首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于PIV技术流动调整器性能试验研究
引用本文:王瑞欣,郭亚军,屈鑫鑫,桂淼,毕勤成,高彬.基于PIV技术流动调整器性能试验研究[J].推进技术,2019,40(12):2710-2716.
作者姓名:王瑞欣  郭亚军  屈鑫鑫  桂淼  毕勤成  高彬
作者单位:1.西安建筑科技大学 建筑设备科学与工程学院;2.西安交通大学 动力工程多相流国家重点实验室;3.国家电投集团科学技术研究院有限公司,北京;102209
基金项目:国家自然科学基金 51776167;国家科技重大专项基金 2015ZX06002003国家自然科学基金(51776167);国家科技重大专项基金(2015ZX06002003)。
摘    要:管内流态畸变对压差式流量计的测量精度有较大影响。在流量计的上游安装流动调整器,可以达到改善甚至消除流态畸变、提高测量精度的目的。为了研究流动调整器的整流效果及性能,选取竖直双弯头(90°布置)和半开阀门(50%开度)两种涡发生器来产生流态畸变,采用PIV测速技术,对管束式流动调整器、AMCA调整器和Zanker流动调整器三种流动调整器的整流效果进行实验研究。研究结果表明,相较于无流动调整器情况,三种流动调整器均能明显起到改善流态畸变的作用。其中管束式流动调整器和AMCA调整器可以有效地消除径向速度波动和漩涡流动,而Zanker流动调整器消除速度不对称分布的能力最强,同时带来的压力损失也最大。

关 键 词:流量计  流态畸变  流动调整器  PIV  流动分布
收稿时间:2018/11/22 0:00:00
修稿时间:2019/1/23 0:00:00

Experimental Study on Performance of Flow Conditioners Based on PIV Measurements Technology
WANG Rui-xin,GUO Ya-jun,QU Xin-xin,GUI Miao,BI Qin-cheng,GAO Bin.Experimental Study on Performance of Flow Conditioners Based on PIV Measurements Technology[J].Journal of Propulsion Technology,2019,40(12):2710-2716.
Authors:WANG Rui-xin  GUO Ya-jun  QU Xin-xin  GUI Miao  BI Qin-cheng  GAO Bin
Abstract:The flow distortion in tube has a great impact on the measurement accuracy of the differential pressure flowmeter. A flow conditioner, placed upstream of the flowmeter, can reduce or completely eliminate this flow distortion in practical applications and improve the measurement accuracy of the flowmeter significantly. In this paper,in order to research the rectification effect and performance of the flow conditioners, the performance of three flow conditioners, i.e. tube bundle flow conditioner, AMCA flow conditioner and Zanker flow conditioner, was experimentally studied by advanced PIV technology.Two vortex generators, i.e. 90° configurated double bends and 50% opening value, were selected to produce the flow distortion.The results showed that the flow distortion could be significantly reduced with flow conditioners installed.Tube bundle flow conditioner and AMCA flow conditioner had obvious effects on eliminating the radial velocity fluctuation and vortex flow. Meanwhile, Zanker flow conditioner was found to perform best on offsetting the asymmetrical velocity distribution, while the maximum pressure drop was caused simultaneously.
Keywords:Flowmeter  Flow distortion  Flow conditioner  PIV  Flow distribution
本文献已被 CNKI 等数据库收录!
点击此处可从《推进技术》浏览原始摘要信息
点击此处可从《推进技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号