首页 | 本学科首页   官方微博 | 高级检索  
     


High-Speed Homopolar Inductor Alternators of Minimum Leakage Reactance
Authors:Schenk   K.F. Jokl   A.L.
Affiliation:University of Colorado Boulder, Colo.;
Abstract:
The leakage reactance of the machine is expressed as an equation involving slot leakage, end-connection leakage, differential leakage, stator-halves leakage, and tooth-top leakage reactance. This leakage reactance equation, or objective function, is then minimized under suitable constraints. Geometric programming is used to carry through the optimization procedure. A computer program is developed and applied to find the optimum leakage reactance for a 95 kVA, 208 V, wye-connected, 40 800 r/min aerospace alternator, using 8-, 10-, and 12-pole machines.