首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Gyro Misalignment and Encoder Quantization Effects During Multi-Axis Evaluation of Strapdown Gyros
Authors:Scheiman  GE
Institution:Army Inertial Guidance and Control Laboratory U. S. Army Missile Command Redstone Arsenal, Ala. 35809;
Abstract:This paper presents a quantitative discussion of two error sources which affect the accuracy of data comparison between instrument outputs and reference angle computations during multi-axis evaluation of strapdown gyros. The error due to misalignment of gyro input axes is formulated in terms of closed-form solutions for typical relationships between the three table gimbal rotation histories. If the angular positions of the table gimbal axes are measured by shaft encoders, then any measurement has an uncertainty in the range from plus to minus one-half of the quantization level. It is shown that the effect of encoder quantization error on the computer transformed angles in the bodyfixed coordinate system can be divided into two parts: the initial uncertainty of the zero positions of the gimbals before table motion is begun, and all subsequent error contributions during table test. Typical data for gyro misalignment and encoder quantization error effects are presented.