摘    要:为解决飞行器高马赫数飞行时,用于冷却航空发动机涡轮叶片和其他高温部件的压气机出口空气温度过高的问题,设计加工了一种以外涵空气为冷源的螺旋管式空气-空气换热器用于预先冷却冷却空气。换热器由48根材料为不锈钢321,外径4 mm,壁厚0.5 mm的螺旋管组成,重量1.91 kg,传热面积密度106 m2/m3。在常温工况下实验研究了换热器管内和管外流体的阻力特性,高温条件下试验验证了换热器设计点性能,压气机出口空气温降达188 K,功重比4.9 kW/kg,换热器展现出较强的换热能力。高温条件下实验研究了两侧空气流量分别单独变化时换热器的热动力性能,拟合了管外换热经验关系式。研究结果可用于未来相似结构换热器的设计。

关 键 词:螺旋管  换热器  航空发动机  热防护
收稿时间:2019/10/9 0:00:00
修稿时间:2021/4/8 0:00:00

Design and Experimental Study of Spiral Tube Air-Air Heat Exchanger
LIU Yin-long,FU Yan-chen,WEN Jie,QI Shao-shuai.Design and Experimental Study of Spiral Tube Air-Air Heat Exchanger[J].Journal of Propulsion Technology,2021,42(5):1087-1093.
Authors:LIU Yin-long  FU Yan-chen  WEN Jie  QI Shao-shuai
Institution:College of Energy and Power Engineering,Beihang University,College of Energy and Power Engineering,Beihang University,,
Abstract:To solve the problem that the temperature is too high of the compressor bleeding air used to cool the turbine blades and other high temperature components of the aircraft engine when flying high Mach number, a spiral tube air-air heat exchanger with bypass air as a coolant was designed to pre-cool the cooling air. The heat exchanger consists of 48 pieces of stainless steel 321 spiral tubes with the outer diameter of 4 mm and wall thickness of 0.5 mm. The weight is 1.91 kg and the heat transfer area density is 106 m2/m3. The flow resistance characteristics of the fluid inside and outside the heat exchanger tube were studied experimentally under room temperature conditions. The design point performance of the heat exchanger was verified by the test under high temperature conditions. The temperature drop of the compressor exiting air reached 188 K and the power-to-weight ratio was 4.9 kW/kg, which shows a strong heat transfer ability. Under the high temperature condition, the thermodynamic performance of the heat exchanger was studied experimentally when the air flow on both sides was changed separately, and the empirical correlation for heat transfer coefficient on tube outside was fitted. The research results will be helpful for the design of future similar structure heat exchangers.
Keywords:spiral tube  heat exchanger  aero-engine  thermal protection
点击此处可从《推进技术》浏览原始摘要信息
点击此处可从《推进技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号