relationship between the degree of pneumatization in the temporal bone air cell and vascular pulsatile tinnitus, the numerical simulation upon a typical vascular pulsatile tinnitus patient's data were conducted in this study. First, the two 3D geometric models of temporal bone air cell, including the basic model and the over-pneumatization model, were developed based on the same patient's CT images individually. Second, the models were meshed with tetrahedral elements by Hypermesh, and computed 3D finite element (FE) models were generated. Then two FE models were imported into Virtual. Lab Acoustics. Third, the same velocity boundary condition was loaded, and then the sound intensity of vibration response was achieved by Virtual. Lab Acoustics. Finally, the sound intensity amplitude at the vestibule was computed. A comparative analysis of two models was done based on the biomechanical numerical simulations. It was shown that the sound intensity amplitude of the over-pneumatization model was 3.02 dB lower than the basic one at 250 Hz. It was found that the difference of amplitude between two models could be perceived by vascular pulsatile tinnitus patient under the condition of same frequency. These would provide a new theoretical basis for innovative treatment of vascular pulsatile tinnitus.
Keywords:vascular pulsatile tinnitus  sigmoid sinus  temporal bone air cell  pneumatization degree  effect
本文献已被 万方数据 等数据库收录!
点击此处可从《北京航空航天大学学报》浏览原始摘要信息
点击此处可从《北京航空航天大学学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号