首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Instrumentation and data systems for high-time resolution study of space plasma shocks
Authors:VM Balebanov  OL Vaisberg  EM Vasiliev  GN Zastenker  VP Evdokimov  EG Eroshenko  LV Pesotski  VF Babkin  S Fisher  Z Nemechek  Ya Shafrankova
Institution:1. Space Research Institute Academy of Sciences U.S.S.R., Moscow, USSR;7. IZMIRAN, Academy of Sciences U.S.S.R., Moscow Region, USSR;71. Astronomical Institute, Czechoslovak Academy of Sciences, Prague, Czechoslovakia;2. Charles University, Prague, Czechoslovakia
Abstract:This paper deals with the principal methods of achieving high-time resolution measurements for the study of fine structure of shocks and other discontinuities in space plasmas. In the measurements of ion energy spectra, we have obtained the time resolution about 1s.In the Soviet-Czechoslovak INTERSHOCK project we will obtain temporal resolution better than 0.1s in the measurement of the main plasma parameters. This will be obtained with the multichannel energy spectrometer and the on-board data acquisition and processing system triggered by the shock signature. This system controls the data sampling rate from some scientific instruments and switches on a high-sampling rate near the shock. The method implies detecting a shock by means of on-board processing of magnetic field and plasma parameters. The algorithm for this detection uses both parameters separately as well as in combinations.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏