‘Good’ events selection efficiency of the scintillation time-of-flight system of the Gamma-1 telescope in the 30–300 MeV energy range |
| |
Authors: | V. A. Grigoriev |
| |
Affiliation: | (1) Moscow Engineering Physics Institute, U.S.S.R. |
| |
Abstract: | The scintillation time-of-flight triggering system of the Gamma-1 gamma-ray telescope provides for both the time-of-flight discrimination and the pulse height discrimination of the secondary particles. The paper gives some experimental results for energy dependence of the instrument efficiency in 30–300 MeV energy range for different trigger logics. |
| |
Keywords: | |