首页 | 本学科首页   官方微博 | 高级检索  
     检索      

复合相变热沉在电子设备热管理中的应用
引用本文:林佳,江兴旺,谭继勇,周振凯.复合相变热沉在电子设备热管理中的应用[J].航天器环境工程,2017,34(2):150-155.
作者姓名:林佳  江兴旺  谭继勇  周振凯
作者单位:中国电子科技集团公司 第二十九研究所, 成都 610000;中国电子科技集团公司 第二十九研究所, 成都 610000;中国电子科技集团公司 第二十九研究所, 成都 610000;中国电子科技集团公司 第二十九研究所, 成都 610000
摘    要:某些特殊电子设备的短时高功耗运行往往会引起急剧温升,进而导致设备失效。文章采用膨胀石墨/高碳醇复合相变材料(PCM)作为热沉,针对某高功耗模块进行了散热仿真,并与传统铝热沉进行了对比,结果表明无主动散热平台下PCM热沉显著优于铝热沉。同工况温箱实验进一步验证相变热沉散热特性,并与仿真结果进行对比,结果表明实验结果与仿真结果具有一致的温度变化趋势,但由于相变温度范围的差异导致不同时间段温升速率不同。分析了二者的差异及原因,为严酷条件下应用相变材料进行热设计和热管理提供参考。

关 键 词:复合相变材料  热管理  电子设备  热沉  仿真分析  实验研究
收稿时间:2016/10/28 0:00:00
修稿时间:2017/3/5 0:00:00

Application of composite PCM in thermal management of electronic equipment
LIN Ji,JIANG Xingwang,TAN Jiyong and ZHOU Zhenkai.Application of composite PCM in thermal management of electronic equipment[J].Spacecraft Environment Engineering,2017,34(2):150-155.
Authors:LIN Ji  JIANG Xingwang  TAN Jiyong and ZHOU Zhenkai
Institution:The 29 th Research Institute of China Electronics Technology Group Corporation, Chengdu 610000, China;The 29 th Research Institute of China Electronics Technology Group Corporation, Chengdu 610000, China;The 29 th Research Institute of China Electronics Technology Group Corporation, Chengdu 610000, China;The 29 th Research Institute of China Electronics Technology Group Corporation, Chengdu 610000, China
Abstract:Some electronic equipment works in short time with high heat flux, which will cause a steep temperature rise that may even lead to equipment failure. In order to solve this problem, the expanded graphite/higher alcohol composite phase change material (PCM) is adopted in a high heat flux module. A comparison between PCM and Al as the heat sink material is made through simulation. It is shown that the PCM heat sink enjoys a superior thermal performance over the Al heat sink in the non-active cooling platform. A thermal experiment under the same condition is conducted to verify the superior thermal performance of the PCM and to make comparison with the simulation results as well. It is shown that both results have the same trend of temperature variation, but specific temperature change rates are observed for different phase change temperatures. The difference between the experiment and the simulation is analyzed, and the results may provide a basis for the thermal design and management using PCM as the heat sink under rigorous conditions.
Keywords:composite PCM  thermal management  electronic equipment  heat sink  simulation analysis  experimental study
本文献已被 CNKI 等数据库收录!
点击此处可从《航天器环境工程》浏览原始摘要信息
点击此处可从《航天器环境工程》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号