Data reduction and correction algorithm for digital real-time processing of cosmic ray measurements: NM64 monitoring at Dourbes |
| |
Institution: | Royal Meteorological Institute of Belgium, Avenue Circulaire 3, B-1180 Brussels, Belgium |
| |
Abstract: | We present a data correction algorithm for real-time data processing for the NM64 galactic cosmic ray neutron monitor at the Royal Meteorological Institute (RMI) in Dourbes, Belgium. The correction is based on three main tests: a continuity test, tube ratios test and a derivative test. The continuity test works as a high pass filter with a threshold based on the entire recorded dataset. Additionally, it monitors whether the logging takes place at regular intervals (continuously). The ratios test identifies noisy sections and the final derivative test criterion will identify single or double spikes by testing them against the median increase of the intensities. Using these criteria, all data from the cosmic ray station at Dourbes is corrected in real time. Test results have been compared with data from verified neutron monitor stations with a similar geomagnetic cutoff rigidity. |
| |
Keywords: | Cosmic rays Data correction Time series |