船用钢需钠弧菌附着腐蚀电化学噪声特征分析
引用本文:范春华李国祥,刘伯洋,吴钱林钟宁,尹衍升.船用钢需钠弧菌附着腐蚀电化学噪声特征分析[J].南京航空航天大学学报,2016,48(1):81-86.
作者姓名:范春华李国祥  刘伯洋  吴钱林钟宁  尹衍升
作者单位:上海海事大学海洋科学与工程学院,上海,201306
摘    要:选取船用钢板DH34为研究对象 ,将试验钢板浸泡于需钠弧菌培养液中和无菌培养液中进行腐蚀试验,对比分析了该材料在需钠弧菌培养液中的腐蚀特征。采用扫描电镜观察腐蚀形貌,结果表明在需钠弧菌培养液中试样发生局部点蚀,而在无菌培养液中则为全面腐蚀。对腐蚀过程进行了噪声电压和噪声电流的采集,时域和频域分析表明:在有需钠弧菌的培养液中,电压噪声功率谱的高频斜率高于-20 dB/dec,截止频率大于0.2 Hz,起始两天噪声的点蚀指数接近于1;而在无菌的培养液中,电压噪声功率谱的高频斜率小于-20 dB/dec,截止频率低于0.2 Hz。需钠弧菌的培养液中噪声电阻值高于无菌培养液中噪声电阻值。点蚀指数、噪声功率谱密度的高频斜率和截止频 率可用于判断需钠弧菌附着时船用钢板DH34的腐蚀行为。

关 键 词:微生物腐蚀  需钠弧菌  电化学噪声

Analysis of Electrochemical Noise Characteristics Arising from Hull Steel Corrosion Induced by Vibrio Natriegens
Fan Chunhu,Li Guoxiang,Liu Boyang,Wu Qianlin,Zhong Ning,Yin Yansheng.Analysis of Electrochemical Noise Characteristics Arising from Hull Steel Corrosion Induced by Vibrio Natriegens[J].Journal of Nanjing University of Aeronautics & Astronautics,2016,48(1):81-86.
Authors:Fan Chunhu  Li Guoxiang  Liu Boyang  Wu Qianlin  Zhong Ning  Yin Yansheng
Institution:Ocean Science and Egnineering College, Shanghai Maritime University, Shanghai, 201306, China
Abstract:The corrosion characteristics of hull steel DH34 exposed in the Vibrio natriegens culture solution and the sterilized culture solution are studied through scanning electron microscope (SEM) and electrochemical noise analysis (ENA). The pitting of hull steel is developed in Vibrio natrigens solution while the general corrosion is developed in sterilized culture solution. ENA results show that the pitting index values are near to 1 on the first two days in Vibrio natriegens culture solution. The slop of potential noise power density spectrum (PDS) on high frequency scale is higher than -20 dB/dec and the cut-off frequency is higher than 0.2 Hz in Vibrio natrigens culture solution, while the slop is lower than -20 dB/dec and the cut-off frequency is lower than 0.2 Hz in sterilized culture solution. The noise resistance in Vibrio natrigens culture solution is higher than that in sterilized culture solution. The pitting index, PDS slop on high frequency scale and cut-off frequency can be applied to the corrosion behavior analysis induced by Vibrio natriegens.
Keywords:microorganism induced corrosion  Vibrio natrigens  electrochemical noise