首页 | 本学科首页   官方微博 | 高级检索  
     检索      

海上双馈电机开路故障容错性能评估
引用本文:冯煜尧,张开华,诸浩君,王健,魏书荣,符杨.海上双馈电机开路故障容错性能评估[J].航空动力学报,2017,44(11):111-117.
作者姓名:冯煜尧  张开华  诸浩君  王健  魏书荣  符杨
作者单位:国家电网上海市电力公司电力科学研究院,上海200437,上海绿色环保能源有限公司,上海200433,上海绿色环保能源有限公司,上海200433,上海电力学院 电气工程学院,上海200090,上海电力学院 电气工程学院,上海200090,上海电力学院 电气工程学院,上海200090
基金项目:上海市绿色能源并网工程技术研究中心基金项目(13DZ2251900);上海市科委科技创新项目(14DZ1200905);“电气工程”上海市II类高原学科;上海市电站自动化技术重点实验室基金项目
摘    要:海上风电机组面临故障率高、停运损失大等问题,迫切需要及早发现运行故障、及时提供容错机制。构建基于西蒙决策理论的双馈风力发电机开路故障容错设计方案,选取电能质量和风力发电机组可靠性作为典型评估指标。结合双馈风力发电机组机侧变流器单相开路故障容错案例,给出量化的容错性能指标。结果表明及时有效的故障容错机制能够提高海上风电场的可用率,避免故障恶化,降低故障带来的经济损失。

关 键 词:海上风电    双馈电机    开路故障    容错评估

The Performance Evaluation of OpenCircuit Fault ToleranceOffshore Wind DFIGs
FENG Yuyao,ZHANG Kaihu,ZHU Haojun,WANG Jian,WEI Shurong and FU Yang.The Performance Evaluation of OpenCircuit Fault ToleranceOffshore Wind DFIGs[J].Journal of Aerospace Power,2017,44(11):111-117.
Authors:FENG Yuyao  ZHANG Kaihu  ZHU Haojun  WANG Jian  WEI Shurong and FU Yang
Institution:State Grid Electric Power Research Institute, SMEPC, Shanghai 200437, China,Shanghai Green Environmental Protection Energy Co., Ltd., Shanghai 200433, China,Shanghai Green Environmental Protection Energy Co., Ltd., Shanghai 200433, China,College of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China,College of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China and College of Electrical Engineering, Shanghai University of Electric Power, Shanghai 200090, China
Abstract:Faced with high failure rate and large outage losses, offshore wind farms needed to find operation faults and provided faulttolerant mechanism as soon as possible doublyfed wind generators (DFIGs) opencircuit faulttolerant projects were built based on simon decision theory, which took power quality and wind turbine reliability as typical evaluation standards. The tolerant effect was evaluated combining the example that was doublyfed wind generators rotor side converter single phase open circuit fault. The results showed that timely and effective faulttolerant mechanism could raise availability, avoid fault deterioration and reduce economic losses caused by faults in offshore wind farms.
Keywords:offshore wind power  doublyfed wind generator  opencircuit fault  tolerance evaluation