毫米波准光开放腔测试系统误差分析
引用本文:桂勇锋,窦文斌.毫米波准光开放腔测试系统误差分析[J].宇航计测技术,2012,32(5):1-7.
作者姓名:桂勇锋  窦文斌
作者单位:1、东南大学毫米波国家重点实验室,江苏南京 210096
摘    要:给出用于毫米波频段精确测量介质片复介电常数的准光开放腔系统的误差分析,说明了近似理论引起的误差和被测量提取不准引起的误差。推导了相关的公式,给出了分析的数值结果和测量结果。

关 键 词:毫米波  准光开放腔  误差分析  

Errors Analysis of Quasi Optical Open Cavity Measurement System at Millimeter Waves
GUI Yong-feng,DOU Wen-bin.Errors Analysis of Quasi Optical Open Cavity Measurement System at Millimeter Waves[J].Journal of Astronautic Metrology and Measurement,2012,32(5):1-7.
Authors:GUI Yong-feng  DOU Wen-bin
Institution:1、State Key Lab of Millimeter Waves, Southeast University, Nanjing, Jiangsu 210096
Abstract:Errors analysis of quasi optical open cavity, which is used to measure the complex dielectric constant of the dielectric plate accurately, is presented. The errors from the approximating theory and the errors due to the measurement system and measurement process are described. The formulas are deduced, and the simulation results and measurement results are presented.
Keywords:Millimeter waves  Quasi optical open cavity  Errors analysis  