A two-dimensional position-sensitive spectroscopic proportional counter for balloon-borne hard X-ray astronomy
Authors:P Ubertini  A Bazzano  L Boccaccini  NA Dipper  L Iafrate  C LaPadula  M Mastropietro  R Patriarca  V Polcaro  ML Urciuoli
Institution:Istituto Astrofisica Spaziale, C.P. 67, 00044 Frascati, Italy
Abstract:A new design of position sensitive spectroscopic proportional counter is described, for use in a balloon borne hard x-ray telescope. Initial position and spectral resolution data from a one-dimensional laboratory prototype are reported. With this device, the final telescope will have an angular resolution of better than 10 minutes of arc.