Effect of baffle injectors on the first-order tangential acoustic mode in a cylindrical combustor
Institution:1. School of Energy and Environmental Engineering, Hebei University of Technology, Tianjin 300401, China;2. Hebei Key Laboratory of Thermal Science and Energy Clean Utilization, Tianjin 300401, China
Abstract:Combustion instability is a very important issue in the development of the propulsion systems used in aerospace. It is very important to associate the high frequency combustion instabilities with the acoustic characteristics of the combustion chamber. In this paper, the effects of various baffle injectors which were installed on the injector faceplate on the first-order tangential acoustic mode were investigated theoretically and experimentally. The effects of the gap between adjacent injectors on the first-order tangential acoustic mode in a cylindrical chamber were considered. The acoustic admittance of the injectors was derived. The results showed that the amplitude and frequency of the first-order tangential acoustic mode increase with the increase in the gap between adjacent injectors, but decrease with the increase in the number and height of the baffles. The baffle injectors have a greater influence on the amplitude and frequency of the first-order tangential acoustic mode than the baffle blades.
Keywords:Baffle injectors  Combustion instability  Cylindrical combustor  Gap between adjacent injectors  Tangential acoustic mode