Studies of Logarithmic Radar Receiver Using Pulse-Length Discrimination
Authors:Hansen  V G
Institution:SHAPE Technical Centre The Hague, Netherlands;
Abstract:Using a logarithmic amplifier giving a detected output followed by a high-pass filter is a technique for reducing adverse effects of distributed clutter in radar receivers. A pulse-length discriminator (PLD) used as the high-pass filter is treated here. Theoretical and experimental results for the loss in detectability introduced by this receiver, as compared with a matched filter or a good approximation thereto, have been obtained. For the case of single-hit detection, losses of 4 to 8 dB are introduced by the logarithmic amplifier/pulse-length discriminator (LOG AMP/PLD) combination; for post-detection integration, the losses are reduced to 2 to 4 dB. The latter values would apply where the LOG AMP/PLD output is presented on a PPI (plan position indicator). Some experimental results of the ability of the LOG AMP/PLD receiver to reject signals of incorrect pulse length show that signals exceeding the design pulse length by more than 25 to 50 percent are effectively suppressed. No significant short-pulse discrimination is obtained from the receiver.