首页 | 本学科首页   官方微博 | 高级检索  
     检索      

Operating characteristics of a high radius pre-swirl cooling system
作者姓名:P. New  P. R. N. Childs
作者单位:Rolls-Royce supported University Technology Centre in Aero-Thermal Systems University of Sussex,UK,Rolls-Royce supported University Technology Centre in Aero-Thermal Systems,University of Sussex,UK
摘    要:An experimental investigation into pre-swirl effectiveness and receiver hole discharge coefficient characteristics for a high radius injection pre-swirl cooling systems was carried out on a physically representative experimental rig with a 450 mm diameter rotor.The receiver holes and pre-swirl nozzle were located at a radius of 181 mm and 180 mm respectively.The experimental work was mainly conducted at 5 000~12 000 r/min,4 bar absolute pressure and 1.132 kg/s air supply.The maximum air supply temperature was 190 ℃.Pressure and temperature distributions in the pre-swirl system were examined with an emphasis on the velocity effectiveness of the pre-swirl system as a whole and on the discharge coefficients of the rotating 'receiver holes' in the rotor.The results showed that the velocity effectiveness increased with increasing swirl ratio resulting in reduced blade cooling flow temperature.Different seal flow configurations caused very different effectiveness at different speeds,but outflow through the inner and outer seals always gave the highest effectiveness compared other configurations.Increasing the seal flow rate reduced the effectiveness.For the coefficient of discharge,except for the low speed range,it increased with increase in swirl ratio for most speeds.

文章编号:1000-8055(2007)06-0849-10
收稿时间:2006/10/16 0:00:00
修稿时间:2006年10月16

Operating characteristics of a high radius pre-swirl cooling system
P. New,P. R. N. Childs.Operating characteristics of a high radius pre-swirl cooling system[J].Journal of Aerospace Power,2007,22(6):849-858.
Authors:P New and P R N Childs
Abstract:An experimental investigation into pre-swirl effectiveness and receiver hole discharge coefficient characteristics for a high radius injection pre-swirl cooling systems was carried out on a physically representative experimental rig with a 450 mm diameter rotor.The receiver holes and pre-swirl nozzle were located at a radius of 181 mm and 180 mm respectively.The experimental work was mainly conducted at 5000~12000 r/min,4 bar absolute pressure and 1.132 kg/s air supply.The maximum air supply temperature was 190℃.Pressure and temperature distributions in the pre-swirl system were examined with an emphasis on the velocity effectiveness of the pre-swirl system as a whole and on the discharge coefficients of the rotating 'receiver holes'in the rotor.The results showed that the velocity effectiveness increased with increasing swirl ratio resuhing in reduced blade cooling flow temperature.Different seal flow configurations caused very different effectiveness at different speeds,but outflow through the inner and outer seals always gave the highest effectiveness compared other configurations.Increasing the seal flow rate reduced the effectiveness.For the coefficient of discharge,except for the low speed range,it increased with increase in swirl ratio for most speeds.
Keywords:gas turbine  pre-swirl cooling system  high radius  velocity effecitiveness  discharge coefficient
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《航空动力学报》浏览原始摘要信息
点击此处可从《航空动力学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号