首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于POD降阶模型的非接触端面密封动态监测原理及仿真
引用本文:张国渊,赵伟刚,闫秀天,陈国定,陈垚.基于POD降阶模型的非接触端面密封动态监测原理及仿真[J].航空学报,2012,33(2):354-361.
作者姓名:张国渊  赵伟刚  闫秀天  陈国定  陈垚
作者单位:1. 西北工业大学机电学院,陕西西安,710072
2. 中国航天科技集团公司西安航天动力研究所,陕西西安,710100
3. 英国思克莱德大学设计制造及工程管理系,英国格拉斯哥G11XJ
基金项目:中国博士后科学基金,航天科技创新基金
摘    要: 端面密封动态性能模型的多维求解复杂性限制了对密封的实时动态监测,为此建立了基于本征正交分解(POD)方法的密封性能求解降阶模型,以获取实时的密封性能特征参数,包括非接触密封微小间隙产生的液膜轴向力及沿着不同方向的液膜力矩.基于降解模型提出了非接触端面密封动态监测的原理,并分析了不同液膜振动频率下的降阶模型的计算误差,完成了对一组不同密封间隙及液膜振动频率下的水润滑端面液膜轴向力及力矩的数值仿真.研究结果表明提出的基于POD降阶模型的非接触端面密封动态监测能达到较高的分析精度,这对于非接触端面密封的动态控制及研究瞬态启动过程中的密封动静特性具有重要的作用.

关 键 词:非接触端面密封  动态监测  本征正交分解方法  液膜力  振动  
收稿时间:2011-05-26;

Principle and Simulation for Real-time Monitoring of the Non-contact Face Seal Based on POD Model
ZHANG Guoyuan , ZHAO Weigang , YAN Xiutian , CHEN Guoding , CHEN Yao.Principle and Simulation for Real-time Monitoring of the Non-contact Face Seal Based on POD Model[J].Acta Aeronautica et Astronautica Sinica,2012,33(2):354-361.
Authors:ZHANG Guoyuan  ZHAO Weigang  YAN Xiutian  CHEN Guoding  CHEN Yao
Institution:Guoding1,CHEN Yao1 1.School of Mechanical Engineering,Northwestern Polytechnical University,Xi’an 710072,China 2.Xi’an Aerospace Propulsion Institute,China Aerospace Science and Technology Corporation,Xi’an 710100,China 3.Department of Design,Manufacture and Engineering Management,University of Strathclyde,Glasgow G11XJ,UK
Abstract:To solve the complex multi-dimensional problem arising in the process of obtaining the real-time performance of a non-contact face seal,a reduced order model based on proper orthogonal decomposition(POD) is proposed.With the model,the dynamic seal performance parameters are computed,including the liquid film force generated by the sealing micro-gap and different directional moments induced by the liquid film.With the POD reduced order model,the principle for the real-time monitoring of the non-contact face seal performance is presented,and the calculation error for different vibration frequencies of axial positions are analyzed.With the principle,a numerical simulation of a water-lubricated non-contacting face seal with different seal gaps and liquid vibration frequencies is implemented,and the liquid film force,torque and their calculation errors are obtained.The results show the high accuracy of the non-contact seal dynamic monitor based on the proposed POD reduced-order model,which will help to promote the level in researching the dynamic control of non-contacting face seals and the static and dynamic performances of seals during the transient start-up stage.
Keywords:non-contacting face seal  real-time monitoring  proper orthogonal decomposition method  liquid film force  vibration
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《航空学报》浏览原始摘要信息
点击此处可从《航空学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号