The measurement of water vapour in thermal emission on studies of nimbus-7 stratoprobe flights for correlative studies of nimbus-7
Authors:WFJ Evans  RS O&#x;Brien
Institution:Atmospheric Environment Service, 4905 Dufferin Street, Downsview, Ontario M3H 5T4, Canada
Abstract:A scanning infrared radiometer used to measure nitric acid was flown on the STRATOPROBE Flight of November 8, 1978. Using the observed thermal emission from 6.5 to 7.4 microns during the balloon ascent, a water vapour profile has been derived using a band model of the water vapour lines in this spectral region. The resulting profile has a minimum of 3.3 ppmv at the tropopause and then rises to a value of 5 ppmv by 30 km. The profile is comparable to the profile from another water vapour instrument from the National Physical Laboratory which was flown on the LIP balloon payload on the same day. A coincident profile from the LIMS experiment on NIMBUS 7 was also obtained since the STRATOPROBE experiment was flown as a correlative measurement for the LIMS experiment.