三床型机载制氧系统控制设计与实验验证
引用本文:蒋东升,卜雪琴,林贵平,孙兵,黄俊,方玲,赵宏韬.三床型机载制氧系统控制设计与实验验证[J].北京航空航天大学学报,2018,44(8):1603-1608.
作者姓名:蒋东升  卜雪琴  林贵平  孙兵  黄俊  方玲  赵宏韬
作者单位:1.北京航空航天大学 航空科学与工程学院, 北京 100083
摘    要:为解决两床型机载制氧系统在实际应用过程中出现的输出压力波动大及低空氧浓度偏高等问题,需研制与开发三床型机载制氧系统。为此,依据系统控制逻辑,采用电磁阀驱动电控气动阀循环工作的控制模式,开展了三床型机载制氧系统的控制设计,提出了高低空分段调节循环周期的控制方法,并在不同输入压力、流量条件下,对三床型机载制氧系统进行了循环周期实验,探索了产品气氧浓度随循环周期时间的变化规律。研究结果表明:当采用高空循环周期为6 s,低空循环周期为9 s,高低空分段高度为3.5 km等控制参数时,系统控制设计可适用于三床型机载制氧系统,并满足三床型机载制氧系统控制设计的需求。 

关 键 词:三床    机载制氧系统    系统控制    循环周期    实验
收稿时间:2017-12-04

Control design and experimental verification of three-bed onboard oxygen generation system
JIANG Dongsheng,BU Xueqin,LIN Guiping,SUN Bing,HUANG Jun,FANG Ling,ZHAO Hongtao.Control design and experimental verification of three-bed onboard oxygen generation system[J].Journal of Beijing University of Aeronautics and Astronautics,2018,44(8):1603-1608.
Authors:JIANG Dongsheng  BU Xueqin  LIN Guiping  SUN Bing  HUANG Jun  FANG Ling  ZHAO Hongtao
Institution:1.School of Aeronautic Science and Engineering, Beijing University of Aeronautics and Astronautics, Beijing 100083, China2.AVIC Hefei Jianghang Aircraft Equipment Co., Ltd., Hefei 230051, China
Abstract:Two-bed onboard oxygen generation system is facing the problem of large pressure fluctuation of output gas and high oxygen concentration at low altitude during the practical application process. In order to solve these problems, three-bed onboard oxygen generation system needs to be developed. According to the system control logic, the control mode that the electronic controlled pneumatic servo valve worked circularly was adopted. The control design of three-bed onboard oxygen generation system has been proposed. The control method of segmented regulation was proposed, in which different cycle time was applied depending on the altitude. Under different input pressure and flow conditions, the experiments of the three-bed onboard oxygen generation system were performed to investigate the influence of the cycle time on the oxygen concentration of product gas. The study results show that when the cycle time for low altitude and high altitude is determined to be 9 s and 6 s, respectively, and the segmented altitude is determined to be 3.5 km, the system control design is suitable for the three-bed onboard oxygen generation system, and meets the requirements for the control design of three-bed oxygen generation system.
Keywords:three-bed  onboard oxygen generation system  system control  cycle period  experiment