首页 | 本学科首页   官方微博 | 高级检索  
     检索      

ICT辅助涡轮叶片内冷通道多余物检测方法
引用本文:杨民,孙晶晶,李兴东,魏东波.ICT辅助涡轮叶片内冷通道多余物检测方法[J].航空动力学报,2011,26(11):2433-2438.
作者姓名:杨民  孙晶晶  李兴东  魏东波
作者单位:1. 北京航空航天大学机械工程及自动化学院,北京,100191
2. 中国计量科学研究院电离辐射与医学工程计量科学研究所,北京,100013
基金项目:国家自然科学基金(60872080,61077011); 国家科技支撑项目(2011BAI02B02)
摘    要:为了实现涡轮叶片内冷通道多余物的无损检测与高精度提取,以工业计算机断层扫描技术为检测手段,基于刚性变换与正弦投影之间的关系,求得待测试件与标准试件断层图像方位上的位移参数,对测试件断层正弦图与标准件对应断层正弦图进行配准,提取出多余物正弦图并重建出多余物断层图像.实验证明该方法能有效识别出叶片内冷通道内的多余物,相比传...

关 键 词:多余物  工业计算机断层扫描(ICT)  涡轮叶片  图像配准  X-射线检测
收稿时间:2010/11/17 0:00:00
修稿时间:2011/6/29 0:00:00

ICT assisted detection for remainders in the internal cooling channel of the turbine blade
YANG Min,SUN Jing-jing,LI Xing-dong and WEI Dong-bo.ICT assisted detection for remainders in the internal cooling channel of the turbine blade[J].Journal of Aerospace Power,2011,26(11):2433-2438.
Authors:YANG Min  SUN Jing-jing  LI Xing-dong and WEI Dong-bo
Institution:YANG Min1,SUN Jing-jing1,LI Xing-dong2,WEI Dong-bo1 (1.School of Mechanical Engineering and Automation,Beijing University of Aeronautics and Astronautics,Beijing 100191,China,2.Division of Metrology in Ionizing Radiation and Medicine,National Institute of Metrology,Beijing 100013,China)
Abstract:In order to detect remainders in the internal cooling channels by non-destructive means with high accuracy,industrial computed tomography was used to scan the tested blade.The position displacement parameters between the tested blade and the standard specimen were calculated base on the rigid transformation and sinogram projection.Then the sinograms of the scanned slice and the corresponding standard slice were matched together in order to extract the sinogram of the remainders and the reconstructed images of them were obtained.The experimental results prove that this method can extract remainders in the internal cooling channels effectively.Compared to the traditional remainder extraction algorithm based on CT(computed tomography) image,the proposed algorithm is realized in the projection domain,and it is rarely affected by projection data incompleteness,scanning system bias and the reconstruction artifacts,so it has a higher accuracy.
Keywords:remainder  industrial computed tomography (ICT)  turbine blade
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《航空动力学报》浏览原始摘要信息
点击此处可从《航空动力学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号